Effect of Lateral Positioning on Bronchial Cuff Pressure of Left-sided Double-lumen Endotracheal Tube During Thoracic Surgery

Effect of Lateral Positioning on Bronchial Cuff Pressure of Left-sided Double-lumen Endotracheal Tube During Thoracic Surgery: a Prospective Observational Study

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03656406
Enrollment
74
Registered
2018-09-04
Start date
2018-09-01
Completion date
2019-12-30
Last updated
2020-08-06

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Lung Cancer, Pneumothorax

Keywords

Double-lumen endotracheal tube, Cuff pressure

Brief summary

The investigators evaluate the effect of postural change on the bronchial cuff pressure (BCP) of double-lumen endotracheal tube (DLT) in patients undergoing thoracic surgery, by observing the pressure of the bronchial cuff before and after lateral decubitus positioning.

Detailed description

It is essential to maintain proper cuff pressure in the endotracheal tube (ETT) when placing the ETT in the trachea in patients undergoing general anesthesia. Most of the literature recommend maintaining a pressure of 20-30 cmH2O to prevent cuff-related complications such as micro-aspiration or airway trauma. Proper pressure is also important for DLTs used in thoracic surgery. Furthermore, the cuff pressure of the ETT can change during the patient's positional changes. All things considered, we hypothesized that the change from supine to lateral decubitus position, which is essential for thoracic surgery would affect the BCP of the DLT.

Interventions

After the DLT intubation, the patient is placed in lateral decubitus position

DEVICECuff-manometer

The pressure of the bronchial cuff should be measured with cuff-manometer in supine position, and then measurement should be repeated after lateral positioning.

Sponsors

Research Institute of Medical Science, Daegu Catholic University
CollaboratorUNKNOWN
Daegu Catholic University Medical Center
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 70 Years
Healthy volunteers
Yes

Inclusion criteria

1. American Society of Anesthesiologists (ASA) physical status 1 or 2 2. Elective lung surgery requiring lateral decubitus positioning and one-lung ventilation using left-sided DLT

Exclusion criteria

1. Patients requiring a right-sided DLT. 2. Patients with an intraluminal lesion in the left mainstem bronchus (LMB). 3. Patients with an anatomical problem in the tracheobronchial tree. 4. Patients with impaired lung such as chronic obstructive pulmonary disease. 5. Patients who refused to participate in this study.

Design outcomes

Primary

MeasureTime frameDescription
Change of the maximum bronchial cuff pressure (BCP) which does not exceed 40 cmH2O with no air leak from supine to lateral decubitus position1. In supine position, 2 minutes after the completion of confirming the double-lumen endotracheal tube (DLT) position via fiberoptic bronchoscope (FOB) 2. In lateral position, 2 minutes after the completion of confirming the DLT position via FOBA cuff-manometer will be connected to the valve of the pilot balloon of bronchial cuff via a three-way stopcock. And then, the BCP will be assessed, while inflating the cuff with air in 0.5 ml increments from 0 to 3.0 ml. If the BCP exceeds 40 cmH2O during expansion by increasing 0.5 ml from 0 to 3.0 ml, we will stop inflating the bronchial cuff with air and record the bronchial cuff volume (BCV) and BCP up to the last numerical value. During the pressure measurement, air leak or seal around the bronchial cuff will be assessed at each time point when inflating the cuff in 0.5 ml increments.

Secondary

MeasureTime frame
The incidence of the patients whose maximum BCP exceed 40 cmH2O after lateral positioning1. In supine position, 2 minutes after the completion of confirming the DLT position via FOB 2. In lateral position, 2 minutes after the completion of confirming the DLT position via FOB
The minimum BCV that is the smallest bronchial cuff volume without air leakage1. In supine position, 2 minutes after the completion of confirming the DLT position via FOB 2. In lateral position, 2 minutes after the completion of confirming the DLT position via FOB