Skip to content

Endoscopic Fundoplication With MUSE System

Clinical Application of MUSE System for Ultrasound-guided Endoscopic Fundoplication for Gastro-esophageal Reflux Disease Patients

Status
Recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03669874
Enrollment
80
Registered
2018-09-13
Start date
2015-09-16
Completion date
2026-09-30
Last updated
2020-12-11

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Endoscopic Fundoplication, Gastro-esophageal Reflux

Brief summary

This is a spontaneous, prospective, monocentric, observational, cohort study, with the aim of evaluating the effect of ultrasound-guided endoscopic fundoplication using the Medigus Ultrasonic Surgical Endostapler (MUSESystem; MediGus, Ltd. Israel) in patients with esophageal or extra-esophageal gastro-oesophageal reflux disease (GERD)-related symptoms. The end of the study will be at the end of the 6-year follow-up of the last patient enrolled. The study proposes the following objectives: * Primary objective: to evaluate the efficacy of endoscopic fundoplication with MUSE for the treatment of GERD, through clinical experience, in terms of: * effect on GERD-Health Related Quality of Life (HRQL) and Reflux Symptom Index (RSI) questionnaire scores * effect on the use and dosage of proton pump inhibitors (PPI) * feasibility and safety of the endoluminal fundoplication procedure * Secondary objective: to characterize the treated patient population (demographic and objective data) and to identify the successful predictors of the procedure. The study design includes the following phases: \*Preliminary patient evaluation and verification of inclusion criteria through: Upper GI endoscopy Esophageal high-resolution manometry 24-hours esophageal pH-impedance OFF PPI PPI use GERD-HRQL and RSI questionnaires scores OFF PPI * 6-month follow-up: Upper GI endoscopy Esophageal high-resolution manometry 24-hours esophageal pH-impedance OFF PPI PPI use GERD-HRQL and RSI questionnaires scores OFF PPI * 12-months follow-up: Upper GI endoscopy 24-hours esophageal pH-impedance OFF PPI PPI use GERD-HRQL and RSI questionnaires scores OFF PPI * Yearly clinical follow-up (up to 6 years): PPI use GERD-HRQL and RSI questionnaires scores OFF PPI

Interventions

DEVICEEndoscopic fundoplication

Endoscopic fundoplication is a less invasive alternative to the traditional surgical fundoplication. The MUSE device is similar to an endoscope, so the whole procedure can be done by a single operator. The device is composed of a shaft with a distal rigid part which is placed in the esophagus 3 cm proximal to the esophago-gastric junction containing a cartridge holding five B-shaped titanium surgical Staples and a tip which is retroflexed and contains an ultrasonic transducer which defines the correct tissue thickness for stapling the fundus against the esophagus. The device must be extracted to be reloaded with 5 more staples at a time for creation of a 180° anterior fundoplication.

Sponsors

IRCCS San Raffaele
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 70 Years

Inclusion criteria

* Chronic (\> 6 months) GERD-related esophageal or extra-esophageal symptoms * Endoscopic or pH-impedance evidence of GERD (esophagitis, Barrett's esophagus, NERD, hypersensitive esophagus) * Indication to surgical fundoplication * Patients available for a long-term follow-up

Exclusion criteria

* Hiatal hernia ≥ 3 cm * Major esophageal motility disorder * Esophageal stenosis * Malignant neoplasia (except minor superficial skin neoplasm) * Portal hypertension, bleeding disorders so to controindicate surgery, esophageal varices, stenosis or diverticula * Previous cardiac, thoracic or upper GI surgery * BMI \>40 * Pregnancy or breast feeding

Design outcomes

Primary

MeasureTime frameDescription
To evaluate clinical efficacy of endoscopic fundoplication with MUSE as assessed by change in GERD-HRQL (Gastro-esophageal Reflux Disease-Health Related quality of life) questionnaire scorechange from baseline GERD-HRQL at 6 monthsGERD-HRQL is a validate questionnaire to evaluate GERD-related esophageal symptoms. The scale range is (0-50); the higher values represents worse outcomes.
To evaluate clinical efficacy of endoscopic fundoplication with MUSE as assessed by change in RSI (Reflux Symptom Index) questionnaire scorechange from baseline RSI at 6 monthsRSI is a validate questionnaire to evaluate GERD-related extra- esophageal symptoms. The scale range is (0-45); the higher values represents worse outcomes.
To evaluate clinical efficacy of endoscopic fundoplication with MUSE as assessed by changes in proton pump inhibitors (PPI) consumptionchange from baseline PPI consumption at 6 monthsGastric antisecretive therapy with proton pump inhibitors (PPI) is the gold standard for the treatment of GERD. This therapy is a chronic therapy with possible side effects. The endoscopic procedure under study aims to halved or discontinue the medical therapy

Secondary

MeasureTime frameDescription
To identify endoscopic factors predicting positive outcomes: changes in esophagitis' gradechange from baseline esophagitis' grade at 6 monthsEndoscopic fundoplication with MUSE modifies the anatomy of the esophago-gastric junction to reduce the reflux of gastric contents into the esophagus. The presence of esophagitis and its grade, as defined by the Los Angeles classification, is a parameter of procedure's efficacy. The esophagitis grade range from A to D; the higher grades represents worse outcomes.
To identify pathophysiological factors predicting positive outcomes: changes in DeMeester scorechange from baseline DeMeester score at 6 monthsparameter detected by 24hours esophagel pH-metry. pH-metric and impedance parameters are indicators of procedure effectiveness as able to quantify the presence of gastro-esophageal reflux. DeMeester score is a composite score which examined six variables (number of reflux episodes, number of episodes longer than 5 minutes, longest reflux duration, total percentage of monitoring time with pH below 4, and the percentage of time with pH below 4 in an upright position and supine position). A score of \>14.72 shows a pathological reflux. Higher values represent worse outcomes.
To identify pathophysiological factors predicting positive outcomes: changes in AET (Acid Exposure Time)change from baseline AET at 6 monthsparameter detected by 24hours esophagel pH-metry. pH-metric and impedance parameters are indicators of procedure effectiveness as able to quantify the presence of gastro-esophageal reflux.
To identify pathophysiological factors predicting positive outcomes: changes in longest reflux episode (min)change from baseline longest reflux episode at 6 monthsparameter detected by 24hours esophagel pH-metry. pH-metric and impedance parameters are indicators of procedure effectiveness as able to quantify the presence of gastro-esophageal reflux.
To identify pathophysiological factors predicting positive outcomes: changes in number of refluxes greater than 5 minuteschange from baseline number of refluxes greater than 5 minutes at 6 monthsparameter detected by 24hours esophagel pH-metry. pH-metric and impedance parameters are indicators of procedure effectiveness as able to quantify the presence of gastro-esophageal reflux.
To identify pathophysiological factors predicting positive outcomes: changes in number of total refluxeschange from baseline number of total refluxes at 6 monthsparameter detected by 24hours esophagel impedance. pH-metric and impedance parameters are indicators of procedure effectiveness as able to quantify the presence of gastro-esophageal reflux.
To identify pathophysiological factors predicting positive outcomes: changes in number of acid refluxeschange from baseline number of acid refluxes at 6 monthsparameter detected by 24hours esophagel impedance. pH-metric and impedance parameters are indicators of procedure effectiveness as able to quantify the presence of gastro-esophageal reflux.
To identify pathophysiological factors predicting positive outcomes: changes in number of weakly acid refluxeschange from baseline number of weakly acid refluxes at 6 monthsparameter detected by 24hours esophagel impedance. pH-metric and impedance parameters are indicators of procedure effectiveness as able to quantify the presence of gastro-esophageal reflux.
To identify pathophysiological factors predicting positive outcomes: changes in number of not acid refluxeschange from baseline number of not acid refluxes at 6 monthsparameter detected by 24hours esophagel impedance. pH-metric and impedance parameters are indicators of procedure effectiveness as able to quantify the presence of gastro-esophageal reflux.
To identify pathophysiological factors predicting positive outcomes: changes in number of proximal refluxeschange from baseline number of proximal refluxes at 6 monthsparameter detected by 24hours esophagel impedance. pH-metric and impedance parameters are indicators of procedure effectiveness as able to quantify the presence of gastro-esophageal reflux.
To identify endoscopic factors predicting positive outcomes: changes in hiatal hernia sizechange from baseline hiatal hernia size at 6 monthsEndoscopic fundoplication with MUSE modifies the anatomy of the esophago-gastric junction to reduce the reflux of gastric contents into the esophagus. The size of a hiatal hernia is a parameter describing the continence characteristics of the sphincter neo-valve.
To identify pathophysiological factors predicting positive outcomes: changes in PSPW (Post Swallow reflux-induced Peristaltic Waves)change from baseline PSPW at 6 monthsparameter detected by 24hours esophagel impedance. pH-metric and impedance parameters are indicators of procedure effectiveness as able to quantify the presence of gastro-esophageal reflux.
To identify pathophysiological factors predicting positive outcomes: changes in BCT (Bolus Clearance Time)change from baseline BCT at 6 monthsparameter detected by 24hours esophagel impedance. pH-metric and impedance parameters are indicators of procedure effectiveness as able to quantify the presence of gastro-esophageal reflux.
To identify pathophysiological factors predicting positive outcomes: changes in LES (Lower Esophageal Sphincter) basal pressurechange from baseline LES basal pressure at 6 monthsparameter detected by High Resolution Esophageal Manometry (HRM). The manometric parameters describe the continence characteristics of the sphincter neo-valve and changes in esophageal motility after the intervention.
To identify pathophysiological factors predicting positive outcomes: changes in LES (Lower Esophageal Sphincter) lenghtchange from baseline LES lenght at 6 monthsparameter detected by High Resolution Esophageal Manometry (HRM). The manometric parameters describe the continence characteristics of the sphincter neo-valve and changes in esophageal motility after the intervention.
To identify pathophysiological factors predicting positive outcomes: changes in LES (Lower Esophageal Sphincter) IRP (Integrated Relaxation Pressure)change from baseline LES IRP at 6 monthsparameter detected by High Resolution Esophageal Manometry (HRM). The manometric parameters describe the continence characteristics of the sphincter neo-valve and changes in esophageal motility after the intervention.
To identify pathophysiological factors predicting positive outcomes: changes in DCI (Distal Contractile Integral)change from baseline DCI at 6 monthsparameter detected by High Resolution Esophageal Manometry (HRM). The manometric parameters describe the continence characteristics of the sphincter neo-valve and changes in esophageal motility after the intervention.
To identify pathophysiological factors predicting positive outcomes: changes in rate of peristaltic waveschange from baseline rate of peristaltic waves at 6 monthsparameter detected by High Resolution Esophageal Manometry (HRM). The manometric parameters describe the continence characteristics of the sphincter neo-valve and changes in esophageal motility after the intervention.
To identify pathophysiological factors predicting positive outcomes: changes in rate of weak waveschange from baseline rate of weak waves at 6 monthsparameter detected by High Resolution Esophageal Manometry (HRM). The manometric parameters describe the continence characteristics of the sphincter neo-valve and changes in esophageal motility after the intervention.
To identify pathophysiological factors predicting positive outcomes: changes in rate of fragmented waveschange from baseline rate of fragmented waves at 6 monthsparameter detected by High Resolution Esophageal Manometry (HRM). The manometric parameters describe the continence characteristics of the sphincter neo-valve and changes in esophageal motility after the intervention.
To identify pathophysiological factors predicting positive outcomes: changes in rate of failed waveschange from baseline rate of failed waves at 6 monthsparameter detected by High Resolution Esophageal Manometry (HRM). The manometric parameters describe the continence characteristics of the sphincter neo-valve and changes in esophageal motility after the intervention.
To identify pathophysiological factors predicting positive outcomes: changes in MNBI (Mean Nocturnal Baseline Impedance)change from baseline MNBI at 6 monthsparameter detected by 24hours esophagel impedance. pH-metric and impedance parameters are indicators of procedure effectiveness as able to quantify the presence of gastro-esophageal reflux.
To identify endoscopic factors predicting positive outcomes: changes in Hill's gradechange from baseline Hill's grade at 6 monthsEndoscopic fundoplication with MUSE modifies the anatomy of the esophago-gastric junction to reduce the reflux of gastric contents into the esophagus. The Hill's grade is a parameter describing the continence characteristics of the sphincter neo-valve. The Hill's grade range from I to IV; the higher grades represents worse outcomes (worse valve's continence).
To identify endoscopic factors predicting positive outcomes: changes in Jobe's lenghtchange from baseline Jobe's lenght at 6 monthsEndoscopic fundoplication with MUSE modifies the anatomy of the esophago-gastric junction to reduce the reflux of gastric contents into the esophagus. The Jobe's lenght is a parameter describing the continence characteristics of the sphincter neo-valve.

Countries

Italy

Contacts

Primary ContactPier Alberto Testoni, Professor
testoni.pieralberto@hsr.it+390226432756

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 20, 2026