Skip to content

Myelin Imaging Changes In Patients With Neurosurgical Diseases

A Pilot, Prospective Study of Myelin Imaging Changes in Patients With Neurosurgical Diseases

Status
Terminated
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03698838
Acronym
McDESPOT
Enrollment
20
Registered
2018-10-09
Start date
2019-02-12
Completion date
2020-07-15
Last updated
2020-09-02

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Craniosynostoses, Epilepsy, Hydrocephalus in Children, Traumatic Brain Injury

Brief summary

Investigate myelin alterations in patients with neurosurgical diseases

Detailed description

While a number of advanced imaging techniques, notably magnetization transfer, diffusion tensor and quantitative T1 and T2 imaging (MTI, DTI, qT1 and qT2, respectively), have been used previously to study white matter in neurosurgical diseases, these methods provide only indirect, non-specific information related to myelin content. For example, these modalities can tell when there is swelling that is affecting the movement of water, which may be indicative of a process that would affect myelin, but they cannot tell us specific information about the amount of myelin surrounding a nerve. The investigators propose using a MRI sequence, mcDESPOT (multicomponent driven equilibrium potential of T1 and T2) that utilizes a computer model that takes T1 and T2 sequences and derives a quantitative value for the myelin content in the myelin sheath. In the present program, the investigators propose adding the mcDESPOT sequence to the MRI scanner in accordance with the MRI manufacturer's technical requirements. When this sequence is added, the normal sequences are done first and mcDESPOT is done last. Although the sequences obtained for mcDESPOT are sequences used in clinical practice, the flip-angles are changed so that they cannot be read like a traditional image. Rather, the data have to be post-processed by a computer in order to be able to derive myelin information. McDESPOT is a 10 minute sequence that can be added to any MRI scanner. It is a obtained from standard T1 and T2 sequences.

Interventions

DEVICEMcDESPOT

MRI sequence, mcDESPOT (multicomponent driven equilibrium potential of T1 and T2) that utilizes a computer model that takes T1 and T2 sequences and derives a quantitative value for the myelin content in the myelin sheath

Sponsors

Memorial Healthcare System
Lead SponsorOTHER

Study design

Observational model
OTHER
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
No minimum to 19 Years
Healthy volunteers
No

Inclusion criteria

1. Patient age range: 0-19 2. Patients who have an MRI ordered clinically and have one of the following conditions: epilepsy, hydrocephalus, craniosynostosis or mild traumatic brain injury. Epilepsy, hydrocephalus and craniosynostosis patients will be both newly diagnosed and chronic. MTBI patients will be acute and chronic and defined as a glascow coma score (GCS) of 13-15. 3. Patients or their proxy should be capable of giving informed consent

Exclusion criteria

1\. Unable to tolerate an extra 10 minutes of MRI scan

Design outcomes

Primary

MeasureTime frameDescription
Myelin Alterations Read on MRI sequence10 minutesInvestigate myelin alterations in patients with neurosurgical diseases with McDESPOT sequence on MRI scanner for T1 and T 2 scans.

Countries

United States

Outcome results

None listed