Skip to content

visuALL Field Analyzer (vFA) Compared to Standard Humphrey Automated Perimetry

How Does the visuALL Field Analyzer (vFA) Compare to Standard Automatic Perimetry (SAP) in Patients With Mild and Moderate Chronic Open Angle Glaucoma (COAG) and Subjects Without Eye Problems?

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03804684
Enrollment
72
Registered
2019-01-15
Start date
2019-01-08
Completion date
2020-10-20
Last updated
2022-06-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Glaucoma, Open-Angle

Keywords

open angle glaucoma, visual field, Standard Automatic Perimetry

Brief summary

To determine age-adjusted reference values of the visuALL Field Analyzer (vFA) retinal sensitivity and to assess the repeatability of the measured values and compare them with those measured by a Standard Automatic Perimetry (SAP).

Detailed description

Standard Automatic Perimetry (SAP) is the gold standard test for the evaluation of central and peripheral retinal sensitivity to light for detection and monitoring optic nerve diseases such as glaucoma. The current device has its own limitation such as positioning for the duration of the test which makes is hard for older patients especially those with back or other musculoskeletal diseases, artifact of the corrective lenses used to accommodate the patients refractive errors, etc. Several devices have been developed since the advent of the Octopus Perimeter 3-5 and the Humphrey Field Analyzer (HFA), in an effort to improve the test reliability and patient comfort. The main goal of this study is to evaluate the repeatability of a novel psychophysical platform that takes advantage of a Head Mounted Device (HMD) with eye tracking capabilities. Other objectives of this study include the development of an initial reference database and comparison of the measured parameters with HFA.

Interventions

Standard Automatic Perimetry (SAP) Humphrey Field Analyzer (HFA) 24-2, Swedish Interactive Threshold Algorithm (SITA) Standard Strategy measures peripheral and central vision in an ophthalmic setting.

DIAGNOSTIC_TESTvisuALL Field Analyzer

visuALL Field Analyzer a new portable hardware and software virtual reality system measures peripheral and central vision to improve early detection of glaucoma damage in a non ophthalmic setting.

Sponsors

Olleyes, Inc.
CollaboratorINDUSTRY
Wills Eye
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
PARALLEL
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
21 Years to 80 Years
Healthy volunteers
Yes

Inclusion criteria

* age 21 to 80 years * Healthy subjects with no eye diseases, normal appearing optic nerve and retina, intraocular pressure less than 19 millimeters mercury and normal standard automatic perimetry (SAP). * mild glaucoma subjects with less than -6 mean deviation * moderate glaucoma subjects with -6 to -12 mean deviation

Exclusion criteria

* spherical refraction outside ± 3.0 diopters and cylinder correction outside 2.0 diopters * Unreliable SAP (false positives, fixation losses and false negatives greater than 25% and/or observable testing artifacts) * Unreliable visuALL Field Analyzer (vFA) (greater than 25% false positive, excessive fixation losses) * SAP abnormality with pattern loss consistent with neurologic and/or other ocular diseases than glaucoma * Intraocular surgery in study eye (except non-complicated cataract or refractive surgery performed more than 6 months before enrollment and without posterior capsule opacification) * History of systemic condition known to affect visual function * History of medication known to affect visual function

Design outcomes

Primary

MeasureTime frameDescription
Mean Retinal Sensitivity From Two Machinesthree hoursMean (Average) retinal sensitivity to light as measured in decibels in multiple spots across the central and peripheral retina (entire visual field). Higher numbers translate to dimmer light which when detected means better vision.
Global Correlation (Agreement Between Two Machines in the Overall Visual Field)three hoursCorrelation (Agreement) between Humphrey Visual Field and VisuALL retinal sensitivity as measured by mean deviation (light measurement in decibels) in multiple spots across the central and peripheral retina (entire visual field). This is the amount of agreement of the measure threshold, which is the lowest level of light detected in different points across the visual field (overall), between two testing machines.

Secondary

MeasureTime frameDescription
Inferior Nasal Quadrant Correlation (Agreement Between Two Machines in the Inferior Nasal Visual Field)three hoursCorrelation (Agreement) between Humphrey Visual Field and VisuALL retinal sensitivity as measured by mean deviation (light measurement in decibels) in multiple spots across the inferior nasal visual field. This is the amount of agreement of the measure threshold, which is the lowest level of light detected in different points across the inferior (lower) nasal portion of the visual field, between two testing machines.
Superior Hemifield Correlation (Agreement Between Two Machines in the Superior Hemifield Visual Fieldthree hoursCorrelation (Agreement) between Humphrey Visual Field and VisuALL retinal sensitivity as measured by mean deviation (light measurement in decibels) in multiple spots across the superior (upper) hemifield portion of the visual field. This is the amount of agreement of the measure threshold, which is the lowest level of light detected in different points across the visual field in the superior hemifield, between two testing machines.

Countries

United States

Participant flow

Pre-assignment details

Glaucoma patients with mild or moderate visual field loss and subjects with healthy vision were enrolled to form two groups for comparison of two methods of visual field testing. Subjects unable to perform testing or test reliability did not meet inclusion criteria in 3 of the Healthy Controls and 18 of the Glaucoma Group. Therefore, 21 participants were excluded from results.

Participants by arm

ArmCount
Healthy Controls
Healthy subjects between 21 and 80 years of age with no eye diseases. Eyes will have normal appearing optic nerve and retina, intraocular eye pressure less than 19 millimeters of mercury, normal, reliable standard automatic perimetry and spherical refraction less than 3 diopters and cylinder correction equal to 2 diopters or less. All subjects will perform Standard Automatic Perimetry Humphrey Field Analyzer and visuALL Field Analyzer to measure peripheral and central visual field. Standard Automatic Perimetry Humphrey Field Analyzer: Standard Automatic Perimetry (SAP) Humphrey Field Analyzer (HFA) 24-2, Swedish Interactive Threshold Algorithm (SITA) Standard Strategy measures peripheral and central vision in an ophthalmic setting. visuALL Field Analyzer: visuALL Field Analyzer a new portable hardware and software virtual reality system measures peripheral and central vision to improve early detection of glaucoma damage in a non ophthalmic setting.
28
Healthy Controls
Healthy subjects between 21 and 80 years of age with no eye diseases. Eyes will have normal appearing optic nerve and retina, intraocular eye pressure less than 19 millimeters of mercury, normal, reliable standard automatic perimetry and spherical refraction less than 3 diopters and cylinder correction equal to 2 diopters or less. All subjects will perform Standard Automatic Perimetry Humphrey Field Analyzer and visuALL Field Analyzer to measure peripheral and central visual field. Standard Automatic Perimetry Humphrey Field Analyzer: Standard Automatic Perimetry (SAP) Humphrey Field Analyzer (HFA) 24-2, Swedish Interactive Threshold Algorithm (SITA) Standard Strategy measures peripheral and central vision in an ophthalmic setting. visuALL Field Analyzer: visuALL Field Analyzer a new portable hardware and software virtual reality system measures peripheral and central vision to improve early detection of glaucoma damage in a non ophthalmic setting.
50
Glaucoma Group
Subjects between 21 and 80 years of age with Mild and Moderate Glaucoma. Eyes will have reliable standard automatic perimetry with no more than -6 mean deviation (mild glaucoma) and between -6 mean and -12 mean deviation (moderate glaucoma); and spherical refraction less than 3 diopters and cylinder correction equal to 2 diopters or less. All subjects will perform Standard Automatic Perimetry Humphrey Field Analyzer and visuALL Field Analyzer to measure peripheral and central visual field. Standard Automatic Perimetry Humphrey Field Analyzer: Standard Automatic Perimetry (SAP) Humphrey Field Analyzer (HFA) 24-2, Swedish Interactive Threshold Algorithm (SITA) Standard Strategy measures peripheral and central vision in an ophthalmic setting. visuALL Field Analyzer: visuALL Field Analyzer a new portable hardware and software virtual reality system measures peripheral and central vision to improve early detection of glaucoma damage in a non ophthalmic setting.
44
Glaucoma Group
Subjects between 21 and 80 years of age with Mild and Moderate Glaucoma. Eyes will have reliable standard automatic perimetry with no more than -6 mean deviation (mild glaucoma) and between -6 mean and -12 mean deviation (moderate glaucoma); and spherical refraction less than 3 diopters and cylinder correction equal to 2 diopters or less. All subjects will perform Standard Automatic Perimetry Humphrey Field Analyzer and visuALL Field Analyzer to measure peripheral and central visual field. Standard Automatic Perimetry Humphrey Field Analyzer: Standard Automatic Perimetry (SAP) Humphrey Field Analyzer (HFA) 24-2, Swedish Interactive Threshold Algorithm (SITA) Standard Strategy measures peripheral and central vision in an ophthalmic setting. visuALL Field Analyzer: visuALL Field Analyzer a new portable hardware and software virtual reality system measures peripheral and central vision to improve early detection of glaucoma damage in a non ophthalmic setting.
52
Total174

Withdrawals & dropouts

PeriodReasonFG000FG001
Overall StudySubjects unable to perform testing or test reliability did not meet inclusion criteria.318

Baseline characteristics

CharacteristicHealthy ControlsTotalGlaucoma Group
Age, Categorical
<=18 years
0 Participants0 Participants0 Participants
Age, Categorical
>=65 years
8 Participants29 Participants21 Participants
Age, Categorical
Between 18 and 65 years
20 Participants43 Participants23 Participants
Ethnicity (NIH/OMB)
Hispanic or Latino
3 Participants3 Participants0 Participants
Ethnicity (NIH/OMB)
Not Hispanic or Latino
25 Participants69 Participants44 Participants
Ethnicity (NIH/OMB)
Unknown or Not Reported
0 Participants0 Participants0 Participants
Mild to Moderate Glaucoma0 Participants44 Participants44 Participants
Number of eyes analyzed
eyes with mild visual field defects
0 number of eyes36 number of eyes36 number of eyes
Number of eyes analyzed
eyes with moderate visual field defects
0 number of eyes13 number of eyes13 number of eyes
Number of eyes analyzed
eyes with severe visual field defects
0 number of eyes3 number of eyes3 number of eyes
Number of eyes analyzed
total eyes analyzed
50 number of eyes102 number of eyes52 number of eyes
Race (NIH/OMB)
American Indian or Alaska Native
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Asian
1 Participants1 Participants0 Participants
Race (NIH/OMB)
Black or African American
10 Participants34 Participants24 Participants
Race (NIH/OMB)
More than one race
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Unknown or Not Reported
0 Participants0 Participants0 Participants
Race (NIH/OMB)
White
17 Participants37 Participants20 Participants
Region of Enrollment
United States
28 participants72 participants44 participants
Sex: Female, Male
Female
18 Participants39 Participants21 Participants
Sex: Female, Male
Male
10 Participants33 Participants23 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
0 / 280 / 44
other
Total, other adverse events
0 / 280 / 44
serious
Total, serious adverse events
0 / 280 / 44

Outcome results

Primary

Global Correlation (Agreement Between Two Machines in the Overall Visual Field)

Correlation (Agreement) between Humphrey Visual Field and VisuALL retinal sensitivity as measured by mean deviation (light measurement in decibels) in multiple spots across the central and peripheral retina (entire visual field). This is the amount of agreement of the measure threshold, which is the lowest level of light detected in different points across the visual field (overall), between two testing machines.

Time frame: three hours

Population: The overall mean retinal sensitivity (lowest level of light detected) measured by two perimetry machines was compared in both normal and glaucoma subjects. This is the difference between the results of the two machines for healthy and glaucoma eyes across their visual field (overall).

ArmMeasureValue (MEAN)
Healthy ControlsGlobal Correlation (Agreement Between Two Machines in the Overall Visual Field)0.5 decibels
Glaucoma GroupGlobal Correlation (Agreement Between Two Machines in the Overall Visual Field)0.8 decibels
Primary

Mean Retinal Sensitivity From Two Machines

Mean (Average) retinal sensitivity to light as measured in decibels in multiple spots across the central and peripheral retina (entire visual field). Higher numbers translate to dimmer light which when detected means better vision.

Time frame: three hours

ArmMeasureGroupValue (MEAN)Dispersion
Healthy ControlsMean Retinal Sensitivity From Two MachinesGlobal field from Humphrey Visual Field29.9 decibelsStandard Deviation 1.4
Healthy ControlsMean Retinal Sensitivity From Two MachinesGlobal field from VisuALL28.7 decibelsStandard Deviation 1.3
Healthy ControlsMean Retinal Sensitivity From Two MachinesInferior nasal quadrant from Humphrey Visual Field30.3 decibelsStandard Deviation 1.3
Healthy ControlsMean Retinal Sensitivity From Two MachinesInferior nasal quadrant from VisuALL28.7 decibelsStandard Deviation 1.6
Healthy ControlsMean Retinal Sensitivity From Two MachinesSuperior hemifield from Humphrey Visual Field29.5 decibelsStandard Deviation 1.5
Healthy ControlsMean Retinal Sensitivity From Two MachinesSuperior hemifield from VisuALL28.6 decibelsStandard Deviation 1.6
Glaucoma GroupMean Retinal Sensitivity From Two MachinesSuperior hemifield from Humphrey Visual Field23.7 decibelsStandard Deviation 5
Glaucoma GroupMean Retinal Sensitivity From Two MachinesGlobal field from Humphrey Visual Field24.8 decibelsStandard Deviation 3.9
Glaucoma GroupMean Retinal Sensitivity From Two MachinesInferior nasal quadrant from VisuALL23.3 decibelsStandard Deviation 6.9
Glaucoma GroupMean Retinal Sensitivity From Two MachinesGlobal field from VisuALL22.9 decibelsStandard Deviation 4.9
Glaucoma GroupMean Retinal Sensitivity From Two MachinesSuperior hemifield from VisuALL21.8 decibelsStandard Deviation 6.5
Glaucoma GroupMean Retinal Sensitivity From Two MachinesInferior nasal quadrant from Humphrey Visual Field24.8 decibelsStandard Deviation 5.8
Secondary

Inferior Nasal Quadrant Correlation (Agreement Between Two Machines in the Inferior Nasal Visual Field)

Correlation (Agreement) between Humphrey Visual Field and VisuALL retinal sensitivity as measured by mean deviation (light measurement in decibels) in multiple spots across the inferior nasal visual field. This is the amount of agreement of the measure threshold, which is the lowest level of light detected in different points across the inferior (lower) nasal portion of the visual field, between two testing machines.

Time frame: three hours

Population: The overall mean retinal sensitivity (lowest level of light detected) measured by two perimetry machines was compared in both normal and glaucoma subjects. This is the difference between the results of the two machines for healthy and glaucoma eyes across their inferior nasal visual field).

ArmMeasureValue (MEAN)
Healthy ControlsInferior Nasal Quadrant Correlation (Agreement Between Two Machines in the Inferior Nasal Visual Field)0.3 decibels
Glaucoma GroupInferior Nasal Quadrant Correlation (Agreement Between Two Machines in the Inferior Nasal Visual Field)0.8 decibels
Secondary

Superior Hemifield Correlation (Agreement Between Two Machines in the Superior Hemifield Visual Field

Correlation (Agreement) between Humphrey Visual Field and VisuALL retinal sensitivity as measured by mean deviation (light measurement in decibels) in multiple spots across the superior (upper) hemifield portion of the visual field. This is the amount of agreement of the measure threshold, which is the lowest level of light detected in different points across the visual field in the superior hemifield, between two testing machines.

Time frame: three hours

Population: The mean retinal sensitivity (lowest level of light detected) measured by two perimetry machines was compared in both normal and glaucoma subjects. This is the difference between the results of the two machines for healthy and glaucoma eyes across the superior hemifield portion of their visual field.

ArmMeasureValue (MEAN)
Healthy ControlsSuperior Hemifield Correlation (Agreement Between Two Machines in the Superior Hemifield Visual Field0.4 decibels
Glaucoma GroupSuperior Hemifield Correlation (Agreement Between Two Machines in the Superior Hemifield Visual Field0.6 decibels

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026