Skip to content

Transfer Accuracy of Indirectly Bonded Orthodontic Braces With Different Transfer Trays

Transfer Accuracy of Indirectly Bonded Orthodontic Attachments With Vacuum Formed and Silicone Transfer Trays

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03754283
Enrollment
16
Registered
2018-11-27
Start date
2017-06-01
Completion date
2017-09-01
Last updated
2018-11-27

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Malocclusion

Keywords

Indirect bonding, Accuracy

Brief summary

The aim of this study is to comparatively investigate the performances of two different and widely used transfer trays during indirect bonding of the orthodontic braces.

Detailed description

The aim of the study is to compare the accuracy of orthodontic bracket and tube transfer between double layer silicone and double layer vacuum formed trays. The sample included 368 attachments bonded in 16 patients. Each patient received one silicone and one vacuum formed tray which were randomly allocated to provide 8 trays of each type for the upper and lower arches. 3D scan data and local best-fit alignments were used to calculate the translational and rotational movements of the orthodontic attachments. Chi-square and Mann-Whitney U tests were used to compare transfer accuracy and success between the groups.

Interventions

Indirect bonding is the technique where orthodontic appliances are first placed on a model of the patient and then transferred to the patient using some kinf of trays

Sponsors

Yuzuncu Yil University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
SINGLE (Outcomes Assessor)

Intervention model description

1:1

Eligibility

Sex/Gender
ALL
Age
15 Years to 20 Years
Healthy volunteers
No

Inclusion criteria

* The presence of indication for both arches to be bonded in the same appointment

Exclusion criteria

* Presence of restorations, hypoplasia or decalcification on vestibular tooth surfaces * Abnormal crown morphology

Design outcomes

Primary

MeasureTime frameDescription
Transfer accuracy (composite outcome) in milimetres and degrees. Which is measured on computer software.Day 0 - Day 2The positional deviations between the attachments on the models and the mouth

Countries

Turkey (Türkiye)

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026