Skip to content

The Critical Threshold of Pulse Oximetry Plethysmographic Waveform Parameters in High Quality CPR

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03754946
Enrollment
1000
Registered
2018-11-27
Start date
2015-09-01
Completion date
2018-12-31
Last updated
2018-11-27

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cardiopulmonary Resuscitation

Keywords

cardiopulmonary resuscitation, pulse oximetry plethysmographic waveform, quality monitor, partial pressure of end-tidal carbon dioxide

Brief summary

The purpose of this study is to analyze the relationship of the area under the curve (AUC) and/or the amplitude (Amp) of pulse oximetry plethysmographic waveform (POP) with partial pressure of end-tidal carbon dioxide (PETCO2) which could be used to reflect its quality in cardiopulmonary resuscitation (CPR), and then to determine the critical threshold of POP parameters in high quality CPR.

Interventions

None listed

Sponsors

Peking Union Medical College Hospital
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 75 Years
Healthy volunteers
No

Inclusion criteria

* Cardiac arrested * The time from cardiac arrest to receiving basic life support is less than 10 minutes * Get advanced life support (endotracheal intubation and PETCO2 monitoring)

Exclusion criteria

* Defuse CPR * chronic obstructive pulmonary disease (COPD) with type II respiratory failure * Terminal malignant tumors or terminal stage of other diseases * Rib fracture * Cardiac arrest caused by hemorrhagic shock pulmonary embolism and cardiac tamponade * Sever anemia(HGB\<7g/dl) * Untreated tension pneumothorax * Tinea unguium, dyeing Fingernails and other factors affect the monitor of Pulse Oximetry Plethysmographic Waveform such vasculitis and Raynaud's phenomenon

Design outcomes

Primary

MeasureTime frameDescription
the cut-off value of POP parameters in High Quality CPRone yearDescribe the the cut-off value of POP parameters in High Quality CPR. Receiver operating curve analysis was performed to evaluate the accuracy in predicting return of spontaneous circulation (ROSC).
Compare different predictorsone yearArea under curve (AUC) between potential predictors was compared by using a nonparametric test, and the optimal cutoff point was determined by estimating the Youden's index.

Countries

China

Contacts

Primary ContactXuezhong Yu, MD
yxzpumch@126.com+86 010 69159142

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026