Anterior Chamber Depth Variability Between Two Lenses With Different Materials

Anterior Chamber Depth (ACD) Variability Between the Clareon and Acrysof IOL: a Randomised Trial

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03751215
Enrollment
50
Registered
2018-11-23
Start date
2018-10-01
Completion date
2019-12-01
Last updated
2019-04-19

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cataract

Keywords

Cataract, Cataract surgery, Intraocular lens

Brief summary

Compare the change of the Anterior chamber depth (ACD) variability between the Clareon and the AcrySof Intraocular lens (IOL) after implantation over 6 months.

Detailed description

Patients undergoing cataract surgery are often otherwise healthy and active with their only restriction being reduced visual quality. Within the past few years, intraocular lenses (IOLs) have been improved to fulfill the needs of these patients. Nowadays efforts are aiming for the enhancement of the patient vision and his subjective satisfaction postoperative. One of the best ways to accomplish this is to have a perfect intraocular lens (IOL) power calculation. However, the best calculation can't help if the implanted intraocular lens (IOL) changes its position after implantation. It should be considered that an anterior chamber depth (ACD) shift, decentration, tilt or rotation of an IOL could result in a reduction in visual quality. For an aspherical IOL, for instance, it is essential not to be decentrated and tilted more than 0.4 mm 2 (0.8 mm 3) and 7° 2 (10° 3), respectively. Otherwise it will be outperformed by a spherical IOL. The estimation of the post-operative intraocular lens (IOL) position and therefore the estimated anterior chamber depth (ACD) is presently the main source of error (35% 4 to 42% 5) in IOL power calculation and therefore for the refractive outcome of the patients after cataract surgery. Presently the pre-operatively measured ACD is taken into account for several IOL power calculation formulas, such as the Haigis formula, the Holladay II formula and the Olsen formula. To manage a better outcome an IOL with less postoperative influence of the anterior chamber depth (ACD) is very important. To accomplish a smaller deviation after the operation of the anterior chamber depth (ACD) the haptic and the material of the lens is very important. The change of the anterior chamber depth (ACD) after cataract surgery can be easily measured by instruments like the IOL-Master 700, AC-Master and Lenstar. It must be considered that every person is different and that change of the anterior chamber depth (ACD) in different eyes can cause high measurement errors. The changes in two eyes of the same patient help to minimize the error. These can help to achieve a better outcome for future patients. The hydrophobic acrylate of the Acrysof IOL has been modified to the new material in the Clareon IOL. This study will evaluate whether the new Clareon has non-inferior axial stability to the Acrysof.

Interventions

PROCEDURECataract surgery

During cataract surgery the patient is implanted with the monofocal IOL Clareon in one eye and the monofocal IOL AcrySof in the contralateral eye

Sponsors

Prim. Prof. Dr. Oliver Findl, MBA
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
21 Years to 105 Years
Healthy volunteers
No

Inclusion criteria

* Age-related cataract in both eyes * Scheduled for bilateral cataract surgery * Age 21 and older * Written informed consent prior to recruitment * Visual Acuity \> 0.05

Exclusion criteria

* Pregnancy (pregnancy test will be taken pre-operatively in women of reproductive age) * Any ophthalmic abnormality that could compromise visual function or the measurements * Presence of potential zonular weakness such as pseudoexfoliation Syndrome, history of ocular trauma, previous ocular surgery.

Design outcomes

Primary

MeasureTime frameDescription
Anterior chamber depth (ACD)12 monthsThe change in anterior chamber depth (ACD) before and after cataract surgery will be measured using the IOL Master 700 and compared between the two different IOLs.

Secondary

MeasureTime frameDescription
Distance visual acuity12 monthsUncorrected and corrected distance visual acuity will be determined using ETDRS-charts in a distance of 4 metres and differences in refraction will be compared between the two IOLs.