Skip to content

High Intensity Interval Training Versus Circuit Training

The Effects of Low-Volume High Intensity Interval Training and Circuit Training on Maximal Oxygen Uptake

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03700671
Enrollment
42
Registered
2018-10-09
Start date
2016-05-11
Completion date
2017-12-13
Last updated
2020-02-17

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

High Intensity Interval Training

Brief summary

High intensity interval training (HIIT) and circuit training (CT) are popular methods of exercise, eliciting improvements in cardiorespiratory fitness (CRF). However direct comparisons of these two training methods are limited.

Detailed description

Study Design Participants were enrolled in a randomised control trial at the University of Hull to either eight weeks of High intensity interval training (HIIT) or Circuit Training (CT) (two supervised sessions per week, accompanied by an exercise physiologist). A sample size of 38 using G Power 3.1 software was calculated based on previously published data in which the mean difference between HIIT and Moderate Intensity Continuous Training (MICT) was 3.2 ml.kg-1.min-1 with a pooled standard deviation of 3 ml.kg-1.min-1. Statistical significance was set at 0.05 and power set to 0.95. To allow for 10% attrition 42 individuals were recruited to the study. To assess the effectiveness of the interventions as determined by maximal oxygen consumption (VO2max), a maximal cardiopulmonary exercise test (CPET) to volitional exhaustion on an electronically braked cycle ergometer at baseline (visit one), and following an eight-week exercise intervention of HIIT or CT (visit two) was conducted. When attending the assessments participants were asked not to take part in any strenuous exercise 24 hours prior to the appointment, to wear suitable comfortable clothing and avoid a large meal. Visit two CPET was performed within six days of completing the exercise interventions. A thorough warm-up and cool down before and after each exercise session. All were asked to maintain their habitual physical activity patterns during the intervention. Body mass index (BMI) was calculated by dividing body weight by height in meters squared and was presented as kg.m-2. Resting blood pressure was measured after 15 minutes of rest using a sphygmomanometer (A.C. Cossor & Son Ltd, London UK) and stethoscope (3M Healthcare, St Paul, MN). To provide a comprehensive account of the study the Consensus on Exercise Reporting Template (CERT) was consulted. Participants Ethical approval was provided by the School of Life Sciences ethics committee at the University of Hull which was in accordance with the 1964 Helsinki declaration and its later amendments or comparable ethical standards. A total of 42 apparently healthy men and women between the age of 18-65 years were recruited to the study. Enrolled individuals reported no medical history of cardiometabolic or limiting respiratory disease, were non-smokers, had a body mass index \<30 kg.m-2, classified as recreationally active and none were taking any medication that would affect heart rate. As a condition of enrolment, those over 45 years obtained written medical clearance from a general practitioner and underwent resting and exercise 12-lead electrocardiogram (ECG) (GE Healthcare, Chalfont St Giles, United Kingdom). Written informed consent and a pre-exercise medical questionnaire was completed by all. Cardiopulmonary Exercise Testing Maximal CPETs were conducted in accordance with the American Thoracic Society (ATS) and the American College of Chest Physicians (ACCP) guidelines. An Oxycon pro (Jaeger, Hoechburg, Germany) breath by breath metabolic cart was used to collect respiratory gas exchange data. Automatic and manual calibration evaluated ambient temperature, humidity, barometric pressure and altitude. Calibration of the air flow volume was conducted using a 3 litre syringe and by automatic calibration. Two-point gas calibration was also conducted to ensure accurate measures of inspired oxygen and expired carbon dioxide. Tests were performed on a GE e-bike ergometer (GE Healthcare, Buckinghamshire, UK) using a ramp protocol. The protocol consisted of a three-minute rest phase, three minutes of unloaded cycling, followed by a personalised ramp test (ramp rate ranged between 15 and 30 watts) with work rate continually increased every one to three seconds. Participants performed the same ramp rate pre and post testing. Participants were asked to pedal at a cadence of 70 rpm until they reached volitional exhaustion at a protocol duration between eight to twelve minutes. Self-reported rating of perceived exertion (RPE) scores using the 6-20 scale and heart rate (HR) (FT1 heart rate monitor, Polar Electro, Finland) was recorded during the last five seconds of each minute of the test, at maximum exercise and during the recovery period. Together with verbal encouragement to volitional exhaustion, VO2max was attained by participants achieving at least two of the following criteria, VO2 plateau as determined by a failure of VO2 increase by 150 ml/min with further increases in workload analysed by breath by breath gas exchange data averaged over 15 seconds, respiratory exchange ratio (RER) \> 1.10, achieve \> 85% age predicated heart rate maximum (HRmax) and a RPE \> 17 on the 6-20 Borg scale. VO2 at the ventilatory anaerobic threshold (VAT) was defined using the V slope method and verified using ventilatory equivalents. Peak power output (PPO) (watts) and HRmax were defined as the highest value achieved during the CPET with maximum oxygen and heart rate (VO2 /HR) determined by the ratio of VO2max and HRmax. Training Interventions The HIIT group were asked to perform ten one-minute HIIT intervals, each followed by one minute of active recovery (AR) (total exercise time 20 minutes). Resulting from the CPET, HIIT was set at above 85% HRmax with a specific HR designated for this criterion. Active recovery was set at a load corresponding to 25-50 watts. Sessions were performed on a Wattbike trainer (Wattbike Ltd, Nottingham, UK). The CT group completed a practical seven-station mixed modality exercise circuit (cycle ergometer, rower, treadmill, sit to stand/squats, knee to elbow and leg kickback with bicep curl) at an intensity of 60-80% HRmax (calculated from CPET). No resistance equipment was involved, only body weight. Participants initially performed 20 minutes of CT with duration increased by five minutes per week until the desired 40 minutes. Each station was occupied for three to six minutes depending on session duration, moving from one station to the next with minimal rest. During both interventions, HR was measured in last 5 seconds of each station/interval using a FT1 polar heart rate monitor (Polar Electro, Finland) with each CT session timed using a stop watch (Axprod S.L, Guipuzcoa, Spain). Intensity for both interventions was adjusted throughout by the investigator to ensure an appropriate HR range and successful completion of the protocol. Participants were made aware of their HR ranges and verbal encouragement was given by the physiologist to help achieve and maintain these thresholds. Energy expenditure between HIIT and CT was not matched. To assess the validity of the exercise interventions, participant fidelity to the desired exercise intensity was determined using cut points of \>85% HRmax and 60-80% HRmax for HIIT and CT respectively and reported using previous examples. These values were calculated using the participants mean heart rate for each individual interval or station over the 16 sessions and was expressed as a percentage of HRmax as determined by CPET at visit 1. Specific fidelity thresholds were consulted to determine low (\<50%), moderate (50-70%) and high (\>70%) compliance. Adherence was determined as a percentage of completed sessions, with 14 (\> 85%) being the threshold for completion. Statistical Analysis Statistical analysis was conducted using Statistical Package for the Social Sciences (SPSS) version 24 (IBM, New York, USA). An independent t-test was used to identify group differences at baseline. Assumptions of normality were verified using the Shapiro-Wilk test. Skewness and kurtosis of distribution was visually examined. Non-normally distributed data was presented as median and interquartile range (IQR). A two-way (condition x time) repeated measures analysis of variance (ANOVA) was used to compare CRF pre-and post-training. Post-hoc analysis for the main effects and interactions was assessed using a Bonferroni adjustment. Group differences were compared using independent t tests. Variables were displayed as mean with 95% confidence intervals (95% CI) or standard deviation where specified. Partial eta squared effect sizes were also calculated with 0.01, 0.06 and 0.14 representing small, medium and large effect sizes, respectively.

Interventions

OTHERHigh intensity interval training

Participants performed HIIT twice a week for eight weeks. Findings were compared to moderate intensity continuous training which followed the same exercise frequency and duration

The CT group completed a practical seven-station mixed modality exercise circuit (cycle ergometer, rower, treadmill, sit to stand, knee to elbow and leg kickback with bicep curl) at an intensity of 60-80% HRmax twice per week for eight weeks. Participants initially performed 20 minutes of CT with duration gradually increased to the desired 40 minutes as tolerated

Sponsors

University of Hull
CollaboratorOTHER
University of Central Lancashire
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
BASIC_SCIENCE
Masking
NONE

Intervention model description

Participants were randomised to either high or moderate intensity exercise

Eligibility

Sex/Gender
ALL
Age
18 Years to 65 Years
Healthy volunteers
Yes

Inclusion criteria

* Participants reported no medical history of cardiometabolic or limiting respiratory disease, were non-smokers, had a body mass index \<30 kg.m-2, classified as recreationally active

Exclusion criteria

* Cardiometabolic disease, high activity levels, Unable to tolerate the exercise intervention

Design outcomes

Primary

MeasureTime frameDescription
Maximal Oxygen Consumption (ml.Kg-1.Min-1)Baseline and 8 weeksMaximal oxygen consumption (ml.kg-1.min-1), as determined during a cardiopulmonary exercise test (CPET) represents the upper limit of aerobic fitness in humans. A low VO2max is associated with a greater risk of premature all-cause and cardiovascular mortality, independent of traditional risk factors and physical activity status. Conversely, increasing VO2max through exercise training may improve cardiometabolic health, quality of life and increase life-expectancy

Secondary

MeasureTime frameDescription
Oxygen Consumption at the Ventilatory Anaerobic ThresholdBaseline and 8 weeksOxygen consumption at the Ventilatory Anaerobic Threshold ml/kg/min. This measure will assess if individuals can exercise at higher intensities before lactate accumulation, thus becoming 'physiologically efficient

Other

MeasureTime frameDescription
Intervention Fidelity - Participants That Complied With the Exercise Protocols8 weeksTo assess if the interventions were delivered as intended, percentage of participants that complied with the exercise protocols
The Percentage of Individuals That Responsed to the Intervention8 weeksIf participants had a postive increased in maximal oxygen consumption following the two interventions

Countries

United Kingdom

Participant flow

Participants by arm

ArmCount
High Intensity Interval Training
Perform High intensity interval training twice per week for 8 weeks
21
Circuit Training
Perform Circuit training twice per week for 8 weeks
21
Total42

Withdrawals & dropouts

PeriodReasonFG000FG001
Overall StudyLack of Efficacy12

Baseline characteristics

CharacteristicHigh Intensity Interval TrainingCircuit TrainingTotal
Age, Categorical
<=18 years
0 Participants0 Participants0 Participants
Age, Categorical
>=65 years
0 Participants0 Participants0 Participants
Age, Categorical
Between 18 and 65 years
21 Participants21 Participants42 Participants
Age, Continuous42.5 years
STANDARD_DEVIATION 12.3
41.2 years
STANDARD_DEVIATION 12.9
41.9 years
STANDARD_DEVIATION 12.6
Body mass index24.4 kg.m-2
STANDARD_DEVIATION 2.3
25.9 kg.m-2
STANDARD_DEVIATION 2.7
25.2 kg.m-2
STANDARD_DEVIATION 2.5
Diastolic blood pressure75 mmHg
STANDARD_DEVIATION 11
79 mmHg
STANDARD_DEVIATION 9
77 mmHg
STANDARD_DEVIATION 10
Heart rate maximum174 bpm
STANDARD_DEVIATION 12
174 bpm
STANDARD_DEVIATION 14
174 bpm
STANDARD_DEVIATION 13
Maximum oxygen consumption/heart rate12.8 ml.beat-1
STANDARD_DEVIATION 3.7
13.9 ml.beat-1
STANDARD_DEVIATION 3.9
13.6 ml.beat-1
STANDARD_DEVIATION 3.8
Peak power output191.9 watts
STANDARD_DEVIATION 43.7
209.8 watts
STANDARD_DEVIATION 55.2
200.9 watts
STANDARD_DEVIATION 49.5
Race (NIH/OMB)
American Indian or Alaska Native
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Asian
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Black or African American
0 Participants0 Participants0 Participants
Race (NIH/OMB)
More than one race
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Unknown or Not Reported
21 Participants21 Participants42 Participants
Race (NIH/OMB)
White
0 Participants0 Participants0 Participants
Region of Enrollment
United Kingdom
20 Participants19 Participants39 Participants
Respiratory exchange ratio at VO2max1.30 unitless
STANDARD_DEVIATION 0.12
1.31 unitless
STANDARD_DEVIATION 0.12
1.31 unitless
STANDARD_DEVIATION 0.12
Resting heart rate68 bpm
STANDARD_DEVIATION 12
67 bpm
STANDARD_DEVIATION 10
68 bpm
STANDARD_DEVIATION 11
Sex: Female, Male
Female
10 Participants9 Participants19 Participants
Sex: Female, Male
Male
11 Participants12 Participants23 Participants
Systolic blood pressure122 mmHg
STANDARD_DEVIATION 14
126 mmHg
STANDARD_DEVIATION 11
124 mmHg
STANDARD_DEVIATION 12

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
0 / 200 / 19
other
Total, other adverse events
0 / 200 / 19
serious
Total, serious adverse events
0 / 200 / 19

Outcome results

Primary

Maximal Oxygen Consumption (ml.Kg-1.Min-1)

Maximal oxygen consumption (ml.kg-1.min-1), as determined during a cardiopulmonary exercise test (CPET) represents the upper limit of aerobic fitness in humans. A low VO2max is associated with a greater risk of premature all-cause and cardiovascular mortality, independent of traditional risk factors and physical activity status. Conversely, increasing VO2max through exercise training may improve cardiometabolic health, quality of life and increase life-expectancy

Time frame: Baseline and 8 weeks

ArmMeasureGroupValue (MEAN)Dispersion
High Intensity Interval TrainingMaximal Oxygen Consumption (ml.Kg-1.Min-1)Pre Intervention31.5 ml/kg/minStandard Deviation 7.1
High Intensity Interval TrainingMaximal Oxygen Consumption (ml.Kg-1.Min-1)Post Intervention35.4 ml/kg/minStandard Deviation 7.3
Circuit TrainingMaximal Oxygen Consumption (ml.Kg-1.Min-1)Pre Intervention31.4 ml/kg/minStandard Deviation 6.8
Circuit TrainingMaximal Oxygen Consumption (ml.Kg-1.Min-1)Post Intervention32.4 ml/kg/minStandard Deviation 6.2
Comparison: A sample size of 38 using G\*Power 3.1 software was calculated based on previously published data in which the mean difference between HIIT and moderate intensity continuous training (MICT) was 3.2 ml.kg-1.min-1 with a pooled standard deviation of 3 ml.kg-1.min-1. Statistical significance was set at = 0.05 and power set to 0.95. To allow for 10% attrition 42 individuals were recruited to the studyp-value: <0.01ANOVA
Secondary

Oxygen Consumption at the Ventilatory Anaerobic Threshold

Oxygen consumption at the Ventilatory Anaerobic Threshold ml/kg/min. This measure will assess if individuals can exercise at higher intensities before lactate accumulation, thus becoming 'physiologically efficient

Time frame: Baseline and 8 weeks

ArmMeasureGroupValue (MEAN)Dispersion
High Intensity Interval TrainingOxygen Consumption at the Ventilatory Anaerobic ThresholdPre Intervention15.5 ml/kg/minStandard Deviation 2.7
High Intensity Interval TrainingOxygen Consumption at the Ventilatory Anaerobic ThresholdPost Intervention17.9 ml/kg/minStandard Deviation 2.5
Circuit TrainingOxygen Consumption at the Ventilatory Anaerobic ThresholdPre Intervention15.6 ml/kg/minStandard Deviation 3
Circuit TrainingOxygen Consumption at the Ventilatory Anaerobic ThresholdPost Intervention16.2 ml/kg/minStandard Deviation 3.1
p-value: <0.01ANOVA
Other Pre-specified

Intervention Fidelity - Participants That Complied With the Exercise Protocols

To assess if the interventions were delivered as intended, percentage of participants that complied with the exercise protocols

Time frame: 8 weeks

Population: To assess the validity of the exercise interventions, participant fidelity to the desired exercise intensity was determined using cut points using specific cut points. Fidelity was measured over the course of the 16 sessions.

ArmMeasureValue (MEDIAN)
High Intensity Interval TrainingIntervention Fidelity - Participants That Complied With the Exercise Protocols90 Percentage
Circuit TrainingIntervention Fidelity - Participants That Complied With the Exercise Protocols86 Percentage
Other Pre-specified

The Percentage of Individuals That Responsed to the Intervention

If participants had a postive increased in maximal oxygen consumption following the two interventions

Time frame: 8 weeks

Population: A percentage of participants that increased maximal oxygen consumption

ArmMeasureValue (NUMBER)
High Intensity Interval TrainingThe Percentage of Individuals That Responsed to the Intervention100 Percentage
Circuit TrainingThe Percentage of Individuals That Responsed to the Intervention78 Percentage

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026