Skip to content

Optic Nerve Sheath Diameter Difference

Effect of Different Posture on Optic Nerve Sheath Diameter During Thoracic Epidural Catheterization

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03785314
Enrollment
44
Registered
2018-12-24
Start date
2019-01-02
Completion date
2019-12-30
Last updated
2020-02-24

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Optic Neve Sheath Diameter

Keywords

Optic Nerve Sheath Diameter Different Position

Brief summary

Intracranial pressure is measured indirectly using optic nerve sheath diameter with ultrasound. It is reported that epidural pressure varies according to different posture ( lateral decubitus vs. sitting position). This study is designed to measure the optic nerve sheath diameter in lateral decubitus and sitting position, respectively.

Detailed description

According to previous study, injection of different volume of local anesthetics (1.0 ml/kg vs. 1.5 ml/kg) during caudal anesthesia, high volume of local anesthetics resulted in significant increase of intracranial pressure (ICP). Increase of ICP can reduce regional cerebral flow and oxygen saturation causing the safety of patients. In addition, increase of ICP can result in headache, syncope, and transient loss of visual acuity. Although it is very invasive method, ICP can be measured directly at the brain parenchyme. Among methods to measure the ICP indirectly, measurement of optic nerve sheath diameter using ultrasound is known to reflect the degree of ICP. It is reported that optic nerve sheath diameter increases when higher volume of medication is injected during epidural anesthesia. Previous reports showed that epidural pressure varies according to different posture. When epidural pressure was measured in patients of spinal stenosis, lumbar flexion showed lower epidural pressure than epidural pressure of lumbar extension. In addition, when epidural pressure was measured in the sitting position, it showed lower pressure than pressure of lateral decubitus.

Interventions

thoracic epidural catheterization with different posture

Sponsors

Keimyung University Dongsan Medical Center
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
DOUBLE (Subject, Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Age
20 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

* lung cancer * liver cancer * stomach cancer * pancreas cancer

Exclusion criteria

* coagulopathy * infection * previous spine fusion at thoracic level * previous brain surgery

Design outcomes

Primary

MeasureTime frameDescription
optic nerve sheath diameter change among 4 time periodBaseline, 10 minutes, 20 minutes, 40 minutes after the completion of the interventionoptic nerve sheath diameter change among 4 time period using ultrasound

Countries

South Korea

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026