Skip to content

TRICUS STUDY - Safety and Efficacy of the TricValve® Device

TRICUS STUDY - Safety and Efficacy of the TricValve® Transcatheter Bicaval Valves System in the Superior and Inferior Vena Cava in Patients With Severe Tricuspid Regurgitation.

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03723239
Enrollment
9
Registered
2018-10-29
Start date
2018-09-12
Completion date
2021-11-15
Last updated
2022-04-20

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Severe Tricuspid Regurgitation

Keywords

Tricuspid Valve Insufficiency, Heart Valve Diseases, Heart Diseases, Cardiovascular Diseases

Brief summary

The TricValve® Transcatheter Bicaval Valves System is indicated for relief of tricuspid insufficiency in patients with symptomatic heart disease who are judged by a heart team, including a cardiac surgeon, to be at extreme risk or inoperable for open surgical therapy.

Detailed description

TricValve® Transcatheter Bicaval Valves is a system of two self-expanding biological valves for the treatment of patients with hemodynamically relevant tricuspid insufficiency and caval reflux. The prostheses are implanted percutaneously into the inferior and superior vena cava without disturbing the native tricuspid valve. It is especially intended for use for patients at extreme risk or who are inoperable for open surgical therapy. Pre-Clinical and Clinical preliminary studies have shown an acceptable safety and performance profile of the TricValve® Transcatheter Bicaval Valves System. Given that the medical device is a potential long-term treatment for patients with tricuspid insufficiency, clinical data for long-term treatment periods is necessary. Thus, the current study is designed to investigate the safety and performance for at least 30 days and up to 6 months. The study has been approved by the Kaunas Regional Biomedical Research Ethics Committee.

Interventions

The TricValve® Delivery System is inserted from the femoral vein to access the inferior vena cava (IVC) and superior vena cava (SVC) of the heart under fluoroscopy guidance. The appropriately sized TricValve® is unsheathed at the implantation site and positions itself as per the anatomy - self expanding frame.

Sponsors

P+F Products + Features GmbH
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. The subject must be 18 years of age or older 2. The subject must be a patient with severe symptomatic tricuspid regurgitation demonstrated by echocardiography with significant backflow in the lower (IVC) and/or upper (SVC) vena cava and with a v-wave ≥ 25 mmHg as demonstrated by right heart catheterization (measured in the IVC and/or SVC 2-4 cm above/ below right atrium (RA) inflow) within 8 weeks prior to the implantation 3. Suitable for TricValve® Transcatheter Bicaval Valves System implantation according to anatomic criteria by computed tomography 4. The subjects must have severe, tricuspid regurgitation leading to New York Heart Association (NYHA) class III or IV 5. The subject has left ventricular ejection fraction (LVEF) ≥ 40% 6. Distance covert in 6-minute walk test (6MWT) ≥ 60m 7. The patient shall be screened by a Heart Team - including an interventional cardiologist, cardiothoracic surgeon, and agreed as a candidate for the TricValve® Transcatheter Bicaval Valves System implantation 8. Patient/authorized legal guardian understands the nature of the procedure, is willing to comply with associated follow-up evaluations, and provides written informed consent Patient/patient's authorized legal guardian is geographically stable (or willing to return for required study follow-up) and understands and is willing to fulfil all of the expected requirements of the clinical protocol

Exclusion criteria

1. Known significant intracardiac shunt (e.g. ventricular septal defect) or congenital structural heart disease based on heart teams decision 2. Requirement for other elective cardiac procedures e.g. Percutaneous Coronary Intervention (PCI) or Coronary Artery Bypass Graft (CABG) up to 90 days after the procedure or 30 days before the procedure 3. Right ventricular failure (TAPSE ≤13mmHg) 4. Systolic pulmonary arterial pressure \> 65 mmHg as assessed by Doppler echocardiography 5. Presence of any known life threatening (noncardiac major or progressive disease), non-cardiac disease that will limit the subject's life expectancy to less than one year 6. Cerebro-vascular event within the past 3 months 7. History of mitral/tricuspid endocarditis within the last 12 months 8. Patient has untreated significant left sided valvular heart disease which requires treatment (e.g. mitral regurgitation or stenosis, and aortic regurgitation or stenosis) 9. Documented primary coagulopathy or platelet disorder, including thrombocytopenia (absolute platelet count \<90k) 10. Documented evidence of significant renal dysfunction (serum creatinine \> 3.0mg/dl) or on any form of dialysis at time of screening within the last 4 weeks 11. Contraindication or known allergy to device's components, anti-coagulation therapy with vitamin K antagonists or contrast media that cannot be adequately premedicated 12. Patients unsuitable for implantation because of thrombosis of the lower venous system or vena cava filter 13. The patient has contraindication against a transesophageal echo (TEE) during the procedure 14. Evidence of an acute myocardial infarction (AMI) ≤ 1 month (30 days) 15. Liver cirrhosis Child C (see appendix) 16. Female patient of child-bearing potential 17. Psychiatric or behavioural disease including known alcohol or drug abuser that is likely to impair compliance with protocol 18. Currently participating in another study of an investigational drug or device that would directly impact the treatment or outcome of the current study 19. Requirement for Antibiotic Treatment within the last 48 hours

Design outcomes

Primary

MeasureTime frameDescription
Percentage of participants with major adverse events30 daysThe percentage of participants with major adverse events (death, myocardial infarction, cardiac tamponade, cardiac surgery for failed TricValve® implantation, stroke. Major bleeding according to Valve Academic Research Consortium (VARC) criteria)
Change of New York Heart Association (NYHA) functional class6 monthsChange of New York Heart Association (NYHA) functional class from III or IV to a lower one

Secondary

MeasureTime frameDescription
Cusp insufficiencyUp to 30 days, up to 6 monthsThe change of the degree of cusp insufficiency as assessed with echocardiography (ordinal) from a higher to a lower value
Device successUp to 30 days, up to 6 monthsDevice success as measured by number of patients who are alive with intended device in place with no additional surgical or interventional procedures related to the TricValve®.
Successful implantationUp to Discharge (≤ 10 days post index procedure)The percentage of surviving participants with successful access, delivery and retrieval of the device delivery system, and deployment and correct positioning of the intended device(s), and no need for additional unplanned or emergency surgery or re-intervention related to the device or access procedure.
6 Minute Walk TestUp to 30 days, up to 6 monthsImprovement in distance (m) in the 6 Minute Walk Test
Kansas City Cardiomyopathy Questionnaire (KCCQ)Up to 30 days, up to 6 monthsNumber of Patients with improvement in quality of life as assessed by Kansas City Cardiomyopathy Questionnaire (KCCQ, a 23-item, self-administered instrument that quantifies physical function, symptoms (frequency, severity and recent change), social function, self-efficacy and knowledge, and quality of life. Range of 0-100, in which higher scores reflect better health status.)
NYHA functional classUp to 30 daysNumber of Patients with improvement of NYHA functional class
Unrestricted movement of cuspsUp to 30 days, up to 6 monthsThe percentage of medical devices with unrestricted movement of cusps after implantation as assessed with echocardiography (nominal)

Countries

Lithuania

Outcome results

None listed