M5 vs. M6 Comparison Study With a Sub Study Into the Dielectric Constant of Aspirated Cyst Fluid

Comparison of M5 and M6 Versions of the MARIA Imaging System on Patients Attending Symptomatic Breast Clinic in Cheltenham, United Kingdom (UK), Including a Sub-study to Research the Dielectric Constant of Aspirated Cyst Fluid

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03771833
Enrollment
22
Registered
2018-12-11
Start date
2019-02-19
Completion date
2020-01-23
Last updated
2020-02-20

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Breast Cancer Female, Breast Cyst

Keywords

breast, cancer, breast cancer, imaging

Brief summary

The MARIA breast imaging system is a Conformité Européenne (CE)-marked radio-frequency (RF) medical imaging device. The system employs an electromagnetic imaging technique that exploits the dielectric contrast between normal and cancerous tissues. The performance and imaging characteristic differences between the M5 and M6 versions of MARIA are not yet well demonstrated in the clinical environment, particularly with regards to cysts. The evaluation of some aspects of this potentially important new technology will occur in this comparative technical study. Further, the dielectric constant of cyst fluid is currently not well understood and obtaining readings from aspirated cyst fluid in applicable patients will be attempted.

Interventions

The MARIA breast imaging system comprises of a scanning unit, housed under a patient bed. The scanning unit houses a hemispherical array, into which varying sizes of insert are fitted to ensure a close fit to the breast. The patient lies prone on the bed with their breast pendulous through an aperture in the bed and the scanning unit is risen to meet the breast. The fit is non-compressing and the scanner does not use ionising radiation.

Sponsors

Micrima, Ltd.
Lead SponsorINDUSTRY

Study design

Allocation
NON_RANDOMIZED
Intervention model
PARALLEL
Primary purpose
OTHER
Masking
NONE

Eligibility

Sex/Gender
FEMALE
Age
18 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

* attending a symptomatic breast care clinic at the study site * have a palpable lump in the breast * female sex * 18 years or older * able to provide informed consent * not in any identified vulnerable group

Exclusion criteria

* unable to mount MARIA patient bed using provided 2-step * unable to lie in the prone position for a period of up to 15 minutes * patient who have undergone biopsy less than 5 days before the MARIA scan * patient with implanted electronics * patient with breast implants * patients with nipple piercings (unless they are removed prior to the MARIA scan) * breast size too small or too large to be suitable for both arrays Further: * participants with a large cyst or cysts that require draining at their clinical appointment will not be eligible for Arm 1, as the procedure to drain their cyst will change the appearance of the cyst from the imaging that they have done that day to the MARIA image obtained around 10 days later * Arm 1 and 2 are mutually exclusive

Design outcomes

Primary

MeasureTime frameDescription
Establish the presence or absence of a difference in the MARIA(R) outputs obtained with M5 and M6 when the participants is not moved between scans and when they are moved between scansUp to 12 weeksThis will be established from Arm 1 and Arm 2 by scanning the participant between both versions of the MARIA system. As has been investigated in-house with healthy volunteers, the patient will take part in a series of scans that will involve them remaining stationary between scans, and moving between scans. The differences between these images will be analysed, using the known palpable lesion in the breast as a landmark.
Establish the presence or absence of a difference between MARIA(R) outputs on the same device when the participant is stationary between scans and when they are moved between scansUp to 12 weeksThis will be established from Arm 1 and Arm 2 by scanning the participant on each separate version of the MARIA system. As has been investigated in-house with healthy volunteers, the patient will take part in a series of scans that will involve them remaining stationary between scans, and moving between scans. The differences between these images will be analysed, using the known palpable lesion in the breast as a landmark.
Measure the dielectric constant of aspirated cyst fluid and any variance between cyst typeUp to 12 weeksThis will be established from Arm 2b by recording the dielectric constant of the aspirated cyst fluid as soon as possible after aspiration using a dielectric probe. No cysts will be aspirated exclusively for this procedure and fluid will be disposed of as per usual site practice once the recording has taken place. Each cyst fluid sample will have its dielectric constant recorded three times and recorded in the provided software before disposal.

Secondary

MeasureTime frameDescription
Assess the diagnostic accuracy of both the M5 and M6 versions of the MARIA system in identifying lesions of the breast, including benign lesions such as cystsUp to 12 weeksThis will be established from Arm 1 and 2 by using a combination of reader results from clinician reads performed by the site team with all available clinical information and blind reads performed in house which will utilise no clinical information.
Understand participant acceptability of the MARIA scan and obtain feedback on patient experience: questionnaireUp to 12 weeksThis will be established from Arm 1 and 2 by asking the participant to complete a questionnaire of their experience after their participation in either of the two main study arms. The questionnaire comprises of 8 questions and a free-text box for any additional comments. The first two questions ask a participant to pick one of 5 options, from very easy to very difficult or very comfortable to very uncomfortable. The next even questions are Yes or No questions, with options for the participant to answer these as Not sure or Not applicable as appropriate. The questionnaire then ends with a free-text box for feedback.

Countries

United Kingdom

Outcome results

None listed