Skip to content

The Efficacy of MDI Treatment With an Optimization Algorithm Adjusting Basal-Bolus Parameters in Children and Adolescents With Type 1 Diabetes at a Diabetes Camp

An Open-Label, Randomized, Two-Way, Parallel Study to Compare the Efficacy of MDI Treatment With Physician Adjusted and Optimization Algorithm Adjusted Basal-Bolus Parameters in Children and Adolescents With Type 1 Diabetes at a Diabetes Camp

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03764280
Enrollment
21
Registered
2018-12-05
Start date
2018-07-02
Completion date
2018-08-10
Last updated
2019-08-15

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Diabete Mellitus, Diabetes Mellitus, Type 1

Keywords

Multiple Daily Injections, type 1 diabetes, pediatrics, optimization algorithm

Brief summary

Our lab at McGill University has developed an optimization algorithm for T1D MDI patients that estimates optimal basal-bolus parameters (basal injections and insulin-to-carbohydrate ratios) using glucose sensor data and insulin dosing data over several days. The algorithm examines daily glucose, insulin, and meal data to make changes in patients' basal injections and ICRs. The investigators hope that this algorithm will be able to optimize the patients' individual basal injections and ICRs in order to improve glycemic control.

Detailed description

The objective of this project is to compare our basal-bolus optimization algorithm with physician adjusted basal-bolus parameters using a randomized parallel clinical trial in children and adolescents at a Camp Carowanis. The investigators hypothesize that using this optimization algorithm will be non-inferior to the physician-adjusted basal-bolus parameters regarding time spent in target glucose range (3.9 mmol/L - 10mmol/L). Between 40 and 68 children and adolescent type 1 diabetes patients undergoing MDI treatment at Camp Carowanis will randomly undergo one of two interventions: 1. MDI with Physician Adjusted Basal-Bolus Parameters: Participants will be wearing the Freestyle Libre glucose sensor (Abbott Diabetes Care). Participants will undergo their conventional multiple daily injection (MDI) therapy. At breakfast, the research team will download the sensor data. Camp physicians will review each participant's sensor and insulin data and make changes to their parameters based on their clinical judgement, as they would for all campers, regardless of study participation. These new parameters will be entered into the patient's camp file. 2. MDI with Basal-Bolus Optimization Algorithm Adjusted Basal-Bolus Parameters: Participants will be wearing the Freestyle Libre glucose sensor (Abbott Diabetes Care). At breakfast, the data from the glucose sensor and injection information will be entered into a computer and the optimization algorithm will be run. Camp physicians will review the algorithm's recommendations before they are entered into the patient's camp file.

Interventions

OTHERMultiple Daily Injections: Slow acting insulin and Rapid acting insulin

Multiple daily injections (MDI) therapy involves four or more daily insulin injections. Once or twice daily, a long acting insulin is injected as a basal dose. These long acting insulins are designed to dissipate slowly and evenly into the bloodstream for 24 to 36 hours following injection. This basal injection aims to mimic the physiological healthy basal insulin released from a healthy pancreas all day. Furthermore, multiple insulin bolus doses are injected at every meal each day using rapid or short acting insulin. These injections are administered before meals and are calculated using patients' ICRs and meal carbohydrate quantities.

Sponsors

McGill University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
SINGLE (Subject)

Intervention model description

This is an open-label, randomized, two-way, parallel study to compare the glucose control between physician adjusted basal-bolus parameters and our computer basal-bolus optimizing algorithm. Children and adolescent type 1 diabetes patients at Camp Carowanis, a camp for diabetes, will be enrolled in the study, where they will randomly undergo one of two interventions: 1. MDI with Physician Adjusted Basal-Bolus Parameters 2. MDI with Basal-Bolus Optimization Algorithm Adjusted Basal-Bolus Parameters (OA)

Eligibility

Sex/Gender
ALL
Age
8 Years to 21 Years
Healthy volunteers
No

Inclusion criteria

1. Males and females between 8 and 18 years old. 2. Clinical diagnosis of type 1 diabetes for at least 12 months. The diagnosis of type 1 diabetes is based on the investigator's judgment; C peptide level and antibody determinations are not needed. 3. Undergoing multiple daily injection therapy. 4. HbA1c ≤ 11%.

Exclusion criteria

1. Serious medical illness likely to interfere with study participation or with the ability to complete the trial by the judgment of the investigator. 2. Failure to comply with the study protocol or with team's recommendations. 3. Injection of isophane insulin (NPH) or any intermediate-acting insulin 4. More than one injection of slow-acting insulin per day.

Design outcomes

Primary

MeasureTime frame
Percentage of time of sensor glucose levels spent in target range (defined to be between 3.9 mmol/L and 10.0 mmol/L).the last 7 days of the study.

Secondary

MeasureTime frameDescription
Percentage of overnight time (23:00-7:00) of sensor glucose levelslast 7 days of the studya. between 3.9 and 7.8 mmol/L; b. between 3.9 and 10 mmol/L; c. below 3.9 mmol/L; d. below 3.3 mmol/L; e. below 2.8 mmol/L; f. above 7.8 mmol/L; g. above 10 mmol/L; h. above 13.9 mmol/L; i. above 16.7 mmol/L.
Percentage of daytime (7:00-23:00) of sensor glucose levelslast 7 days of the studya. between 3.9 and 7.8 mmol/L; b. between 3.9 and 10 mmol/L; c. below 3.9 mmol/L; d. below 3.3 mmol/L; e. below 2.8 mmol/L; f. above 7.8 mmol/L; g. above 10 mmol/L; h. above 13.9 mmol/L; i. above 16.7 mmol/L.
Standard deviation of glucose levels as a measure of glucose variabilitylast 7 days of the study
Percentage of time of sensor glucose levels spent:last 7 days of the studya. between 3.9 and 7.8 mmol/L; b. between 3.9 and 10 mmol/L; c. below 3.9 mmol/L; d. below 3.3 mmol/L; e. below 2.8 mmol/L; f. above 7.8 mmol/L; g. above 10 mmol/L; h. above 13.9 mmol/L; i. above 16.7 mmol/L.
Mean sensor glucose level duringlast 7 daysa. the overall study period; b. the daytime period; c. overnight period.
Number of participants experiencing hypoglycemia requiring oral treatment duringlast 7 daysa. the overall study period; b. the daytime period; c. overnight period.
Total insulin delivery.last 7 days

Countries

Canada

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026