Skip to content

Capnogram and Fluid Responsiveness

Performance of CO2 Changes to Predict Fluid Responsiveness in Spontaneously Breathing Volunteers

Status
Withdrawn
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03788707
Enrollment
0
Registered
2018-12-28
Start date
2019-05-01
Completion date
2021-12-01
Last updated
2021-07-28

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Healthy, Blood Pressure

Brief summary

Predicting fluid responsiveness in critically ill patients is of paramount importance. It can help define an adequate fluid balance. Overzealous fluid administration is poorly tolerated and has been associated with poor outcomes but so has insufficient administration. Currently available predictors of fluid responsiveness rely on invasive monitors and require patients to be on mechanical ventilation. It is thus important to develop non invasive novel methods to assess fluid responsiveness to provide an accurate management for a favorable outcome. We propose a readily available non-invasive method that relies on improvement of the ventilation perfusion mismatch as recorded by end tidal CO2. Ventilation of physiologic dead space is part of a spectrum of mismatch between ventilation and perfusion of the lungs. The extent of pulmonary dead space varies depending on factors affecting pulmonary perfusion (e.g. pulmonary capillary hydrostatic pressure) and alveolar pressure (e.g. positive pressure ventilation). Compromised pulmonary capillary perfusion can lead to ventilation-perfusion mismatch in a patient with clear conductive airway and adequate alveolar oxygen pressure. Alveolar dead space results in decreased CO2 exchange that translates into lower levels of expired CO2. Stroke volume of the right ventricle is a major determinant of the pulmonary capillary perfusion. Right ventricular cardiac output can be increased by passive lower limb elevation maneuver, which ultimately results in improvement of the ventilation to perfusion ratio. This effect leads to a higher participation of perfused (and ventilated) alveolar units in gas exchange and narrowing of the gradient between arterial and expired CO2 concentration. Performing a passive leg raising (PLR) maneuver leads to stroke volume enhancement in both healthy patients and in those experiencing hemodynamic instability. Responsiveness to PLR can be assessed by different methods including echocardiography and pulse pressure variation. Left ventricular cardiac output (LVCO) can be easily measured by transthoracic echo and be used as a surrogate of right ventricular preload changes. LVCO can thus be used to assess the fluid responsiveness of PLR and the effects of on end tidal CO2 that ensue. We propose this study to test the hypothesis that expired CO2 is a reliable predictor of fluid responsiveness after performance of the PLR maneuver, based on the assumption that increasing right ventricular output causes a reduction of the ventilation to perfusion ratio, leading to increased levels of expired CO2. T

Interventions

After 30 seconds of lying flat, volunteers will have passive leg raising to 45 degrees. Expired CO2 will be measured via a face mask before and after leg raising.

Sponsors

Augusta University
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Intervention model description

Volunteers will lay flat with a face mask breathing room air while expired CO2 is measured. After 30 seconds, legs will be passively raised for 3 minutes. Changes in expired CO2 before and after leg raising will be compared.

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Age older than 18 years

Exclusion criteria

* Cardiovascular and respiratory disease reported by the participant

Design outcomes

Primary

MeasureTime frameDescription
Expired CO210 minutesArea under the curve of a capnogram tracing will be measured in milimiters

Secondary

MeasureTime frameDescription
Mean arterial pressure10 minutesMean arterial pressure in mmHg measured by non invasive oscillometer
Heart rate10 minutesbeats per minute measured by non invasive plethysmography

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026