Skip to content

Comparison of McGrath and Macintosh Laryngoscopes for Insertion of a Double Lumen Tube by Residents

Comparison of McGrath and Macintosh Laryngoscopes for Insertion of a Double Lumen Tube by Residents

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03710096
Acronym
MacGrathDES
Enrollment
148
Registered
2018-10-17
Start date
2018-11-04
Completion date
2019-08-08
Last updated
2022-11-04

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Thoracic Injuries

Keywords

Mac Grath, Double lumen tube

Brief summary

The insertion of double lumen tube is difficult even more if it is a resident with no experience. we think that using videolaryngoscopes for novice ones would facilitate insertion of double lumen tube thanks to the visualization on a LCD screen of the laryngeal structure.

Interventions

DEVICEmacGrath

in the mac grath group we use the videolaryngoscope macGrath as first-line for the insertion of double lumen tube

DEVICEMacintosh's

in the macintosh group we use the laryngoscope with Macintosh's blade as first-line for the insertion of double lumen tube

Sponsors

University Hospital, Lille
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
OTHER
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Thoracic Surgery * Insertion of double lumen tube

Exclusion criteria

* Emergency surgery * Risk of inhalation * Person unable to consent * Persons deprived of liberty, under guardianship or trusteeship * Pregnant or lactating woman * Allergy to Tracrium, Propofol, Sufentanil

Design outcomes

Primary

MeasureTime frameDescription
Rate of success of intubation in both groups at the first attemptBaseline: one sessionthe success is defined as a correct implementation of the probe endotracheal in double light by an internal of anesthesia in the 1st attempt.

Secondary

MeasureTime frameDescription
Individual Determination of Cormack StageBaseline: one sessionscoring system for the grading of direct laryngoscopy in case of tracheal intubation is difficult
Rate of good positioning of double lumen tube confirmed by fibroscopyBaseline: one session
The rate of patients with an increase in systolic blood pressure of more than 20% compared to the measurement before insertion of the probeBaseline: one session
Intubation timeBaseline: one session
The rate of patients with pharyngeal pains upon awakeningBaseline: one session

Countries

France

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026