Skip to content

XLIMus Drug Eluting Stent: a randomIzed Controlled Trial to Assess Endothelization

XLIMus Drug Eluting Stent: a randomIzed Controlled Trial to Assess Endothelization

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03745053
Acronym
XLIMIT
Enrollment
180
Registered
2018-11-19
Start date
2019-02-05
Completion date
2023-09-02
Last updated
2024-02-07

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Coronary Artery Disease

Brief summary

The objective of the study is to assess angiographic and clinical performance of Xlimus Drug Eluting Stent (DES) compared to Synergy Bioabsorbable Polymer Everolimus Eluting Stent in patients treated with percutaneous coronary angioplasty

Detailed description

The present clinical investigation is designed as a prospective, multicentre, international, randomized, open label, 2-arm parallel group, trial in patients undergoing Percutaneous Coronary Intervention (PCI) comparing Xlimus DES versus Synergy DES with respect to optical coherence tomography (OCT) derived measures at 6-month Follow Up (FU) and clinical events at 12 months after procedure. A total of 180 patients will be recruited and randomized in the two groups in a 2:1 ratio. After index procedure, patients will be followed up by angiographic follow-up at 6 months and clinical follow-up at 12 months.The primary endpoint will be independently evaluated by the Core-Lab which will be blinded as to group assignment

Interventions

DEVICEXlimus DES Implantation during coronary angioplasty

Xlimus DES Implantation during coronary angioplasty

DEVICESynergy DES Implantation during coronary angioplasty

Synergy DES Implantation during coronary angioplasty

Sponsors

Mediolanum Cardio Research
CollaboratorOTHER
Cardionovum GmbH
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
SINGLE (Outcomes Assessor)

Masking description

The members of the Event Adjudication Committee and the Core Lab will be blinded to the patient assignment.

Intervention model description

Randomized multi-centre controlled trial

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Age≥18 2. Documented coronary artery disease (CAD): stable or unstable angina, Non-ST segment MI. 3. PCI considered appropriate and feasible 4. Culprit de novo lesion in a native coronary artery with significant stenosis (\>50% by visual estimate) eligible for implantation with either study stent (no limitation on the number of treated lesions, vessel and lesion length); 5. Patient provides written informed consent 6. Patient agrees to all required follow-up procedures and visits. 7. Target lesion suitable for PCI with DES diameter between 2.5 and 4.0 mm

Exclusion criteria

1. The patient has a known hypersensitivity or contraindication to any of the following medications: heparin, aspirin, clopidogrel, ticlopidine, sirolimus or its derivatives, everolimus or structurally-related compounds, and/or contrast media (patients with documented sensitivity to contrast which can be effectively pre-medicated with steroids and diphenhydramine \[e.g. rash\] may be enrolled. Patients with true anaphylaxis to prior contrast media, however, should not be enrolled); 2. Known hypersensitivity to L605 cobalt chromium, 316L stainless steel, platinum, chromium, iron, nickel or molybdenum; 3. Known sensitivity to poly-lactic acid or poly(lactic-co-glycolic acid) polymer; 4. Female of childbearing potential, unless a recent pregnancy test is negative, who possibly plan to become pregnant any time after enrolment into this study and not using adequate contraceptive methods; 5. History of bleeding diathesis or known coagulopathy (including heparin-induced thrombocytopenia), or will refuse blood transfusions; 6. Previous coronary intervention on target vessel in the 3-months prior to enrollment; 7. Non-cardiac co-morbid conditions with life expectancy \<1 year or that may result in protocol non-compliance (per site investigator's medical judgment); 8. Patients who are actively participating in another drug or device investigational study, which have not completed the primary endpoint follow-up period; 9. Previously documented left ventricular ejection fraction (LVEF) \<30%; 10. Evident cardiogenic shock before randomization; 11. Patients with left main stem stenosis (\>50% by visual estimate); 12. In-stent restenosis; 13. ST-segment elevation MI; 14. Chronic total occlusion/ heavily calcified lesions 15. Culprit lesion to a Saphenous Vein graft

Design outcomes

Primary

MeasureTime frameDescription
In-stent neointimal volume6-month follow-upIn-stent neointimal volume at 6-month follow-up, measured with OCT, as assessed by the Core-Lab. Neointimal volume will be calculated in all analyzed cross-sections and volumetric measurements and in stent neointimal volume will be compared in the two groups.

Secondary

MeasureTime frameDescription
Number of Target lesion failure12-months follow-upcomposite of Cardiac death, target-vessel Myocardial infarction (MI) and clinically indicated target lesion revascularization (TLR)
Number of patients experiencig Cardiac death12-months follow-upAny death due to proximate cardiac cause (eg, MI, fatal arrhythmia), unwitnessed death and death of unknown cause, and all procedure-related deaths, including those related to concomitant treatment, will be classified as cardiac death
Number of Target-vessel Myocardial infarction12-months follow-upany MI that, irrespective of the time after the index procedure, is related to documented acute ischemia in the territory of the implanted stent without angiographic confirmation of stent thrombosis and in the absence of any other obvious cause. Type of acute MI is classified according to the Joint ESC/ACCF/AHA/ WHF Joint Task Force for the Universal Definition of Myocardial Infarction
Number of Target-lesion revascularization12-months follow-uprepeat revascularization will be defined as any repeat PCI or new coronary artery bypass graft (CABG) surgery within the first year post-PCI
Neointimal area6-month follow-upNeointimal area calculated at the site of minimal lumen area measured with OCT
Percentage of Device success at 24 hours24 hoursdeployment of the assigned stents without system failure or device-related complication
Percentage of Lesion success at 24 hours24 hoursattainment of \<50% residual stenosis of the target lesion using post-PCI
Percentage of Procedural success at 24 hours24 hourslesion success without the occurrence of major adverse cardiac event (MACE) during the hospital stay
Number of Stent thrombosis12-months follow-upThis is defined according to classification proposed by the Academic Research Consortium

Countries

Italy, Spain

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 21, 2026