Skip to content

Heart Failure After Heart Transplantation Due to Chronic Rejection

Allograft Vasculopathy and Unexplained Graft Dysfunction During Long-term Follow-up After Heart Transplantation

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03808324
Acronym
AVALON
Enrollment
100
Registered
2019-01-17
Start date
2019-01-31
Completion date
2021-03-31
Last updated
2019-01-17

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cardiac Allograft Vasculopathy, Chronic Rejection of Cardiac Transplant, Graft Dysfunction

Brief summary

This study will investigate the prevalence of allograft vasculopathy and unexplained graft dysfunction during long-term follow-up after heart transplantation. Risk factors as well diagnostic approaches will be investigated.

Detailed description

During long-term follow-up heart transplant recipients are at risk of developing different complications that are likely to affect quality of life and survival. The most common cause of death during the later stages after heart transplantation is cardiac allograft vasculopathy, followed by unexplained graft dysfunction. In this study, advanced imaging techniques will be used to describe the frequency of these two complications, examine possible risk factors and study consequences on functional capacity and quality of life. Further, the investigators will investigate whether it is feasible to screen for these conditions with non-invasive imaging methods. By studying patients that have performed cardiac transplantation between 10 and 20 years ago, the investigators expect to have a significant proportion of patients with these pathological conditions. Methods that will be used include cardiac magnetic resonance imaging, coronary flow velocity reserve assessment, right heart catheterization and coronary imaging with angiography and optical coherence tomography.

Interventions

DIAGNOSTIC_TESTDiagnostic investigations

Participants will undergo tests and diagnostics investigations to identify signs of chronic rejection after heart transplantation.

Sponsors

Sahlgrenska University Hospital
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
PREVENTION
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Heart transplant performed more than 10 years and less than 21 years ago * Scheduled yearly post-transplant control * Signed informed consent

Exclusion criteria

* Estimated GFR \< 30 mL/min/1,73m2 * Radiographic contrast allergy * Severe asthma or COLD with FEV1 \< 50% * Second or third degree AV block * Pregnancy * In the Investigator's opinion, the patient has a clinically significant disease that could be adversely affected by study participation

Design outcomes

Primary

MeasureTime frameDescription
Degree of stenosis in coronary arteries4 hoursCoronary angiography gives information about the degree of stenosis in the coronary arteries. In connection with the angiography Optical Coherence Tomography (OCT) will be performed. A precise measurement and characterization of the intima can be performed by OCT.
Restrictive allograft hemodynamics2 hoursRight heart catheterization will be performed using a Swan-Ganz pulmonary artery thermodilution catheter. Right atrial pressure (RAP), mean pulmonary artery pressure (MPAP), pulmonary capillary wedge pressure (PCWP) and mean arterial pressure (MAP). Cardiac output (CO) and cardiac index (CI) will be recorded by thermodilution. The transpulmonary gradient (TPG) is obtained by subtracting PCWP from MPAP and PVR (in Wood units (WU) by dividing TPG by CO. Measurement will be performed both at rest and after supine bicycle exercise. A restrictive allograft filling pattern will be defined as PCW at rest exceeding 15 mmHg and/or exceeding 25 mmHg during exercise.
Functional assessment of the microvasculature2 hoursCoronary flow reserve (CRF) measurements may provide functional assessment of the microvasculature. Coronary blood flow velocity (CBFV) is measured in the left anterior descending coronary artery (LAD) before, and during constant adenosine infusion using conventional color Doppler ultrasound equipped with coronary imaging protocol. Mid-distal LAD segment is visualized using high frequency color Doppler (\>3 MHz) in the anterior interventricular sulcus. A CINE-loop is then stored to document the 2-D image of LAD. Thereafter spectral Doppler is used to record CBFV. Mean diastolic flow velocity is calculated by manually tracing the diastolic flow velocity signal. Baseline CBFV values are calculated using the mean value of three representative heart beats during resting condition. The mean hyperemic CBFV is calculated as the mean of the three highest CBFV values recorded during the whole infusion period. The ratio between hyperemic and baseline CBFV is defined as CFR.
Degree of myocardial fibrosis4 hoursMeasurement of myocardial T1 times (T1 mapping) with gadolinium-enhanced inversion recovery-prepared sequences may depict diffuse myocardial fibrosis and has good correlation with ex vivo fibrosis content. T1 mapping calculates myocardial T1 relaxation times with image-based signal intensities and will be performed with standard cardiac MR imagers and radiologic workstations.

Countries

Sweden

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026