Performance Evaluation of a Novel Non-invasive Glucometer, Calibrated Against Validated Interstitial Glucose References

Performance Evaluation of a Novel Non-invasive Glucometer, Calibrated Against Validated Interstitial Glucose References

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03782649
Enrollment
12
Registered
2018-12-20
Start date
2018-11-29
Completion date
2019-06-19
Last updated
2019-12-12

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Diabetes Mellitus

Keywords

Non-invasive glucose monitoring, Raman spectroscopy

Brief summary

This clinical study has been launched to collect spectral Raman data on the Investigational Medical Device (IMD) compared with reference methods in terms of interstitial fluid samples and capillary and venous references.

Detailed description

Subjects will visit the clinic for a baseline visit and two in-clinic visits. On in-clinic days, subjects will attend the clinic in a fasting state. They will have inserted a Dexcom and Freestyle Libre and a microdialysis catheter. At time = 0, subjects will be administered a glucose rich drink and every 6. minut measurements will be performed. These include a measurement on the IMD, microdialysate, FreeStyle Libre and Dexcom readings. Every 18. minut a venous blood sample will be included and every 36. minut a capillary blood sample will be collected. This continues until time = 180 minutes.

Interventions

DEVICEWorking Model 3.4NR

Investigational Medical Device collecting spectral Raman data from tissue

Sponsors

RSP Systems A/S
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DEVICE_FEASIBILITY
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 70 Years
Healthy volunteers
No

Inclusion criteria

* Male and female subjects 18-70 years old * Patients diagnosed with type 1 or type 2 diabetes (T1D or T2D) (insulin requiring T2D patients) * Diabetes management strategy: lifestyle regimen + insulin ± oral hypoglycemic agents * Skin phototype 1-4

Exclusion criteria

* For female participants: Pregnancy or subject is attempting to conceive or not willing and able to practice birth control during the study duration * \> 10 cigarettes pr. day * Participants not able to understand and read Swedish * In investigator's opinion, participant is not able to follow instructions as specified in the protocol * Participants not able to hold hand/arm steadily (including tremors and Parkinson's Disease) * Diagnosed with reduced circulation * Extensive skin changes, tattoos or diseases on probe application site * Rejection by screening optical measurements * Known allergy to medical grade alcohol * Known allergy to adhesives * Systemic or topical administration of glucocorticoids for the past 7 days * Participants undergoing dialysis treatment * Anti-coagulation or anti-platelet therapy * Use of beta-blockers * Medical conditions causing bleeding tendency * Medical history or any condition that may, in the opinion of the investigator, compromise the subject's ability to participate * Concomitant medical condition which could present a risk to the safety or welfare of the subject or study staff. Such conditions include but are not limited to HIV and Hepatitis B or C. * Participants currently enrolled in another study

Design outcomes

Primary

MeasureTime frameDescription
Generation and validation of prediction models - MARDOne yearTwo in-clinic visits each of a duration of 5-6 hours are scheduled for each subject. Subjects will enter clinic in fasting state and will receive an oral glucose bolus. Glucose excursion is followed with frequent capillary and venous blood samples along with FGM and CGM readings and microdialysis. In parallel, optical glucose data from the investigational medical device will be collected. Optical glucose readings will be masked to the subjects. Collected data will be used to generate individual calibration models capable of predicting tissue glucose. Models will be validated on independent data sets using Mean Absolute Relative Difference (MARD) endpoint measure.
Generation and validation of prediction models - ISUPOne yearTwo in-clinic visits each of a duration of 5-6 hours are scheduled for each subject. Subjects will enter clinic in fasting state and will receive an oral glucose bolus. Glucose excursion is followed with frequent capillary and venous blood samples along with FGM and CGM readings and microdialysis. In parallel, optical glucose data from the investigational medical device will be collected. Optical glucose readings will be masked to the subjects. Collected data will be used to generate individual calibration models capable of predicting tissue glucose. Models will be validated on independent data sets using Inter Subject Unified Performance (ISUP) measure.
Generation and validation of prediction models - Consensus Error GridOne yearTwo in-clinic visits each of a duration of 5-6 hours are scheduled for each subject. Subjects will enter clinic in fasting state and will receive an oral glucose bolus. Glucose excursion is followed with frequent capillary and venous blood samples along with FGM and CGM readings and microdialysis. In parallel, optical glucose data from the investigational medical device will be collected. Optical glucose readings will be masked to the subjects. Collected data will be used to generate individual calibration models capable of predicting tissue glucose. Models will be validated on independent data sets using Consensus Error Grid Analysis

Secondary

MeasureTime frameDescription
Evaluation of dynamics between arterial and venous glucose profiles in relation to interstitial glucose levelsOne yearTwo in-clinic visits each of a duration of 5-6 hours are scheduled for each subject. Subjects will enter clinic in fasting state and will receive an oral glucose bolus. Glucose excursion is followed with frequent capillary and venous blood samples along with FGM and CGM readings and microdialysis. In parallel, optical glucose data from the investigational medical device will be collected. Optical glucose readings will be masked to the subjects. A modeling-based evaluation of the dynamics between blood glucose and tissue glucose will be conducted and serve as a secondary endpoint of the study.
Safety evaluation: paucity of adverse eventsOne yearSafety will be evaluated in a descriptive manner by the paucity of adverse events

Countries

Sweden

Outcome results

None listed