Skip to content

Total Hip Arthoplastry Revision by Dual-mobility Acetabular Cup Cemented in a Metal Reinforcement

Total Hip Arthoplastry Revision by Dual-mobility Acetabular Cup Cemented in a Metal Reinforcement: A 62 Case Series at a Minimum 5 Years Follow-up

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03680443
Acronym
PTH
Enrollment
62
Registered
2018-09-21
Start date
2013-01-01
Completion date
2017-04-26
Last updated
2026-06-16

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Arthroplasty Complications, Aseptic Loosening

Keywords

revision, reinforcement

Brief summary

Total hip arthroplasty (THA) requires bone reconstruction in case of severe acetabular injury, with risk of dislocation, especially postoperatively. Dual-mobility cups have proved effective in preventing dislocation in THA revision for instability, but their behavior when cemented in a metal reinforcement has been little studied. The present study assessed results for a dual-mobility cup cemented in a metal reinforcement, in terms of aseptic loosening and postoperative instability. A single-center continuous series of 62 patients receiving such an assembly in THA revision was assessed retrospectively at a minimum 5 years' follow-up.

Detailed description

Total hip arthroplasty (THA) requires bone reconstruction in case of severe acetabular injury, with risk of dislocation, especially postoperatively. Dual-mobility cups have proved effective in preventing dislocation in THA revision for instability, but their behavior when cemented in a metal reinforcement has been little studied. The present study assessed results for a dual-mobility cup cemented in a metal reinforcement, in terms of aseptic loosening and postoperative instability. A single-center continuous series of 62 patients receiving such an assembly in THA revision was assessed retrospectively at a minimum 5 years' follow-up. Failure due to aseptic loosening or instability and implant survival at last follow-up were analyzed.

Interventions

OTHERassembly in THA revision

A single-center continuous series of 62 patients receiving such an assembly in THA revision was assessed retrospectively at a minimum 5 years' follow-up. Failure due to aseptic loosening or instability and implant survival at last follow-up were analyzed.

Sponsors

Centre Hospitalier Universitaire, Amiens
Lead SponsorOTHER

Study design

Observational model
CASE_ONLY
Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
19 Years to 94 Years
Healthy volunteers
No

Inclusion criteria

* patients between 19 and 84 years * patients receiving such an assembly in THA revision

Exclusion criteria

* \<19years * \> 94 years

Design outcomes

Primary

MeasureTime frameDescription
dual-mobility cup cemented (effectiveness in terms of aseptic loosening)5 yearsThe objective of the present study is to evaluate the most effective type of assembly , dual-mobility cup cemented in a metal reinforcement, in terms of aseptic loosening in the prevention of dislocation during the revision of the total hip arthroplasty (THA)

Countries

France

Contacts

PRINCIPAL_INVESTIGATORPatrice MERTL, MD, PhD

CHU AMIENS

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Jun 17, 2026