Skip to content

Non-invasive Limb Compartment Pressure Measurement

Non-invasive Limb Compartment Pressure Measurement

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03730688
Acronym
FNO-TRAUMA-CPM
Enrollment
70
Registered
2018-11-05
Start date
2018-09-01
Completion date
2021-12-31
Last updated
2022-12-07

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Burn Injury, Compartment Syndromes, Polytrauma

Keywords

compartment syndrome, compartment pressure, polytrauma, burn injury, limb ischemia, fasciotomy

Brief summary

Compartment syndrome (CS) is a serious complication of soft-tissue injuries in patients with fractures of the musculoskeletal apparatus. CS is defined as a condition, during which an increased tissue pressure inside an enclosed compartment damages the microcirculation and neuromuscular function of the tissue, and results in ischemization, with a damage of nerve-muscle structures, which lead either to extensive flexion contractures, or myonecroses, with the need to perform an early amputation of the affected limb. In traumatology, compartment syndrome is most frequently observed in a patient with crural fractures, closed as well as open fractures, or in cases of crus laceration.

Detailed description

Compartment syndrome (CS) is a serious complication of soft-tissue injuries in patients with fractures of the musculoskeletal apparatus. CS is defined as a condition, during which an increased tissue pressure inside an enclosed compartment damages the microcirculation and neuromuscular function of the tissue, and results in ischemization, with a damage of nerve-muscle structures, which lead either to extensive flexion contractures, or myonecroses, with the need to perform an early amputation of the affected limb. In traumatology, compartment syndrome is most frequently observed in patients with crural fractures, closed as well as open fractures, or in cases of crus laceration. Diagnostics of the compartment syndrome is very difficult, even today, when numerous emergency osteosyntheses are performed, as it depends not only on the clinical examination of the injured patient but also upon subjective symptoms, which may not be always clearly apparent and objectively quantifiable in a disoriented patient with concussion, or in an unconscious patient. At present, intracompartmental pressure is measured with invasive techniques only (with the insertion of the measurement needle into the compartment space, and administration of saline), or invasively, using piezoelectric probes, similarly to a measurement of pressure in vessels. Both these techniques are invasive, and as such may be associated with complications (infection at the puncture site, increase of intracompartmental pressure with administration of the measuring liquid, or formation of haematoma and bleeding at the probe site). Physiological values of intracompartmental pressure vary between 5 and 10 mmHg, in case an increase over 20 mmHg is observed, emergency dermatofasciotomy is indicated. The presented project is aimed at comparing the invasive and non-invasive techniques of compartment syndrome measurement. The aim of the project is to develop a new non-invasive examination technique of intracompartmental pressure measurement in soft tissues of the injured extremity, with the possibility of its observation and continuous monitoring of the measured values. Partial aims 1. Invasive measurement of limb intracompartmental pressure. 2. Development of a new examination technique for non-invasive measurement of the compartment syndrome, in cooperation with researchers from the Technical University Ostrava 3. Measurement of compartment syndrome using the new non-invasive examination technique and monitoring of data Methods First of all, compartmental pressures in the limbs will be performed using the invasive technique. The measurement will be performed also in cases when a fasciotomy was indicated and performed, and the authors will monitor the decrease of compartmental pressure in the course of treatment. Individual measurements will be recorded and statistically analyzed. In the course of measurement, the researchers will work upon the development of a new non-invasive examination technique, which will be intended for non-invasive measurement of compartmental pressure. The research team will also compare both these techniques, and assess the advantages and disadvantages of each of the techniques used. Statistical data processing Results of measurements of compartmental pressure using individual techniques will be statistically evaluated, depending on the clinical findings at the injured extremity.

Interventions

DEVICEConventional compartment pressure measurement

Compartment pressure will be measured using the conventional compartment pressure measurement system.

DEVICEExperimental compartment pressure measurement

Compartment pressure will be measured using the newly-developed compartment pressure measurement system.

Sponsors

University Hospital Ostrava
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Masking description

No masking will be used in the study.

Intervention model description

Compartment pressure will be measured in a single group of patients, using the conventional and the newly developed experimental means of measurement.

Eligibility

Sex/Gender
ALL
Age
15 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* polytrauma * monotrauma * burn injury

Exclusion criteria

* age below 15 years of age * skin infection at the area of measurement * limb-loss trauma

Design outcomes

Primary

MeasureTime frameDescription
A 30% decrease of complications related to compartment pressure measurement37 monthsThe number of complications related to compartment pressure measurement will be observed for both interventions, with the target of achieving a 30% decrease.

Countries

Czechia

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026