Skip to content

Reading Analysis in Ophthalmologic Patients

Reading Analysis in Ophthalmologic Patients: a Pilot Study

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03750149
Enrollment
100
Registered
2018-11-21
Start date
2018-01-01
Completion date
2021-01-01
Last updated
2019-02-27

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Age Related Macular Degeneration, Diabetic Maculopathy, Epiretinal Membrane, Glaucoma

Keywords

Diabetic Maculopathy, Age Related Macular Degeneration, Glaucoma, Epiretinal membrane, Reading analysis

Brief summary

Investigation of the reading parameters and fixation behavior in patients with different ocular diseases (age-related macular degeneration, glaucoma, diabetic maculopathy, epiretinal membrane) and healthy subjects. In addition, fixation analysis and retinal sensitivity measurements will be done with a microperimeter in each subject.

Detailed description

Reading is a complex function. It requires a proper retinal image that is received by the brain. There it is analyzed for letter and word recognition and then the semantics is detected. Reading speed slows down when letters are blurred, or do not have enough contrast or luminance or when binocular fusion is hampered. Hence, it is obvious that reading ability is reduced in patients with various ocular diseases. Especially, pathologies effecting the posterior pole (central and paracentral vision) might impair reading parameters significantly. Recently, the Eyetracker Eyelink 1000 (SR Research Ltd, Canada) became available. It´s application was described previously. Briefly, a high-speed infrared camera detects the position of eye (pupil and corneal reflex) and in turn the direction of gaze 500 times per second. During the calibration process the position can be linked to the position on a screen where, for instance, a text or a fixation target can be projected. Direction of gaze is recorded during the reading process and the gathered data are analyzed. Fixation ability was assessed using Eyelink 1000 in patients with age-related macular degeneration. It was shown that fixation is related to visual function. The worse eye showed reduced fixation ability which is improved during binocular fixation. This study investigates reading parameters in patients with various ocular diseases.

Interventions

Patients with various ophthalmologic diseases (ERM, glaucoma, AMD, diabetic retinopathy) will undergo reading analysis using the EyeTracker

Sponsors

Prim. Prof. Dr. Oliver Findl, MBA
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
21 Years to 105 Years
Healthy volunteers
Yes

Inclusion criteria

* Age 21 and older * Absence of ocular disease (Group 1) * Present ocular disease (age-related macular degeneration, glaucoma, diabetic maculopathy, epiretinal membrane/macular hole) as judged by the investigator (Group 2 - 5) * Maximum of allowed cylinder-power in the spectacles: +1.50D

Exclusion criteria

* Ocular pathologies, that may interfere with study measurements, such as corneal scars * In case of pregnancy (pregnancy test will be taken prior to inclusion into the study in women of reproductive age)

Design outcomes

Primary

MeasureTime frameDescription
Reading speed12 monthsReading speed (words per minute) will be analysed using the EyeTracker device. The patient has to read 4 texts with different contrast levels. The faster the patient can read a text, the better the results.

Secondary

MeasureTime frameDescription
Retinal perimetry12 monthsAnalysis of retinal fixation will be done using microperimetry.

Countries

Austria

Contacts

Primary ContactStefan Palkovits, MD
office@viros.at01 910 21-57573
Backup ContactSahand Amir-Asgari, MD
office@viros.at01 910 21-57557

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026