Skip to content

Apogee, A HeartWare HVAD Destination Product Surveillance Registry (PSR) Platform

Apogee, A HeartWare HVAD Destination Product Surveillance Registry (PSR) Platform

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03697980
Enrollment
136
Registered
2018-10-05
Start date
2019-01-17
Completion date
2022-02-10
Last updated
2023-12-04

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Chronic Heart Failure

Brief summary

Medtronic is sponsoring the Apogee study to further enhance scientific understanding of the implant procedure, optimized blood pressure management, and anticoagulation/ antiplatelet therapy in patients receiving a Medtronic HeartWare™ Ventricular Assist Device (HVAD™) for destination therapy. The Apogee study is conducted within Medtronic's Product Surveillance Platform.

Detailed description

The Apogee study is a prospective, observational, post-market, on-label, multi-site study in Destination Therapy patients. Patients participating in the Medtronic Destination Therapy (DT) Post Approval Study (PAS) (NCT03681210) are eligible for participation in Apogee. Patients enrolled in Apogee will be followed under the Apogee study for one-year post-implant. After participation in Apogee ends, patients will remain enrolled in DT PAS and will continue to be followed as outlined in the DT PAS protocol. The total estimated study duration is 33 months.

Interventions

The HVAD is an implantable centrifugal rotary blood pump that is implanted in the pericardial space and is designed to provide up to 10 L/min of blood flow from the left ventricular to the aorta. The HVAD System is comprised of three major components: the HVAD (pump) with inflow and outflow conduits, a Controller (microprocessor unit that controls the operation of the HVAD), and power sources (AC and DC power adapters that provide power to the Controller and implanted HVAD).

Sponsors

Medtronic Cardiac Rhythm and Heart Failure
Lead SponsorINDUSTRY

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Subjects consented to participate in DT PAS are eligible for participation in Apogee.

Exclusion criteria

* There are no

Design outcomes

Primary

MeasureTime frameDescription
Rate of Major Adverse EventsImplant to 12 monthsFreedom from event is the probability (expressed as a percent of 100) the participant did not have a major adverse event during 12 months post implant via the Kaplan-Meier method. Participants that did not have a major adverse event were censored at the time of last follow-up in Apogee or their end of study at 12 months post implant, whichever occurred first. Major adverse events are defined to be occurrence of infection, bleeding, device malfunction, CT confirmed stroke, or death. Infection, bleeding, device malfunction and CT confirmed stroke were categorized via Intermacs Version 5.0. Events occurring during the implant procedure were excluded.

Countries

United States

Participant flow

Pre-assignment details

Participants were considered enrolled upon signing informed consent. 12 enrolled participants weren't implanted due to death or screen failure prior to implant.

Participants by arm

ArmCount
HVAD
HeartWare Ventricular Assist Device: The HVAD is an implantable centrifugal rotary blood pump that is implanted in the pericardial space and is designed to provide up to 10 L/min of blood flow from the left ventricular to the aorta. The HVAD System is comprised of three major components: the HVAD (pump) with inflow and outflow conduits, a Controller (microprocessor unit that controls the operation of the HVAD), and power sources (AC and DC power adapters that provide power to the Controller and implanted HVAD).
124
Total124

Baseline characteristics

CharacteristicHVAD
Age, Continuous57.7 years
STANDARD_DEVIATION 12.3
Device Strategy at Time of Implant
Bridge to Transplant
0 Participants
Device Strategy at Time of Implant
Destination Therapy
124 Participants
Ethnicity (NIH/OMB)
Hispanic or Latino
14 Participants
Ethnicity (NIH/OMB)
Not Hispanic or Latino
103 Participants
Ethnicity (NIH/OMB)
Unknown or Not Reported
7 Participants
Race/Ethnicity, Customized
Race
American Indian or Alaska Native
1 Participants
Race/Ethnicity, Customized
Race
Asian
3 Participants
Race/Ethnicity, Customized
Race
Black or African American
36 Participants
Race/Ethnicity, Customized
Race
Native Hawaiian or Other Pacific Islander
2 Participants
Race/Ethnicity, Customized
Race
Other
9 Participants
Race/Ethnicity, Customized
Race
White
73 Participants
Region of Enrollment
United States
124 participants
Sex: Female, Male
Female
27 Participants
Sex: Female, Male
Male
97 Participants

Adverse events

Event typeEG000
affected / at risk
deaths
Total, all-cause mortality
27 / 136
other
Total, other adverse events
24 / 124
serious
Total, serious adverse events
109 / 124

Outcome results

Primary

Rate of Major Adverse Events

Freedom from event is the probability (expressed as a percent of 100) the participant did not have a major adverse event during 12 months post implant via the Kaplan-Meier method. Participants that did not have a major adverse event were censored at the time of last follow-up in Apogee or their end of study at 12 months post implant, whichever occurred first. Major adverse events are defined to be occurrence of infection, bleeding, device malfunction, CT confirmed stroke, or death. Infection, bleeding, device malfunction and CT confirmed stroke were categorized via Intermacs Version 5.0. Events occurring during the implant procedure were excluded.

Time frame: Implant to 12 months

Population: All implanted participants are included.

ArmMeasureValue (NUMBER)
HVADRate of Major Adverse Events18.2 % probability of freedom from major AE

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026