Skip to content

Growth of High-Quality Oxides on The Inner Surface of ECMO Circuit by ALD to Reduce Thrombus Formation

Growth of High-Quality Oxides on The Inner Surface of ECMO Circuit by Atomic Layer Deposition to Reduce Thrombus Formation

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03662594
Enrollment
4
Registered
2018-09-07
Start date
2018-03-10
Completion date
2018-04-10
Last updated
2018-09-07

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Anticoagulation

Keywords

Anticoagulation

Brief summary

This study evaluate thermal ALD (T-ALD) and plasma-enhance ALD (PE-ALD) processes modified cardiopulmonary bypass (CPB) tubing to investigate anticoagulation properties.

Detailed description

ECMO is a technique which is currently being used worldwide for providing life support for patients experiencing both pulmonary and cardiac failure. Though ECMO can effectively rescue life at the initial scene, being invasive, complex, resource intensive, and serious related complications developing on the following days of ECMO support have greatly restricted it use. The major causes of ECMO-related mortality and morbidity are serious coagulopathy, either bleeding (7-34%) or thrombosis (8-17%). Contact of high extracorporeal blood flow and the large artificial surfaces plays a critical role leading to the subsequent coagulopathy. Systemic heparin and heparin-bonded circuits is usually used to reduce thrombus. However, non-urgent invasive procedures should be avoided or minimized during that support and regular clinical monitoring to guide the adjustment of optimal dosage is mandatory making the clinical care intensive. Whereas the pharmacological interventions may bring the risk of critical imbalance between hemostasis and thrombosis, efforts to modify the ECMO system focusing on improvement of biocompatibility seem a fundamental way particularly regarding the extended periods of ECMO use. ZrO2 and Al2O3 are more excellent biocompatible and hemocompatible materials compared with PVC (polyvinylchloride) which is the current material of ECMO circuit. Despite the broad applications of ZrO2 and Al2O3 in artificial implants, traditional thin-film coating techniques are unable to deposit these hemocompatible oxides on the inner surface of the PVC tubing in ECMO circuit. In this subproject, the investigators will apply a new technique of atomic layer deposition (ALD) to coat biocompatible and hemocompatible ZrO2/Al2O3 nanolaminate thin films on the inner surface of ECMO tubing to suppress the device-induced coagulopathy. ALD is a thin-film deposition technique for preparing high-quality oxides with atomic-layer accuracy. It offers many benefits including accurate thickness control, excellent conformality, high uniformity, low defect density, good reproducibility, and low deposition temperature. These characteristics clearly accounts for the feasibility to deposit high-quality hemocompatible oxide thin films on the whole surface of complex 3-D structures, such as the inner surface of ECMO tubing, using the ALD technique. The newly-prepared ECMO circuit will then undergo in vitro tests and animal study to carefully examine the safety and effectiveness of improvement of hemocompatibility.

Interventions

OTHERECMO

In this project, the investigators will apply a new technique of atomic layer deposition (ALD) to coat biocompatible and hemocompatible ZrO2/Al2O3 nanolaminate thin films on the inner surface of ECMO tubing to suppress the device-induced coagulopathy. ALD is a thin-film deposition technique for preparing high-quality oxides with atomic-layer accuracy. It offers many benefits including accurate thickness control. These characteristic clear accounts of the high-quality hemocompatible oxide thin films on the whole surface of complex 3-D structures, such as the inner surface The newly-prepared ECMO circuit will then undergo in vitro tests and animal study to carefully examine the safety and effectiveness of improvement of hemocompatibility.

Sponsors

National Taiwan University Hospital
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
SUPPORTIVE_CARE
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
20 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Adults * Weighing more than 50 kg

Exclusion criteria

* Pregnancy * Smoking * Chewing betel nut * History of any blood or cancer * Taking anticoagulants

Design outcomes

Primary

MeasureTime frameDescription
Protein content or configuration changedWithin 3 days after blood drawedUse ELISA to measuring the content or configuration of a protein when blood contact material, such as human serum albumin and human plasma fibrinogen etc.

Countries

Taiwan

Outcome results

None listed