Skip to content

Adenoma Detection Rate With a New Pediatric Colonoscope With a Short Turn Radius (Pentax Retroview) Compared With a Standard Pentax Pediatric Colonoscope

Adenoma Detection Rate With a New Pediatric Colonoscope With a Short Turn Radius (Pentax Retroview) Compared With a Standard Pentax Pediatric Colonoscope

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03807089
Enrollment
283
Registered
2019-01-16
Start date
2014-07-01
Completion date
2017-05-11
Last updated
2019-07-16

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Colonoscopy

Keywords

Colonoscopy, colon cancer screening

Brief summary

The purpose of this study is to determine whether the new colonoscope that provides both a traditional and a retrograde view (bending 180 degrees to look behind itself) of the colon can detect more polyps than a standard colonoscope that only provides a forward-facing view. The investigators wish to effectively demonstrate the utility of the new colonoscope (Pentax Retroview Colonoscope) as the objective of this study is to determine polyp and adenoma detection rates in human subjects undergoing colonoscopy for polyp surveillance.

Interventions

DEVICEConventional Pediatric Colonoscope
DEVICEShort-Turn Radius Colonoscope

Sponsors

Pentax Medical
CollaboratorINDUSTRY
Massachusetts General Hospital
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
PREVENTION
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
40 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Ability to provide Informed Consent * Age \> 40 * Surveillance Colonoscopy (History of Adenomas)

Exclusion criteria

* Poor or Fair Bowel Prep * Difficult First Insertion * Familial Polyposis * Inflammatory Bowel Disease * Pregnancy * Active GI Bleeding * Prior colonic or rectal resection * Conserved Sattus * Colonoscopy less than 3 years ago * Screening Colonoscopy * Colonoscopy done to evaluate systems like abdominal pain, diarrhea, constipation, change in bowel habits

Design outcomes

Primary

MeasureTime frameDescription
Percentage of Patients With At Least One Adenoma1 hourCompare adenoma detection rate between patients undergoing a colonoscopy with Pentax Retroview colonoscope and pediatric colonoscope.

Secondary

MeasureTime frameDescription
Overall Polyp Detection Rate1 hourCompare polyp detection rate (percent of patients with at least one polyp detected) between patients undergoing a colonoscopy with Pentax Retroview colonoscope and pediatric colonoscope.
Mean Number of Adenomas Identified Per Patient With Polyps1 hourCompare average number of adenomas found per patient with polyps between patients undergoing a colonoscopy with Pentax Retroview colonoscope and pediatric colonoscope.

Other

MeasureTime frameDescription
Size of Polyps Detected1 hourPolyp size was estimated prior to polypectomy by comparing the polyp with objects of known dimension (biopsy forceps, polypectomy snares).
Size of Adenomas Detected1 hour

Participant flow

Pre-assignment details

89 subjects were excluded (poor bowel preparation \[n = 45\], prior colonic resection \[n = 3\], difficult first insertion \[n=45\], not over 40 \[n = 1\], no history of adenomatous colorectal polyps \[n = 1\], device related reasons \[n = 1\])

Participants by arm

ArmCount
Short-Turn Radius Colonoscope
Colonoscopy performed with Short-Turn Radius Colonoscope. The colonoscope will provide a forward-facing view of the colon during advancement to the cecum (standard of care). The scope will then be withdrawn all the way to the rectum and the colon will be inspected using the forward-facing view (standard of care). The colonoscope will then be re-advanced to the cecum and be withdrawn using the retrograde view. Short-Turn Radius Colonoscope
101
Conventional Pediatric Colonoscope
Colonoscopy will be performed with a conventional pediatric colonoscope. During withdrawal, the colon will be inspected using the forward-facing view (standard of care). The colonoscope will then be re-advanced to the cecum and again withdrawn using the forward-facing view. Conventional Pediatric Colonoscope
93
Total194

Baseline characteristics

CharacteristicConventional Pediatric ColonoscopeTotalShort-Turn Radius Colonoscope
Age, Continuous65.8 years
STANDARD_DEVIATION 8.38
65.9 years
STANDARD_DEVIATION 8.2
66.2 years
STANDARD_DEVIATION 8.13
Race and Ethnicity Not Collected0 Participants
Region of Enrollment
United States
93 participants194 participants101 participants
Sex: Female, Male
Female
59 Participants118 Participants59 Participants
Sex: Female, Male
Male
34 Participants76 Participants42 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
0 / 1010 / 93
other
Total, other adverse events
0 / 1010 / 93
serious
Total, serious adverse events
0 / 1010 / 93

Outcome results

Primary

Percentage of Patients With At Least One Adenoma

Compare adenoma detection rate between patients undergoing a colonoscopy with Pentax Retroview colonoscope and pediatric colonoscope.

Time frame: 1 hour

ArmMeasureValue (COUNT_OF_PARTICIPANTS)
Short-Turn Radius ColonoscopePercentage of Patients With At Least One Adenoma63 Participants
Conventional Pediatric ColonoscopePercentage of Patients With At Least One Adenoma68 Participants
Secondary

Mean Number of Adenomas Identified Per Patient With Polyps

Compare average number of adenomas found per patient with polyps between patients undergoing a colonoscopy with Pentax Retroview colonoscope and pediatric colonoscope.

Time frame: 1 hour

ArmMeasureValue (MEAN)Dispersion
Short-Turn Radius ColonoscopeMean Number of Adenomas Identified Per Patient With Polyps2.48 Number of Adenomas Per PatientStandard Deviation 2.05
Conventional Pediatric ColonoscopeMean Number of Adenomas Identified Per Patient With Polyps2.50 Number of Adenomas Per PatientStandard Deviation 1.56
Secondary

Overall Polyp Detection Rate

Compare polyp detection rate (percent of patients with at least one polyp detected) between patients undergoing a colonoscopy with Pentax Retroview colonoscope and pediatric colonoscope.

Time frame: 1 hour

ArmMeasureValue (COUNT_OF_PARTICIPANTS)
Short-Turn Radius ColonoscopeOverall Polyp Detection Rate72 Participants
Conventional Pediatric ColonoscopeOverall Polyp Detection Rate78 Participants
Other Pre-specified

Size of Adenomas Detected

Time frame: 1 hour

ArmMeasureValue (MEAN)Dispersion
Short-Turn Radius ColonoscopeSize of Adenomas Detected5.15 mmStandard Deviation 3.04
Conventional Pediatric ColonoscopeSize of Adenomas Detected4.69 mmStandard Deviation 2.4
Other Pre-specified

Size of Polyps Detected

Polyp size was estimated prior to polypectomy by comparing the polyp with objects of known dimension (biopsy forceps, polypectomy snares).

Time frame: 1 hour

ArmMeasureValue (MEAN)Dispersion
Short-Turn Radius ColonoscopeSize of Polyps Detected4.89 mmStandard Deviation 2.92
Conventional Pediatric ColonoscopeSize of Polyps Detected4.50 mmStandard Deviation 2.3

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026