Cardiac Output Monitoring by ccNexfin© in Pregnant Women

Continuous Non-invasive Cardiac Output, an Evaluation of ccNexfin© in a Pregnant Population

Status
Completed
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03735043
Acronym
CoNex
Enrollment
100
Registered
2018-11-08
Start date
2019-07-02
Completion date
2020-06-01
Last updated
2026-04-27

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Pregnancy

Keywords

Pregnancy, ccNexfin©, cardiac output, hemodynamic, non-invasive monitoring

Brief summary

Variations of cardiac output are frequent in pregnant women during obstetrical procedures, and may participate to poor foetal outcomes through decrease of uteroplacental bloodflow. Thus, monitoring maternal cardiac output appears of major interest, as it would open the way to early initiation of hemodynamic supportive management. The ccNexfin© is a non-invasive hemodynamic monitoring device, whose relevance for continuous monitoring of cardiac output has been reported in a non-pregnant population. The hypothesis is that ccNexfin© gives acceptable measurement of maternal cardiac output in pregnant women.

Interventions

DEVICEcardiac output by ccNexfin ©

Measurement of cardiac output by ccNexfin © comparatively to transthoracic echocardiography Subjects participating to the study will be simultaneously measured for cardiac output by ccNexfin © and transthoracic echocardiography. Echocardiographic measurements of cardiac output will be blinded to values measured by ccNexfin ©. For each participant, a first measurement of cardiac output will be performed in the supine position and then after 1 minute of strict left lateral position.

Sponsors

University Hospital, Lille
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
FEMALE
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Pregnancy \> 32 weeks of amenorrhea * Informed consent to participate to the study * Health insurance

Exclusion criteria

* Poor echogenicity for Transthoracic echocardiography * Cardiopathy * Difficulties to move * Necessity of strict supine or lateral position * Impossibility to receive information or to give inform consent to participate to the study Refusal to sign inform consent

Design outcomes

Primary

MeasureTime frame
Intra-class correlation coefficient between values of supine position cardiac output evaluated simultaneously by transthoracic echocardiography (measured in liters / minute) and ccNexfin © (measured in liters / minute)1 minute after positioning in supine position

Secondary

MeasureTime frame
Cohen's Kappa coefficient between changes in maternal ejection volume observed from supine position to left lateral position, evaluated by transthoracic echocardiography (in %) and ccNexfin © (in %) respectively, at the 10% threshold of variationMaternal ejection volume in supine position: 1 minute after positioning in supine position Maternal ejection volume in left lateral position: 1 minute after positioning in left lateral position
Cohen's Kappa coefficient between changes in maternal cardiac output observed from supine position to left lateral position, assessed by transthoracic echocardiography (in %) and ccNexfin © (in %) respectively, at the 15% threshold of variationMaternal cardiac output in supine position: 1 minute after positioning in supine position Maternal cardiac output in left lateral position: 1 minute after positioning in left lateral position
Intra-class correlation coefficient between left lateral position cardiac output values assessed simultaneously by transthoracic echocardiography (measured in liters / minute) and ccNexfin © (measured in liters / minute)1 minute after positioning in left lateral position
Pearson correlation coefficient between values of supine position maternal cardiac output evaluated by transthoracic echocardiography (measured in liters / minute) and ccNexfin © (measured in liters / minute), respectively1 minute after positioning in supine position
Pearson correlation coefficient between values of left lateral position maternal cardiac output evaluated by transthoracic echocardiography (measured in liters / minute) and ccNexfin © (measured in liters / minute), respectively1 minute after positioning in left lateral position

Countries

France

Contacts

PRINCIPAL_INVESTIGATORAlexandre GAUDET, MD

University Hospital, Lille

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Apr 28, 2026