Acute Respiratory Failure
Conditions
Keywords
non invasive ventilation, patient ventilator synchrony, acute respiratory failure, closed loop ventilation
Brief summary
This cross-over study will compare the asynchrony index between standard manual ventilator settings, optimized manual ventilator settings, and automated ventilator setting in intensive care patients ventilated in non-invasive ventilation with a high asynchrony index. The hypothesis is that both manual optimized ventilator settings and automated ventilator settings are associated with a lower patient-ventilator asynchrony index as compared to manual standard ventilator settings. A randomized cross-over design method will be used. Patient requiring NIV with an asynchrony index over 35% will be included. An esophageal catheter with a balloon will be inserted to monitor esophageal pressure. Patients will be ventilated during 3 periods of 30 min, with 10 minutes of washout in between. Recordings of airway pressure, airway flow, and esophageal pressure will be analyzed by two investigators blinded of the trigger settings. The primary outcome will be the asynchrony index. The secondary outcome will be the ineffective inspiratory effort index, autotrigering index, double triggering index, inspiratory trigger delay, cycling delay, total time spent in asynchrony, patient comfort, and blood gas results.
Detailed description
Non-invasive ventilation (NIV) is used in 35% of patient admitted in intensive care unit (ICU) with a failure rate of 10 to 70% depending on the indication and clinician experience. Patient-ventilator asynchrony is a frequent cause of NIV failure. Therefore, optimizing patient-ventilator synchronization is important for its comfort, tolerance, and efficacy. An optimal patient-ventilation is achieved when the mechanical breath provided by the ventilator match the patient inspiratory effort. The ratio between the number of asynchronies divided by the number of patient inspiratory effort define the asynchrony index (AI). AI over 10% is considered as severe and occurs in 30 to 43% of patients ventilated in NIV. Patient ventilator asynchronies occurs because ventilator settings of inspiratory and expiratory triggers remain constant in patient with variable respiratory drive, and unintentionnals leaks that are difficult to control in NIV. Thus using an automatic adjustment of inspiratory and expiratory triggers setting according to patient effort and unintentional leaks may decrease the number of patient-ventilator asynchronies. This cross-over study will compare the asynchrony index between standard manual ventilator settings, optimized manual ventilator settings, and automated ventilator setting in intensive care patients ventilated in non-invasive ventilation with a high asynchrony index. The hypothesis is that both manual optimized ventilator settings and automated ventilator settings are associated with a lower patient-ventilator asynchrony index as compared to manual standard ventilator settings. A randomized cross-over design method will be used. Patient requiring NIV with an asynchrony index over 30% will be included. An esophageal catheter with a balloon will be inserted to monitor esophageal pressure. Patients will be ventilated during 3 periods of 30 min, with 10 minutes of washout in between. Recordings of airway pressure, airway flow, and esophageal pressure will be analyzed by two investigators blinded of the trigger settings. The primary outcome will be the asynchrony index. The secondary outcome will be the ineffective inspiratory effort index, autotrigering index, double triggering index, inspiratory trigger delay, cycling delay, total time spent in asynchrony, patient comfort, and blood gas results. The sample size was calculated from the total asynchrony index (primary outcome). Patients with an asynchrony index over 30% in using manual standard ventilator settings will be included. Considering an asynchrony index of 30 ± 15 % in manual standard ventilator settings with a clinically significant objective to reduce the asynchrony index to 15% in manual optimized ventilator settings and automated ventilator settings, a sample size of 30 patients is required with a risk at 0.05 and a power at 80%. Therefore, 35 patients are planned.
Interventions
Inspiratory trigger and Expiratory trigger settings optimized by investigator
Inspiratory trigger and Expiratory trigger settings automatized
Sponsors
Study design
Eligibility
Inclusion criteria
* Patient aged over 18 years old * Covered by social insurance * Consent for study signed by patient or next-of-kin * NIV session indicated for at least 2 hours * Asynchrony index ≥ 30% with standard manual settings
Exclusion criteria
* Patient requiring continuous NIV * Contra-indication to esophageal catheter insertion: gastric ulcer, esophageal varices, pharyngeal or laryngeal tumor. * Patient with withholding decision about intubation * Moribund patient * Patient included in another interventional study in the last 30 days * Patient that does not speak French * Pregnant women
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| Asynchrony index | Continuous measurement over 30min | Ratio between the total number of asynchronies divided by the number of patient inspiratory effort |
Secondary
| Measure | Time frame | Description |
|---|---|---|
| Autotrigering index | Continuous measurement over 30min | Ratio between the total number of autotriggered breath divided by the number of patient inspiratory effort |
| Double triggering index | Continuous measurement over 30min | Ratio between the total number of double triggered breath divided by the number of patient inspiratory effort |
| Inspiratory trigger delay | Continuous measurement over 30min | Time between the beginning of patient effort assessed on oesophageal pressure and beginning of mechanical breath. |
| Cycling delay | Continuous measurement over 30min | Time between the end of patient effort assessed on oesophageal pressure and the end of mechanical breath. |
| Lineffective inspiratory effort index | Continuous measurement over 30min | Ratio between the total number of ineffective inspiratory effort divided by the number of patient inspiratory effort |
| Patient comfort | 1 day (Single measurement) | Visual analog scale of Likert type measuring patient comfort going from 0 (very uncomfortable) to 10 (very comfortable) |
| Blood PaO2 results | After each period at 30 min, 1 h and 1 h 30 min | PaO2 |
| Blood PaCO2 results | After each period at 30 min, 1 h and 1 h 30 min | PaCO2 |
| Blood pH results | After each period at 30 min, 1 h and 1 h 30 min | pH |
| Total time spent in asynchrony | Continuous measurement over 30min | Ratio of total time of ineffective inspiratory effort, inspiratory trigger delay, and cycling delay on total time of recording. |
Countries
France