Skip to content

Correlation Between Core Temperature and Skin Temperature Measured by 3M SpotOn

Correlation Between Core Temperature and Skin Temperature Measured by 3M SpotOn

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03745079
Acronym
Temperature
Enrollment
80
Registered
2018-11-19
Start date
2019-09-20
Completion date
2023-12-31
Last updated
2023-03-06

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

General Anesthesia, Temperature

Brief summary

Core temperature should be monitored under general anesthesia. Recently developed 3M Spoton skin temeprature which is applied on temporal artery is correlated with core temperature measure by esophageal prove in several studies. Conventional skin temperature over carotid artery is also correlated with core temperature in several studies. The purpose of this study is comparing 3 methods of temperature monitoring. First, conventional core temperature measure by esophageal stethoscope. Second, 3M Spoton applying on temporal artery. Third, 3M Spoton applying on carotid artery

Detailed description

Core temperature should be monitored under general anesthesia. Because patients are prone to hypothermia during surgery. Conventional core temperature is monitored at esophagus, rectum, nasopharynx. But some of them are invasive and impossible in sometimes. Recently developed 3M Spoton skin temeprature which is applied on temporal artery is correlated with core temperature measured by esophageal prove in several studies. Its mechanism is making zero heat flux on skin applied. But it also cannot apply in head or facial surgery. Other studies showed conventional skin temperature over carotid artery is also correlated with core temperature. The investigators hypothesized using Spoton on carotid artery could be alternative method measuring core temperature. The purpose of this study is comparing 3 methods of temperature monitoring. First, conventional core temperature measure by esophageal stethoscope. Second, 3M Spoton applying on temporal artery. Third, 3M Spoton applying on carotid artery

Interventions

Measuring core temperature by esophageal stethoscope

OTHERSpoton Temporal

Mesuring temperature on skin near to temporal artery using Spoton

OTHERSpoton Carotid

Mesuring temperature on skin near to carotidl artery using Spoton

Sponsors

Ajou University School of Medicine
Lead SponsorOTHER

Study design

Observational model
OTHER
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
19 Years to 60 Years
Healthy volunteers
No

Inclusion criteria

* Age 19\ 60 years old * Who need surgery more than 2 hours under general anesthesia * American Society of Anesthesiologists physical status 1 or 2

Exclusion criteria

* Body mass index \< 35 * Head and neck surgery * Patients with fever \> 38'C * History of malignant hyperthermia

Design outcomes

Primary

MeasureTime frameDescription
Esophageal core temperature measured by stethoscope ℃3 hours (during general anesthesia)Temperature measured by esophageal stethoscope, ℃
Carotid skin temperature by SpotOn, ℃3 hours (during general anesthesia)Temperature measured by SpotOn near to carotid artery, ℃
Temporal skin temperature by SpotOn, ℃3 hours (during general anesthesia)Temperature measured by SpotOn near to temporal artery, ℃

Secondary

MeasureTime frameDescription
Room temperature, ℃3 hours (during general anesthesia)Operating room temperature, ℃

Countries

South Korea

Contacts

Primary ContactIn Kyong Yi, MD
lyrin01@hotmail.com+82312197522

Outcome results

None listed