Skip to content

Stability of Patient-specific Root-analogue Implants and Conventional Root-form Implants for Treating Non-restorable Single-rooted Maxillary Teeth

Stability of Patient-specific Root-analogue Implants and Conventional Root-form Implants for Treating Non-restorable Single-rooted Maxillary Teeth

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03689933
Enrollment
10
Registered
2018-10-01
Start date
2018-11-30
Completion date
2020-01-31
Last updated
2018-10-01

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Conventional Root Form Implant, Implant Stability, Non Restorabl Teeth, Root Analog Implant

Brief summary

its a experimental study comparing between the stability of immediate root fomed implant versus the conventional titanium implant

Detailed description

Patients will be selected from the out-patient clinic according to the inclusion and exclusion criteria, from where the participants will be divided into two equal groups using computer generated random table and the sequence of the random numbers will be only revealed to the Co-supervisor who will report the assigned treatment to the principal investigator. Immediate placement of root analogue titanium dental implants. All patients in the study group will be radiographed using cone beam computed tomography for diagnosis and evaluating the attachment of the tooth and bone level. The tooth indicated for extraction will be extracted atraumatically using periotome, socket preservation using Iodoform packing strips, and then optical scanning of the remaining tooth structure with optical scanner will be made to obtain a 3D virtual model, this model will be modified by addition of macro-retentions strictly to the interdental area to avoid any fracture in thin cortical bone, the cervical portion of implant circumference will be decreased by 0.1 to 0.2 mm to avoid pressure resorption of alveolar crest of bone and addition of prepared crown stump for the future crown to be placed. After all additions and adjustments are being made, an STL (stereolithography) extension file followed by milling of the implant from medically grade titanium will be carried out, followed by sandblasting acid etching. For sterilization, the implant will be washed in a 90% concentration ethanol ultrasonic bath for 10 minutes, followed by packaging and sterilizing in a steam pressure autoclave. At the day of implant placement, removing of suture and the Iodoform gauze followed by flushing of the extraction socket using saline solution and vigorous curettage of the socket. Then implant placement will be made by hand pressure followed by tapping using mallet. Implant stability in both groups will be measured using Periotest device. The measuring procedure will be made immediate postoperative, 3 months and 6 months.

Interventions

DEVICERoot analog implant

a custom made root analogue implant made from milled titanium

Sponsors

Cairo University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
21 Years to 50 Years
Healthy volunteers
Yes

Inclusion criteria

1. Single rooted teeth indicated for extraction and immediate implant placement. 2. The age of candidates ranges from 21 to 50 years.

Exclusion criteria

1. Absence of any disease or systemic complication which might affect osseointegration. 2. The cause of extraction mustn't be due to periodontitis or periapical infection.

Design outcomes

Primary

MeasureTime frameDescription
implant stability6 monthsusing periotest

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026