Skip to content

An Instrumented Wobble Board to Present the Distribution and Center of Pressure in Dynamic Balance

An Instrumented Wobble Board to Present the Distribution and Center of Pressure in Dynamic Balance

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03743506
Enrollment
30
Registered
2018-11-16
Start date
2017-11-06
Completion date
2018-12-12
Last updated
2019-07-05

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Balancing Interference

Keywords

Wobble board, center of pressure, dynamic balance, force platform

Brief summary

This study quantified the displacement of the center of pressure in the computer in real time and record this data for future analyzes

Detailed description

The wobble board is an unstable equilibrium platform, constant training on this platform generates an improvement in balance and strengthens the muscles, it is ideal for rehabilitation exercises and balance conditioning. However, these platforms do not provide quantitative data on exercises performed on it. And the force platform that provide this quantitative data is static, offering no difficulty in maintaining balance. In this way, a sensor board wobble board was developed using a conventional wobble board with a plate attached to it, between the plate and the platform are eight strain gauges sensors that are activated according to the position of the force applied on the platform, the values of the sensors are collected by software that demonstrates the point of greatest pressure on the disk and its displacement during the exercises, with this data it is possible to determine the stability of the user and observe their behavior during the exercises.

Interventions

DIAGNOSTIC_TESTWith feedback

To evaluate the displacement of the center of pressure on the disc during the equilibration with feedback.

DIAGNOSTIC_TESTWithout feedback

To evaluate the displacement of the center of pressure on the disc during the equilibration without feedback.

Sponsors

University of Mogi das Cruzes
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 45 Years
Healthy volunteers
Yes

Inclusion criteria

* Absence of musculoskeletal alteration in the lower limbs; * consent form signed by the volunteer; * with preserved cognitive

Exclusion criteria

* Present some impairment of the skeletal muscles of the lower limbs; * Present cognitive deficit.

Design outcomes

Primary

MeasureTime frameDescription
Pressure center displacement speed15 minutesThe velocity at which the center of pressure moves during the test, divided into two steps, with three repetitions at each step, with a rest of 30 seconds at each repetition, was measured. Unit of measure: Centimeters per second (cm / s).

Secondary

MeasureTime frameDescription
Longest distance between points on X and Y axis15 minutesIt was measured at the greatest distance of the center of pressure displacement on the X and Y axis during the test, divided into two steps, with three repetitions at each stage, with a rest of 30 seconds at each repetition. Unit of measurement: Centimeters (cm).

Countries

Brazil

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026