Skip to content

Time Course Evolution of Cardiac Output

Time Course Evolution of Cardiac Output in Critically Ill Patients After a Fluid Expansion

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03694717
Acronym
TCCO
Enrollment
58
Registered
2018-10-03
Start date
2016-04-15
Completion date
2018-05-31
Last updated
2018-10-04

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Acute Circulatory Failure

Keywords

shock, fluid expansion, fluid responsiveness

Brief summary

Fluid expansion is the first therapeutic option in patients presenting acute circulatory failure but the duration of its hemodynamic effects (persistency and time of maximal increase in cardiac output) is unknown. This study is seeking to describe in critically ill patients, the time course evolution of cardiac output over a 2-hours period after a fluid expansion. The objectives are: 1. to identify patterns of fluid responsiveness 2. to determine the time when the maximal increase in cardiac output occurs during and a after fluid expansion 3. to compare patients' characteristics between patterns Patients with acute circulatory failure will be recruited as soon as a fluid expansion will be decided by the physician in charge and the effects of fluid expansion on hemodynamic indices (cardiac output, arterial pressure) will be continuously recorded through a transpulmonary thermodilution device over a 2-hours period. No changes in ventilatory settings nor vasopressors or sedatives will be allowed during the study. Patients will be categorized into patterns according to the changes in cardiac output after fluid expansion and their characteristics will be compared.

Detailed description

The study will be conducted in four medico-surgical ICUs in France between April 2016 and April 2018. Since fluid challenge and invasive monitoring by thermodilution device is standard of care for septic shock management, the institutional review board waived patient consent. All patients and/or their next of kind will receive written information. Eligible patients will have to present an acute circulatory failure for whom the physician in charge will decide to start a fluid expansion. Hemodynamic variables will be obtained through transpulmonary thermodilution and pulse contour analysis (PICCO2 device, Pulsion Germany). Fluid expansion will consist in the infusion of 500 ml of saline through a central venous catheter in a standardized 10-minutes period. The duration of infusion will be controlled by an airbag pressurized at 300 mmHg. Fluid responsiveness will be defined by an increase in cardiac output over 15-per-cent from baseline (before fluid expansion). Study design: At time of decision to make the fluid expansion, a calibration of the PICCO2 device will be performed and a first set of hemodynamic measurements will be collected (cardiac output, cardiac function index, extravascular lung water, permeability vascular pulmonary index, global end diastolic volume, arterial pressure, heart rate). Then, fluid expansion will be administrated in less than 10 minutes. From the start of fluid expansion to the end of the two-hours period ot time, pulse contour cardiac output and arterial pressure will be continuously recorded. During the whole two hours period, no change in vasopressor dosage nor mechanical ventilation settings will be allowed. In case of hemodynamic instability, defined by a mean arterial pressure under 65mmHg, a new fluid expansion could be realized. In this last case, the protocol will start again from the beginning.

Interventions

The fluid expansion will consist in a less than 10 min infusion of 500 milliliters of saline through a central venous catheter (jugular). The duration of infusion will be controlled by an airbag pressurized at 300 mmHg.

Sponsors

Association pour le Développement et l'Organisation de la Recherche en Pneumologie et sur le Sommeil
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 99 Years
Healthy volunteers
No

Inclusion criteria

* acute circulatory failure (infusion of norepinephrine) * invasive mechanical ventilation through an endotracheal tube * decision of fluid expansion Non inclusion Criteria: * extracorporeal membranous oxygenation (ECMO) * active bleeding * continuous renal replacement therapy with weight loss * administration of diuretics within the past six hours * decision of therapeutic limitation, * age under eighteen years

Exclusion criteria

* hemodynamic instability after fluid expansion (mean arterial pressure \< 65mmHg)

Design outcomes

Primary

MeasureTime frameDescription
Change in cardiac output during fluid expansion10 minutesDifference between maximal cardiac output during fluid expansion and baseline

Secondary

MeasureTime frameDescription
Change in cardiac output after fluid expansion2 hoursChange in cardiac output after fluid expansion

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026