Skip to content

Cardiac Strains for Optimization of CRT in Non-Responders

Use of Cardiac Strains for Optimization of Cardiac Resynchronization Therapy in Non-Responders

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03803826
Enrollment
50
Registered
2019-01-15
Start date
2016-01-01
Completion date
2019-12-01
Last updated
2022-12-07

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Chronic Heart Failure

Keywords

cardiac resynchronization therapy, non-responders

Brief summary

The aim of this study is to investigate the possibility of optimizing the performance of CRT-D in non-responding patients through utilization of cardiac strain speckle tracking

Detailed description

In approximately 30% of patients, cardiac resynchronization therapy (CRT) fails to lead to any improvement of the patients' status. In this study, an investigation of a possible method of optimization through speckle tracking of cardiac strains is attempted. Patients not responding to Cardiac Resynchronization Therapy-Defibrillators (CRT-D) after 3 months are randomly divided into control and intervention groups. Atrioventricular interval is adjusted so that E and A waves do not overlap and the interventricular interval subsequently optimized to yield maximum improvement of the sum of longitudinal+radial+circumferential strains. The left ventricular ejection fraction (LVEF) and NYHA (New York Heart Association Classification improvement 3 months after optimization are evaluated and use of other strain combinations assessed.

Interventions

DEVICECRT-D re-programming

The previously implanted, ineffective CRT-D is reprogrammed under supervision of Trans-Thoracic Echocardiography (TTE) to: 1. adjust the atrioventricular interval so that E and A waves do not overlap 2. the interventricular interval is subsequently optimized to yield maximum improvement of the sum of longitudinal+radial+circumferential strains.

This intervention relates to the determination of strains and atrioventricular interval and supplies data for reprogramming the ineffective CRT-D Transthoracic echocardiography performed to determine the left ventricular ejection fraction as an outcome measure is not considered intervention here (as it is also performed in the control group and that would cause an error cross-referencing.

Sponsors

University Hospital Ostrava
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Intervention model description

Patients not responding to Cardiac Resynchronization Therapy-Defibrillators (CRT-D) after 3 months from implementation are randomly divided into control and intervention groups. Atrioventricular interval is adjusted so that E and A waves do not overlap, the interventricular interval iss subsequently optimized to yield maximum improvement of the sum of longitudinal+radial+circumferential strains. The left ventricular ejection fraction (LVEF) and NYHA (New York Heart Association Classification improvement 3 months after optimization are evaluated and the use of other strain combinations assessed.

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* patients with symptomatic heart failure with NYHA III/IV, pharmacological treatment options exhausted, LVEF below 30%, and QRS duration over 130ms who did not respond to the implantation of CRT-D

Exclusion criteria

* Age below 18 * response to the original CRT implantation

Design outcomes

Primary

MeasureTime frameDescription
Change in the left ventricular ejection fraction6 months from CRT-D implantation, 3 months from optimizationLeft ventricular ejection fraction measured by transthoracic echocardiography prior to optimizing and during a follow-up examination three month after optimizing

Secondary

MeasureTime frameDescription
Change in NYHA Classification6 months from CRT-D implantation, 3 months from optimizationNYHA (New York Heart Association Classification measured using the standard NYHA range I to IV - I being the best result, IV the worst) was evaluated using a standard NYHA questionnaire before optimization and 3 months after optimization during a follow-up examination

Countries

Czechia

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026