Skip to content

BIONICS 38 mm Trial EluNIR Ridaforolimus Eluting Coronary Stent System (EluNIR) In Coronary Stenosis Trial

Prospective, Multi-center, Single-arm, Open-label Clinical Trial, to Further Assess the Safety and Efficacy of Long (38 mm) Ridaforolimus Eluting Stent - EluNIR

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03702608
Enrollment
50
Registered
2018-10-11
Start date
2018-11-14
Completion date
2020-04-30
Last updated
2020-10-28

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Coronary Stenosis

Brief summary

This is a prospective, multi-center, single-arm, open-label clinical trial. Clinical follow-up will be performed at 30 days. Follow-up by phone will be performed at 6 months, and 1 year after the procedure. Study Objective is to further assess the safety and efficacy of long (38 mm) Ridaforolimus Eluting Stent - EluNIR.

Interventions

The EluNIR Ridaforolimus Eluting Coronary Stent System is a single use device/drug combination product comprising of: * Stent - a mounted Cobalt Chromium (CoCr) alloy based stent - 38 mm length and 2.75mm, 3.0 mm, 3.5mm, 4.0mm diameter * Delivery System - Rapid Exchange (RX) Coronary System * Polymer matrix coating - (PBMA) and CarboSil® * Ridaforolimus drug

Sponsors

Medinol Ltd.
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
OTHER
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* General Inclusion Criteria: 1. Age ≥ 18 years. 2. Patient with an indication for PCI including angina (stable or unstable), silent ischemia (in absence of symptoms a visually estimated target lesion diameter stenosis of ≥70%, a positive non-invasive stress test, or FFR ≤0.80 must be present), NSTEMI, or recent STEMI. For STEMI the time of presentation to the first treating hospital, whether a transfer facility or the study hospital, must be \>24 hours prior to enrollment and enzyme levels (CK-MB or Troponin) demonstrating that either or both enzyme levels have peaked. 3. An attempt (whether successful or not) was made to implant a 38 mm EluNIR stent (Stent was advanced beyond the guiding catheter). 4. Non-target vessel PCI are allowed prior to the screening for eligibility depending on the time interval and conditions as follows: 1. During Baseline Procedure: PCI of non-target vessels performed during the baseline procedure itself immediately prior to screening for eligibility, if successful and uncomplicated defined as: \<50% visually estimated residual diameter stenosis, TIMI Grade 3 flow, no dissection ≥ NHLBI type C, no perforation, no persistent ST segment changes, no prolonged chest pain, no TIMI major or BARC type 3 bleeding. 2. Less than 24 hours prior to Baseline Procedure: Not allowed (see

Exclusion criteria

#2). c. 24 hours-30 days prior to Baseline Procedure: i. PCI of non-target vessels 24 hours to 30 days prior to the baseline procedure if successful and uncomplicated as defined above. ii. In addition, in cases where non-target lesion PCI has occurred 24-72 hours prior to the baseline procedure, at least 2 sets of cardiac biomarkers must have been drawn at least 6 and 12 hours after the non-target vessel PCI. iii. If cardiac biomarkers are initially elevated above the local laboratory upper limit of normal, serial measurements must demonstrate that the biomarkers are falling. d. Over 30 days prior to Baseline Procedure: PCI of non-target vessels performed greater than 30 days prior to baseline procedure whether or not successful and uncomplicated. 5. Patient or legal guardian is willing and able to provide informed written consent and comply with follow-up visits and testing schedule. Angiographic inclusion criteria (visual estimate): 6. Target lesion(s) must be located in a native coronary artery or bypass graft conduit with visually estimated diameter of ≥2.75 mm to ≤4.25 mm. 7. Complex lesions are allowed including calcified lesions (lesion preparation with scoring/cutting and rotational atherectomy are allowed), presence of thrombus, CTO, bifurcation lesions, ostial RCA lesions, tortuous lesions, bare metal stent restenotic lesions, protected left main lesions, and saphenous vein graft lesions. 8. Overlapping stents are allowed as long as the first stent implanted is the EluNIR 38 mm long stent

Design outcomes

Primary

MeasureTime frameDescription
Primary Endpoint: Device Success30 dayDevice success is defined as achievement of a final in-stent residual diameter stenosis of \<50% (by QCA), using the assigned device only and without a device malfunction.
Primary Endpoint: No 30 Day MACE (Major Adverse Cardiac Events)30 DayNo 30 day MACE: MACE (Major Adverse Cardiac Events) is defined as the composite of cardiac death, any MI, or ischemia-driven TLR.

Countries

Israel

Participant flow

Participants by arm

ArmCount
EluNIR 38mm
Patients received the EluNIR Ridaforolimus Eluting Coronary Stent System: The EluNIR Ridaforolimus Eluting Coronary Stent System is a single use device/drug combination product comprising of: * Stent - a mounted Cobalt Chromium (CoCr) alloy based stent - 38 mm length and 2.75mm, 3.0 mm, 3.5mm, 4.0mm diameter * Delivery System - Rapid Exchange (RX) Coronary System * Polymer matrix coating - (PBMA) and CarboSil® * Ridaforolimus drug
50
Total50

Baseline characteristics

CharacteristicEluNIR 38mm
Age, Categorical
<=18 years
0 Participants
Age, Categorical
>=65 years
23 Participants
Age, Categorical
Between 18 and 65 years
27 Participants
Race (NIH/OMB)
American Indian or Alaska Native
0 Participants
Race (NIH/OMB)
Asian
0 Participants
Race (NIH/OMB)
Black or African American
0 Participants
Race (NIH/OMB)
More than one race
0 Participants
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
0 Participants
Race (NIH/OMB)
Unknown or Not Reported
0 Participants
Race (NIH/OMB)
White
50 Participants
Region of Enrollment
Israel
50 participants
Sex: Female, Male
Female
12 Participants
Sex: Female, Male
Male
38 Participants

Adverse events

Event typeEG000
affected / at risk
deaths
Total, all-cause mortality
0 / 49
other
Total, other adverse events
15 / 49
serious
Total, serious adverse events
5 / 49

Outcome results

Primary

Primary Endpoint: Device Success

Device success is defined as achievement of a final in-stent residual diameter stenosis of \<50% (by QCA), using the assigned device only and without a device malfunction.

Time frame: 30 day

ArmMeasureValue (COUNT_OF_PARTICIPANTS)
EluNIR 38mmPrimary Endpoint: Device Success44 Participants
Primary

Primary Endpoint: No 30 Day MACE (Major Adverse Cardiac Events)

No 30 day MACE: MACE (Major Adverse Cardiac Events) is defined as the composite of cardiac death, any MI, or ischemia-driven TLR.

Time frame: 30 Day

ArmMeasureValue (COUNT_OF_PARTICIPANTS)
EluNIR 38mmPrimary Endpoint: No 30 Day MACE (Major Adverse Cardiac Events)44 Participants

Source: ClinicalTrials.gov · Data processed: Feb 9, 2026