Skip to content

Positive Airway Pressure Under Apnoeic Oxygenation With Different Flow Rates in Nasal Cannula Therapy

Positive Airway Pressure Under Apnoeic Oxygenation With Different Flow Rates

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03738722
Acronym
PAPUA-Flow
Enrollment
28
Registered
2018-11-13
Start date
2019-01-10
Completion date
2019-03-31
Last updated
2019-10-02

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Apnoeic Oxygenation

Brief summary

The main objective of this explorative observational study is to investigate the pressures in infraglottic airway and the pharynx provided by THRIVE , using flows ranging from 1l/min to 80 l/min, in patients hospitalized for elective surgical procedure; to investigate the correlation between airway pressure and nasal oxygen flow.

Detailed description

Eligible adults with written informed consent will be monitored for general anaesthesia according standard operating procedure of the Bern University Hospital's anaesthesia department. Additional non-invasive monitoring for this study are transcutaneous measurement of carbon dioxide and oxygen (TCM 5®, Radiometer, Krefeld, Germany), NarcotrendTM ( Narcotrend-Group, Hannover, Germany)and thoracic electrical impedance tomography (EIT, PulmoVista® 500, Draeger, Luebeck, Germany). Normal pre-oxygenation (until end expiratory carbon dioxide is \> 90% or time \> 3 minutes) will occur. Anaesthesia will be started using a target -controlled infusion system for Propofol and Remifentanil, using NarcotrendTM to measure depth of anaesthesia. All patients will receive a standard dose of neuromuscular blockage to facilitate airway management and total intravenous anaesthesia will be installed. Using the train of four measurement (TOF) full neuromuscular blockage with Rocuronium will be confirmed every 30 seconds. After administration of rocuronium, proper bag-mask ventilation will be confirmed. Intratracheal pressure will be measured by 11 Fr. catheter (Cook Medical, Bloomington, IN, USA), connected to a CODAN Xtrans®-transducer (CODAN ARGUS Ag, Baar, Switzerland). A 11 Fr. catheter (Cook Medical, Bloomington, IN, USA) will be introduced oral in the trachea facilitated by video-laryngoscopy. To ensure patency of the upper airway jaw thrust via Esmarch manoeuvre will be applied and flexible bronchoscopy will confirm upper airway patency. Initially this 11 Fr. catheter will be positioned in the right main bronchus (2 cm below the carina). The first measurement will be performed with a randomized sequence of flow rates of 80, 60, 40, 20 or 1 l/min with opened and closed mouth. Each pressure measurement will be performed after a stable pressure plateau of 10 seconds will be observed. The catheter will then be retracted and the pressure quantification are performed with the same sequence, defined above, in different positions (50% of trachea length and pharyngeal pressures 10 cm from upper front teeth). The order of flow and mouth opening will be randomized. The study intervention will end when all measurements are taken or upper airway patency cannot be ensured under direct endoscopy view. If one of the following criteria is met: peripheral oxygen saturation (SpO2) \<92% or transcutaneous carbon dioxide (PtCO2) \>80mmHg, immediately bag mask ventilation will be initiated, until normal values of SpO2 and PtCO2 are reached. When any of the end points is reached, normal anesthesiologic care will be established as planned. A safety interview will be conducted on the first post-operative day to evaluate injuries during airway management (e.g. bleeding, sore throat, hoarseness, lip injuries), pain, postoperative nausea and vomiting.

Interventions

DRUGOxygen

HFNCT (high flow nasal cannula therapy) will be provided using OptiFlow by Fisher&Paykel.

Sponsors

University of Bern
CollaboratorOTHER
Insel Gruppe AG, University Hospital Bern
Lead SponsorOTHER

Study design

Intervention model
SEQUENTIAL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* \> 18 years * Written informed consent * Undergoing elective surgery * Requiring general anesthesia * ASA 1-3 (American Society of Anesthesiologists)

Exclusion criteria

* Any Indication for fibre optic intubation * Expected impossible mask ventilation * Known coronary heart disease * Known heart failure, NYHA classification( New York Heart Association ) ≥ 2 * Peripheral occlusive arterial disease, Fontaine ≥ 2b * BMI \> 30kg/m2 and BMI \< 16kg/m2 * Hyperkalaemia (K \> 5.5 mmol/l) * Known COPD (Chronic obstructive pulmonary disease) Gold classification ≥ 2 * Known pulmonary arterial hypertension, systolic \> 35mmHg * Known obstructive sleep apnoea syndrome in need of therapy * High risk of aspiration * Increased intracranial pressure * Intracranial surgery * Limited knowledge of German language * Absent power of judgement * Pregnancy (pregnancy test before inclusion) * Neuromuscular disorder * Known or suspected cervical spine instability * Nasal obstruction, impossibility of nasal ventilation (both sides patent) * Allergies or contra-indications to one or more of the used anaesthesia agents

Design outcomes

Primary

MeasureTime frameDescription
Mean positive airway pressure during Apnoea (approx.10 min) with HFNCT (High-Flow-Nasal-Cannula-Therapy)After induction of anaesthesia; Each pressure measurement (main bronchus,trachea, pharynx) will be performed after a stable pressure plateau of 10 sec. will be observed; until all measurements are taken or upper airway patency cannot be ensuredMeasurement of the mean positive airway pressure in cm H2O during apnoea time in the pharynx (10cm distal upper front teeth), in the trachea (50% length) and in the right main bronchus (2cm distal carina), with different flow-rates (80l/min, 60l/min, 40l/min, 20l/min, 1l/min), with opened and closed mouth

Secondary

MeasureTime frameDescription
Changes in ptcO2 and ptcCO2 in mmHg/minAfter induction of anaesthesia, during apnoea period; until all pressure measurement (main bronchus,trachea, pharynx) are taken or upper airway patency cannot be ensuredTranscutaneous measurement
Upper airway patencyAfter induction of anaesthesia, during apnoea period; until all pressure measurement (main bronchus,trachea, pharynx) are taken or upper airway patency cannot be ensuredFlexible bronchoscopy will confirm upper airway patency: Open or closed
Changes in electrical impedance tomography. (EIT)After induction of anaesthesia, during apnoea period; until all pressure measurement (main bronchus,trachea, pharynx) are taken or upper airway patency cannot be ensuredEIT will be continuously measured using PulmoVista® 500 visualizing possible atelectasis formation.

Countries

Switzerland

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026