Skip to content

Assessment of Heat Generation From Low Speed Drilling Without Irrigation

ASSESSEMENT OF LOW SPEED DRILLING WITHOUT IRRIGATION VERSUS CONVENTIONEL DRILLING WITH IRRIGATION REGARDING HEAT GENERATION AND PERI-IMPLANT MARGINAL BONE LOSS

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03743545
Enrollment
2
Registered
2018-11-16
Start date
2018-12-01
Completion date
2019-04-02
Last updated
2018-11-19

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Implant Site Reaction

Brief summary

ASSESSMENT OF LOW SPEED DRILLING WITHOUT IRRIGATION VERSUS CONVENTIONAL DRILLING WITH IRRIGATION REGARDING HEAT GENERATION AND PERI-IMPLANT MARGINAL BONE LOSS

Detailed description

Assessment of heat generation from conventional drilling speed for dental implant placement versus biological drilling (low speed without irrigation ) by thermocouples technology And measure the primary stability of dental implants placed by the two techniques by osstel device

Interventions

comparing between conventional implant placement drilling speed with irrigation and experimental arm (low speed without irrigation)

Sponsors

Cairo University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Intervention model description

healthy posterior mandible

Eligibility

Sex/Gender
ALL
Healthy volunteers
Yes

Inclusion criteria

both sex no intraoral soft and hard tissue pathology no systemic condition that contraindicate implant placement adult patients with proper posterior mandibular ridge requires implant placement

Exclusion criteria

presence of pathological lesions heavy smokers more than 20 cigarettes per day patients with systemic disease that may affect normal healing Patients with no enough bone in posterior mandible for implant placement

Design outcomes

Primary

MeasureTime frameDescription
Measurement of heat generation from low speed hand piece drills drilling by thermocouple technology6 monthsMeasurement of 3 different depths(mms). Data analyzed with a three-way analysis of variance by Newman-Keulsmultiple comparison procedure. The significance level was set to a p-value of 0.05.

Secondary

MeasureTime frameDescription
stability-osstell device to assess the primary stability of placed dental implant6 monthsResonance frequency analysis (RFA) allows assess implant stability by measuring implant oscillation frequency on the bone

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026