Determining the Benefits of Improving Communication in BPAP/CPAP Users

Determining the Benefits of Improving Communication in BPAP/CPAP Users

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03795753
Enrollment
36
Registered
2019-01-08
Start date
2019-03-22
Completion date
2019-07-08
Last updated
2020-09-18

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Communication, Positive-Pressure Respiration

Keywords

Emphysema, Chronic obstructive pulmonary disease, Obstructive sleep apnea

Brief summary

The purpose of this study is to determine the effectiveness of a non-invasive communication aid for BPAP/CPAP masks. This study also looks to determine the potential impact of the device on patients with obstructive sleep apnea (OSA) and the individuals that interact with the device.

Detailed description

Noninvasive positive pressure ventilation (NIPPV) is a crucial tool used to treat respiratory distress and failure, especially when patients have acute worsening (also called exacerbations) of emphysema or chronic obstructive pulmonary disease (COPD). This study will randomize patients who use Noninvasive positive pressure ventilation (NIPPV) to a control (non-functioning) and intervention (functioning) device to determine how well speech can be understood while wearing the device. The purpose of this study is to determine the effectiveness of a non-invasive communication aid for BPAP/CPAP masks. This study also looks to determine the potential impact of the device on patients with obstructive sleep apnea (OSA) and the individuals that interact with the device.

Interventions

DEVICEF2S Communicator

The communicator will be attached to the BPAP/CPAP mask. The study coordinator will ENABLE the communicator. A list of single words and 5-word through 15-word sentences will be provided to the patient. Each single word may be read aloud up to two times. The partner must then select the read word out of a list of twelve possible words. Each sentence may be read aloud up to two times. The partner must transcribe each sentence on a standardized form. A survey will be provided to evaluate the mask on, communicator on period.

OTHERNon-functioning Communicator

The communicator will be attached to the BPAP/CPAP mask. The study coordinator will DISABLE the communicator. A list of single words and 5-word through 15-word sentences will be provided to the patient. Each single word may be read aloud up to two times. The partner must then select the read word out of a list of twelve possible words. Each sentence may be read aloud up to two times. The partner must transcribe each sentence on a standardized form. A survey will be provided to evaluate the mask on, communicator on period.

Sponsors

Emory University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
SINGLE (Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patients must be receiving BPAP/CPAP therapy in the outpatient setting (e.g. clinics, sleep centers).

Exclusion criteria

* Intubated or have a tracheostomy. * Vulnerable populations (children, pregnant women, decisionally impaired adults, and prisoners). * Speech disabilities, reading disabilities, dyslexia.

Design outcomes

Primary

MeasureTime frameDescription
Accuracy of Single Word Selection (Proportion of Right Words From Total)Mask on-communicator on-20 minutesData will be collected using audio recording - accuracy of single word selection (spoken by patient -\> selected by partner). The communicator will be attached to the BPAP/CPAP mask. A list of single words will be provided to the patient. Each single word may be read aloud by patient up to two times. The partner must then select the read word out of a list of twelve possible words.
Accuracy of Sentence Selection (Proportion of Right Sentences From Total)Mask on-communicator on-20 minutesData will be collected using audio recording - accuracy of sentence selection (spoken by patient -\> transcribed by partner). The communicator will be attached to the BPAP/CPAP mask. A list of 5-word through 15-word sentences will be provided to the patient. Each sentence may be read aloud by patient up to two times. The partner must transcribe each sentence on a standardized form.

Secondary

MeasureTime frameDescription
Speech Transmission Index (STI)Mask on with communicator on (20 min)STI is a numeric representation measure of communication channel characteristics whose value varies from 0 = bad to 1 = excellent.On this scale, an STI of at least 0.5 is desirable for most applications.
Number of Subjects That Found That the Device Significantly Improved Noninvasive Ventilation (NIV) ComfortMask on-communicator on-20 minutesNumber of subjects that found that the device significantly improved noninvasive ventilation (NIV) comfort was calculated and reported. Assessment of noninvasive ventilation (NIV) comfort was conducted using Likert Scale Score on clarity of communication on a symmetric seven-level agree-disagree scale.

Countries

United States

Participant flow

Participants by arm

ArmCount
F2S Communicator
The F2S Communication System is a communication aid for use with a noninvasive ventilation (NIV) mask covering at least the mouth. It is a two-component system consisting of (1) a disposable, single patient use patch and signal cable and (2) a reusable communicator with power cable.The non-invasive aid for patients receiving BPAP/CPAP therapy delivers communication between the patient and medical personnel. F2S Communicator: The communicator will be attached to the BPAP/CPAP mask. The study coordinator will ENABLE the communicator. A list of single words and 5-word through 15-word sentences will be provided to the patient. Each single word may be read aloud up to two times. The partner must then select the read word out of a list of twelve possible words. Each sentence may be read aloud up to two times. The partner must transcribe each sentence on a standardized form. A survey will be provided to evaluate the mask on, communicator on period.
23
Non-functioning Communicator
Non-functioning study communication device is used. Non-functioning Communicator: The communicator will be attached to the BPAP/CPAP mask. The study coordinator will DISABLE the communicator. A list of single words and 5-word through 15-word sentences will be provided to the patient. Each single word may be read aloud up to two times. The partner must then select the read word out of a list of twelve possible words. Each sentence may be read aloud up to two times. The partner must transcribe each sentence on a standardized form. A survey will be provided to evaluate the mask on, communicator on period.
13
Total36

Baseline characteristics

CharacteristicF2S CommunicatorTotalNon-functioning Communicator
Age, Continuous55.4 years
STANDARD_DEVIATION 13.3
57.03 years
STANDARD_DEVIATION 14.7
59.9 years
STANDARD_DEVIATION 17.1
Race (NIH/OMB)
American Indian or Alaska Native
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Asian
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Black or African American
13 Participants17 Participants4 Participants
Race (NIH/OMB)
More than one race
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Unknown or Not Reported
0 Participants0 Participants0 Participants
Race (NIH/OMB)
White
10 Participants19 Participants9 Participants
Region of Enrollment
United States
23 participants36 participants13 participants
Sex: Female, Male
Female
13 Participants19 Participants6 Participants
Sex: Female, Male
Male
10 Participants17 Participants7 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
0 / 230 / 13
other
Total, other adverse events
0 / 230 / 13
serious
Total, serious adverse events
0 / 230 / 13

Outcome results

Primary

Accuracy of Sentence Selection (Proportion of Right Sentences From Total)

Data will be collected using audio recording - accuracy of sentence selection (spoken by patient -\> transcribed by partner). The communicator will be attached to the BPAP/CPAP mask. A list of 5-word through 15-word sentences will be provided to the patient. Each sentence may be read aloud by patient up to two times. The partner must transcribe each sentence on a standardized form.

Time frame: Mask on-communicator on-20 minutes

ArmMeasureValue (MEAN)Dispersion
F2S CommunicatorAccuracy of Sentence Selection (Proportion of Right Sentences From Total)0.76 proportion of sentence intelligibilityStandard Deviation 0.22
Non-functioning CommunicatorAccuracy of Sentence Selection (Proportion of Right Sentences From Total)0.33 proportion of sentence intelligibilityStandard Deviation 0.25
Primary

Accuracy of Single Word Selection (Proportion of Right Words From Total)

Data will be collected using audio recording - accuracy of single word selection (spoken by patient -\> selected by partner). The communicator will be attached to the BPAP/CPAP mask. A list of single words will be provided to the patient. Each single word may be read aloud by patient up to two times. The partner must then select the read word out of a list of twelve possible words.

Time frame: Mask on-communicator on-20 minutes

ArmMeasureValue (MEAN)Dispersion
F2S CommunicatorAccuracy of Single Word Selection (Proportion of Right Words From Total)0.61 proportion of right wordsStandard Deviation 0.13
Non-functioning CommunicatorAccuracy of Single Word Selection (Proportion of Right Words From Total)0.35 proportion of right wordsStandard Deviation 0.17
Secondary

Number of Subjects That Found That the Device Significantly Improved Noninvasive Ventilation (NIV) Comfort

Number of subjects that found that the device significantly improved noninvasive ventilation (NIV) comfort was calculated and reported. Assessment of noninvasive ventilation (NIV) comfort was conducted using Likert Scale Score on clarity of communication on a symmetric seven-level agree-disagree scale.

Time frame: Mask on-communicator on-20 minutes

ArmMeasureValue (COUNT_OF_PARTICIPANTS)
F2S CommunicatorNumber of Subjects That Found That the Device Significantly Improved Noninvasive Ventilation (NIV) Comfort11 Participants
Non-functioning CommunicatorNumber of Subjects That Found That the Device Significantly Improved Noninvasive Ventilation (NIV) Comfort2 Participants
Secondary

Speech Transmission Index (STI)

STI is a numeric representation measure of communication channel characteristics whose value varies from 0 = bad to 1 = excellent.On this scale, an STI of at least 0.5 is desirable for most applications.

Time frame: Mask on with communicator on (20 min)

Population: A validated conversion for word/sentence accuracy and STI was not predetermined and the intent was to record at both the mask and the speaker. However, the conversion was not able to be determined and recording at the mask level was limited by the device. Thus, there is no effective comparator to calculate STI and this information is unavailable.

Source: ClinicalTrials.gov · Data processed: Feb 25, 2026