Skip to content

Video-assisted Telephone CPR With the EmergencyEye-Software - a Pilot Study - Proof of Concept

Video-assisted Telephone CPR With the EmergencyEye-Software - a Pilot Study - Proof of Concept

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03654846
Enrollment
54
Registered
2018-08-31
Start date
2018-08-25
Completion date
2018-09-30
Last updated
2018-10-04

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cardiac Arrest

Brief summary

Technical advance as broad-bandwidth wireless internet coverage and the ubiquity utilization of smartphones has opened up new possibilities which surpass the normal audio-only telephony. High quality and real-time video-telephony is now feasible. However until now this technology hasn't been deployed in the emergency respond service. In the hope of helping the detection of the cardiac arrest, offer the possibility to evaluate and correct via a video-instructed CPR (V-CPR) and to facilitate a fast localization of the emergency site, a new software (EmergencyEye®/RAMSES®) was developed which enables the dispatcher a video-telephony with the callers mobile terminal (smartphone) if suitable. This technology hasn't been tested in a randomized controlled trial in real environment conditions yet. This is to be done in this study.

Detailed description

Technical advance as broad-bandwidth wireless internet coverage and the ubiquity utilization of smartphones has opened up new possibilities which surpass the normal audio-only telephony. High quality and real-time video-telephony is now feasible. However until now this technology hasn't been deployed in the emergency respond service. In the hope of helping the detection of the cardiac arrest, offer the possibility to evaluate and correct via a video-instructed CPR (V-CPR) and to facilitate a fast localization of the emergency site, a new software (EmergencyEye®/RAMSES®) was developed which enables the dispatcher a video-telephony with the callers mobile terminal (smartphone) if suitable, and automated localisation of the caller. This technology hasn't been tested in a randomized controlled trial in real environment conditions yet. This is to be done in this study.

Interventions

DEVICEEmergencyEye

EmergencyEye Smartphone App

Sponsors

University of Cologne
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
OTHER
Masking
SINGLE (Caregiver)

Intervention model description

Test of EmergencyEye functionality in real environment, comparison with conventional emergency call.

Eligibility

Sex/Gender
ALL
Age
18 Years to 65 Years
Healthy volunteers
Yes

Inclusion criteria

* healthy volunteers

Exclusion criteria

* cardiovascular diseases * pulmonary diseases * pregnancy * all other conditions that make CPR impossible

Design outcomes

Primary

MeasureTime frameDescription
Recognition of CPR quality through video transmission1 minute of CPRRecognition of CPR quality (3 conditions are randomized in each CPR, i.e. Frequency, Compression Depth, Compression Point) in Video-assisted CPR

Secondary

MeasureTime frameDescription
Time to first chest compressionStudy duration (approx. 1 minute)Time measured from the beginning of the emergency call to the first chest compression
Precision of GeolocalisationStudy duration (approx. 1 minute)Precision of Geolocalisation, i.e. difference between verbally localized and automatically localized (aGPS) respondes to emergency call. Difference in runtimes of dispatched ambulances will be calculated

Countries

Germany

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026