Skip to content

Study of Transcatheter Tricuspid Annular Repair

Study of Transcatheter Tricuspid Annular Repair

Status
Recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03692598
Acronym
STTAR
Enrollment
60
Registered
2018-10-02
Start date
2016-12-31
Completion date
2026-12-31
Last updated
2024-10-23

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Tricuspid Regurgitation

Brief summary

The purpose of the study is to evaluate the safety and performance of the MIA Minimally Invasive Annuloplasty Device in patients with chronic functional tricuspid regurgitation.

Detailed description

The purpose of the study is to evaluate the safety and performance of the MIA Minimally Invasive Annuloplasty Device in patients with chronic functional tricuspid regurgitation. The study is a prospective, multi-center safety and performance study. Enrolled subjects will be assessed for clinical follow-up at 1 month, 6 months, and 1 year post implant procedure.

Interventions

DEVICEMIA, Minimally Invasive Annuloplasty Device - Surgical

Eligible patients will receive implantation of MIA implants deployed using the MIA, Minimally Invasive Annuloplasty Device from an open surgical approach

DEVICEMIA, Minimally Invasive Annuloplasty Device - Percutaneous

Eligible patients will receive implantation of MIA implants deployed using the MIA, Minimally Invasive Annuloplasty Device from a percutaneous approach

Sponsors

Micro Interventional Devices
Lead SponsorINDUSTRY

Study design

Allocation
NON_RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 85 Years
Healthy volunteers
No

Inclusion criteria

1. Chronic functional tricuspid regurgitation (FTR) with a minimum of moderate tricuspid regurgitation (2-4) 2. Age≥18 and ≤85 years old 3. New York Heart Association (NYHA) Class II, III or ambulatory IV 4. Left ventricular ejection fraction (LVEF) ≥30% 5. Undergoing cardiac surgical procedure with the planned use of cardiopulmonary bypass (surgical arm only) 6. Functional tricuspid valve regurgitation pathology with a structurally normal valve; and tricuspid valve annular diameter ≥ 40 mm (or 21 mm/m2) and ≤55 mm (or 29 mm/m2) or 2-4 + FTR 7. Patient provides written Informed Consent before any study-specific tests or procedures are performed 8. Patient is willing and able to comply with all specified study evaluations

Exclusion criteria

1. Pregnant or lactating female 2. Severe uncontrolled hypertension (SBP ≥ 180 mmHg and/or DBP ≥ 110 mmHg) 3. Previous tricuspid valve repair or replacement 4. Myocardial Infarction or known unstable angina within the 30-days prior to the index procedure 5. Any PCI within 30 days prior to the index procedure or planned 3 months post the index procedure 6. Life expectancy of less than 12-months 7. Severe right heart dysfunction 8. Pulmonary hypertension with PA mean 2/3 rd MAP 9. Active systemic infection 10. Pericardial infection 11. Any clinical evidence that the investigator feels would place the patient at increased risk with the deployment of the device 12. Co-morbid conditions that place the subject at an unacceptable surgical risk (e.g. severe chronic obstructive pulmonary disease, hepatic failure, cardiac disease, autoimmune disorders or conditions of severe immunosuppression) 13. Untreated coronary artery disease (CAD) requiring revascularisation unless CABG procedure is concomitant with MIA tricuspid annular repair (surgical arm only) 14. Haemodynamic instability: systolic blood pressure \<90mmHg without reduction of afterload, shock, need for inotropic medication or IABP 15. Active peptic ulcer or gastrointestinal (GI) bleeding in the past 3 months 16. Cerebrovascular event within the past 6 months 17. History of mitral/tricuspid endocarditis within the last 12 months 18. Organic tricuspid disease 19. Contraindication or known allergy to device's components, aspirin, anti-coagulation therapy or contrast media that cannot be adequately premeditated 20. Known alcohol or drug abuser 21. Currently participating in the study of an investigational drug or device

Design outcomes

Primary

MeasureTime frameDescription
Major Adverse Events30 daysThe percentage of participants with Major Adverse Events within 30 days of the procedure: death, Q-wave myocardial infarction, cardiac tamponade, cardiac surgery for failed MIA implantation, or stroke
Reduction in tricuspid regurgitation at 30 days30 daysThe reduction in the degree of tricuspid regurgitation compared to baseline measured post-procedure, at post-operative hospital discharge and at 1 month post-operative. Ability to reduce tricuspid regurgitation by at least 1 degree by means of quantitative echocardiographic parameters

Secondary

MeasureTime frameDescription
Serious Adverse Events (SAEs) and Serious Adverse Device Events (SADE)3 monthsThe percentage of participants with Serious Adverse Events (SAEs) and Serious Adverse Device Events (SADE) within 6 months of the procedure will be compared to the literature.
Reduction in tricuspid regurgitation3 monthsAssessment in the degree of Tricuspid Regurgitation at 3 months compared to baseline Ability to maintain improvement in tricuspid regurgitation with respect to baseline.
Quality of Life Measurement3 monthsChange in quality of life questionnaire (Minnesota Living with Heart Failure Questionnaire) compared to baseline at 6 months

Countries

Denmark, Hungary, Latvia, Lithuania, Poland

Contacts

Primary ContactAngie Swenson
aswenson@microinterventional.com

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026