Non-Invasive Monitoring of Partial Pressure of Carbon Dioxide in Mechanically Ventilated Preterm Infants

Non-Invasive Monitoring of Partial Pressure of Carbon Dioxide in Mechanically Ventilated Preterm Infants

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03758313
Enrollment
27
Registered
2018-11-29
Start date
2018-11-01
Completion date
2020-09-30
Last updated
2021-08-17

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Preterm Infant

Brief summary

In mechanically ventilated preterm infants, the ability to monitor carbon dioxide partial pressure (pCO2) values is indispensable. The gold standard for pCO2 measurement is from an arterial blood sample (paCO2). This has two drawbacks: firstly, it requires an arterial line and, secondly, it does not provide the clinicians with a continuous measurement. At present, two alternative pCO2 monitoring systems are available in the field of neonatal intensive care medicine: end-tidal CO2 (etCO2) capnography and transcutaneous CO2 (tcCO2) measurements. Both methods have disadvantages including potential technical errors as well as pathologies that may reduce reliability as a surrogate for blood gas analysis (BGA). In particular, conventional side-stream etCO2 capnography underestimates pCO2 in presence of a tube leakage, which is a common occurrence in ventilated preterm infants where only tubes without cuff are used. Distal etCO2 (detCO2) by means of a double lumen endo-tracheal tube may solve the problem of unreliable etCO2 values in the presence of tube leakage. The aim of this study is to compare the agreement, precision and repeatability of the distal etCO2-measurement technique described by Kugelman et al. with respect to paCO2 and tcCO2 in mechanically ventilated preterm infants. Since ventilation strategies and pCO2 limits may vary among different centers, this study helps to determine which non-invasive CO2 monitoring system (detCO2 or tcO2) is more suitable in terms of applicability and reliability in preterm infants at our neonatal intensive care units.

Detailed description

Background: In mechanically ventilated preterm infants, the ability to monitor carbon dioxide partial pressure (pCO2) values is indispensable. The gold standard for pCO2 measurement is from an arterial blood sample (paCO2). This has two drawbacks: firstly, it requires an arterial line and, secondly, it does not provide the clinicians with a continuous measurement. At present, two alternative pCO2 monitoring systems are available in the field of neonatal intensive care medicine: end-tidal CO2 (etCO2) capnography and transcutaneous CO2 (tcCO2) measurements. Both methods have disadvantages including potential technical errors as well as pathologies that may reduce reliability as a surrogate for blood gas analysis (BGA). In particular, conventional side-stream etCO2 capnography underestimates pCO2 in presence of a tube leakage, which is a common occurrence in ventilated preterm infants where only tubes without cuff are used. Distal etCO2 (detCO2) by means of a double lumen endo-tracheal tube may solve the problem of unreliable etCO2 values in the presence of tube leakage. Several studies compared etCO2 and tcCO2 to paCO2, simultaneously. A comparison study of etCO2 and tcCO2 in a cohort of critically ill children did not reveal significant differences in the absence of severe pulmonary parenchymal disease. Tobias et al compared etCO2 and tcCO2 in a cohort of pediatric intensive care patients with respiratory failure and found tcCO2 measurements to be more accurate. In a cohort of ventilated newborns, tcCO2 monitoring was generally more precise than etCO2 during neonatal transport to monitor ventilation. In a more recent study restricted to a cohort of postsurgical neonates without lung disease, etCO2 underestimated paCO2 more than tcCO2 but provided greater precision over paCO2, however it was less accurate at smaller tidal volumes. These studies have in common that the adapter of the pCO2 analyzer was attached in-line and proximal to the endotracheal tube. Aim of the study: The aim of this study is to compare the agreement, precision and repeatability of the distal etCO2-measurement technique described by Kugelman et al. with respect to paCO2 and tcCO2 in mechanically ventilated preterm infants. Since ventilation strategies and pCO2 limits may vary among different centers, this study helps to determine which non-invasive CO2 monitoring system (detCO2 or tcO2) is more suitable in terms of applicability and reliability in preterm infants at our neonatal intensive care units.

Interventions

OTHERCO2 measurements

Distal etCO2, tcCO2 and paCO2 values will be recorded simultaneously in ventilated preterm infants. We will measure etCO2 in a distal position using a double lumen tube connected to an external side-stream capnometer.

Sponsors

Tobias Werther
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

* Preterm infants with a current body weight between 1000 g and 3000 g who require intubation. * Signed informed consent from parents or legal guardians. * Expected to provide at least three measurements of paCO2 and detCO2.

Exclusion criteria

* Infants with known congenital anomalies of the heart and/or lung. * Need for high frequency oscillation. * Parents or legal guardians deny informed consent.

Design outcomes

Primary

MeasureTime frameDescription
Carbon Dioxide in Mechanically Ventilated Preterm Infants48 hourspartial pressure of carbon dioxide

Countries

Austria

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 14, 2026