Clinical Validation of the Molecular-Based GenePOC Carba Assay for the Detection and Differentiation of Carbapenemase Genes in Rectal Swab Samples.

Prospective Study for Clinical Validation of the Molecular-Based GenePOC Carba Assay for the Detection and Differentiation of Carbapenemase Genes of Gram-negative Bacteria (blaIMP, blaKPC, blaNDM, blaOXA-48-like and blaVIM) in Rectal Swab Samples From Patients Suspected of Being Colonized. The Targeted Organisms Are Enterobacteriaceae, Acinetobacter Baumannii, and Pseudomonas Aeruginosa.

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03680898
Enrollment
1200
Registered
2018-09-21
Start date
2019-02-12
Completion date
2023-06-30
Last updated
2021-04-30

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Carbapenem-Resistant Enterobacteriaceae

Keywords

Carbapenem, rectal swab, infectious disease, infection

Brief summary

The primary purpose of this clinical investigation is to establish the performance of the GenePOC Carba assay on the revogene. This will be achieved by comparing the test to a conventional method for detection of Carbapenemase Producing Organisms (CPOs) in rectal swab samples.

Detailed description

The GenePOC Carba assay will be performed using the revogene instrument. The revogene instrument, used in conjunction with appropriate reagents, is capable of automated cell lysis, dilution of nucleic acids from multiple sample types as well as automated amplification and detection of target nucleic acid sequences. The GenePOC Carba assay reagents kits consist of: 1. Sample Buffer Tube (SBT) 2. Disposable Transfer Tool (DTT) 3. Disposable microfluidic cartridges (PIE) The test is performed using the revogene™. The revogene automates sample homogenization, sample dilution, cells lysis, DNA amplification, and detection of the amplified PCR products. User intervention is only required for discharging the patient sample into the Sample Buffer Tube (SBT), transferring the sample into the PIE, and loading/unloading the PIEs into the revogene carousel. A dual swab sample is collected when ICF is signed by patient. One of the swab is transferred into the SBT and vortexed. Sample is then transferred to the GenePOC Carba PIE. The PIE is then automatically processed by the revogene. On completion of a run, the user removes the processed PIEs from the instrument and discards them according to local biological waste management procedures. One revogene will be allocated per site. The purpose of this clinical trial is to enroll sufficient patients from up to 14 Clinical Centers to meet regulatory requirements, based on the Reference Method final results.

Interventions

Patient will provide a rectal swab by following hospital-provided instructions.

Sponsors

Meridian Bioscience, Inc.
Lead SponsorINDUSTRY

Study design

Allocation
NON_RANDOMIZED
Intervention model
PARALLEL
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
2 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Samples from patients who were previously diagnosed to be infected with CPOs, or were identified per hospital policies as being suspected or are at risk for CPO infection; * Patient that signed the approved Informed Consent Form (if applicable) * Patient older than 2 years of age (\>24.0 months) * Only one (1) compliant sample per patient is allowed

Exclusion criteria

* Patient/sample not meeting inclusion criteria above

Design outcomes

Primary

MeasureTime frameDescription
Performance characteristics : Clinical sensitivity (true positive rate) in comparison to the Reference Methodup to 3 monthsTo establish the performance characteristics of the GenePOC Carba assay for its use in determining the presence of CPO/CPE in rectal swab samples obtained from patients suspected of being infected, or considered at risk. Sensitivity will be estimated as the proportion of positives that are correctly identified by the Carba assay when compared to the Reference Method.
Performance characteristics : clinical specificity (true negative rate) in comparison to the Reference Methodup to 3 monthsTo establish the performance characteristics of the GenePOC Carba assay for its use in determining the presence of CPO/CPE in rectal swab samples obtained from patients suspected of being infected, or considered at risk. Sensitivity will be estimated as the proportion of positives that are correctly identified by the Carba assay when compared to the Reference Method.

Countries

Canada, United States

Outcome results

None listed