Skip to content

Retention of Computer Aided Design and Computer Aided Manufacturing Titanium Versus Co/Cr Single Dentures.

Retention of Computer Aided Design and Computer Aided Manufacturing Titanium Versus Cobalt/Chromium Maxillary Single Denture Bases: A Randomized Clinical Trial.

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03675594
Enrollment
12
Registered
2018-09-18
Start date
2018-12-01
Completion date
2019-09-30
Last updated
2018-09-19

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Edentulous Mouth

Keywords

Dislodgement force, Digital denture, CAD/CAM metallic dentures

Brief summary

* Steps in short: Undergoing the conventional steps of maxillary single denture construction till the step of framework construction that will be designed and constructed using CAD/CAM after optical scanning of the master cast ( 2 frameworks to cover the palate and crest of the ridge : one made of titanium and the other made of cobalt/chromium) then conventional steps will be undergone including bite, Try-in and delivery ending by measuring the denture retention. * Number of visits & follow up period : Visits: will be 5-6 visits for each patient. Follow up period: 6.5 months (immediately post-insertion then after 1 week then after 3 months for the first type then 2 weeks washout period and the same for the second type)

Detailed description

The study will be carried out in the department of prosthodontics-cairo university. Patients will be selected from the out-patient clinic according to the inclusion criteria, The primary impression will be made with alginate (cavex-normal set) and will be border-molded to get the acceptable extension and border thickness, a tray will be prepared with self-activated acrylic resin over the study cast. A secondary impression will be made with heavy putty consistency as a border molding material and the final impression will be made with light rubber base (3M) impression material, Then Pouring of the final impressions with type 4 Hydrocal dental stone (Hydrocal Dental stone, Bayer, and Germany). Master casts will be optically scanned using 3 shape optical scanner. Duplication of master casts will be done using silicone duplicating material. Titanium and cobalt/chromium metallic bases will be milled using 3shape milling machine to cover the palate with mesh extension over the ridge. They will be tried intra-orally regarding sitting and stability. Occlusal rim will be set on titanium metallic base then face bow record will be recorded then mounting the maxillary master cast. Centric relation will be registered then mounting of the mandibular cast will be done. The same will be done for the duplicate cast with the Cobalt/Chromium metallic base. Then Setting of the anatomical teeth for both master casts then try-in stage will be checked intra-orally then packing of cast and duplicate cast with conventional heat cured acrylic resin (Dentsply, Dentsply limited, Weybridge, Surrey. England) after flasking each denture will be finished. The dentures will be delivered, then the assessment will be immediately and after 1 week then after 3 months that a hook screw with its nut (Digital force gauge instrument, model 475044) will be secured in the polished mid-palatal surface of the upper denture using metallic adhesive to record the amount of the force required for dislodgment. The pull end of the digital force gauge device will be connected to the hook positioned at maxillary dentures for one type of the two dentures and will be pulled vertically until denture dislodgement occurred, then the patient will take off his first type of denture for 2 weeks as a washout period then the second type of denture will be delivered and the same assessment will be done.

Interventions

DEVICECAD/CAM titanium denture base

metallic denture base made of titanium

DEVICECAD/CAM cobalt/chromium denture bases

metallic denture bases made of cobalt/chromium

Sponsors

Cairo University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
OTHER
Masking
DOUBLE (Subject, Outcomes Assessor)

Masking description

the participants will not be told which type they received till obtaining the final results of both types.Outcomes will be collected only by the supervisor.

Eligibility

Sex/Gender
ALL
Age
40 Years to 55 Years
Healthy volunteers
Yes

Inclusion criteria

* Completely edentulous maxillary arch and fully dentate mandibular arch with adequate interarch space. * The edentulous ridges should be covered by firm healthy mucosa. * Angle class I maxillomandibular relationship * Healthy and co-operative patients.

Exclusion criteria

* Patients with bad habits as severe clenching or bruxism, drug or alcohol addiction, moderate or heavy smoking (greater than I 0 cigarettes/day). * Previous history of radiotherapy or chemotherapy. * Any skeletal problem dictates surgical intervention.

Design outcomes

Primary

MeasureTime frameDescription
Retention of single denture6.5 monthsthe dislodgement force of the denture will be assessed

Countries

Egypt

Contacts

Primary ContactAmal el rekaby, professor
prosthetic@dentistry.cu.edu.eg0122258794
Backup Contactahmed saad, lecturer
ahmed_saad@dentistry.cu.edu.eg0118976584

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026