INVSENSOR00027 Clinical Performance Study

INVSENSOR00027 Clinical Performance Study

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03650192
Enrollment
40
Registered
2018-08-28
Start date
2018-08-15
Completion date
2018-09-18
Last updated
2021-01-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Healthy

Brief summary

This study assesses the investigational sensor's (INVSENSOR00027) performance for detection of subjects' position and posture in bed, along with heart rate and respiratory rate.

Interventions

Investigational, noninvasive sensor that will be placed on the subject's chest and/or back. INVSENSOR00027 measures signals regarding subject's movement and posture, heart rate, and respiratory rate.

Sponsors

Masimo Corporation
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
OTHER
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
Yes

Inclusion criteria

* 18 to 80 years old * Physical status of ASA I or II * Subjects must be able to read and communicate in English * Has signed all necessary related documents, e.g. written informed consent, volunteer payment form, confidentiality agreement * Has completed Health Assessment Questionnaire and passed health assessment screening

Exclusion criteria

* Subject has any medical condition which in the judgment of the investigator, renders them inappropriate for participation in this study * Inability to tolerate sitting still or minimal movement for at least 30 minutes * Nursing female volunteers * Excluded at the Principal Investigator's discretion * Refusal to take the pregnancy test (for female subjects) * Positive pregnancy test for female subjects of child bearing potential. This is done for the safety of this population. * Refusal to shave hair (neck, chest) off areas where sensors will be applied (male subjects)

Design outcomes

Primary

MeasureTime frameDescription
Sensitivity of INVSENSOR00027's Posture Change Detection1-5 hoursFor each subject's position detection, INVSENSOR00027 output will be compared against observer's notes at each turn of the subject. Correctly detected position changes will be marked as True Positive. Missed detections (if any) will be counted. The sensitivity of INVSENSOR00027's posture change detection will be computed as Sensitivity = True Positive/(True Positive+Missed Detection)
Sensitivity of INVSENSOR00027's Activity Change Detection1-5 hoursFor each subject's activity (e.g., walking and upright) detection, INVSENSOR00027 output will be compared against observer's notes. Correctly detected activity changes will be marked as True Positive. Missed detections (if any) will be counted. The sensitivity of INVSENSOR00027's activity change detection will be computed as Sensitivity = True Positive/(True Positive+Missed Detection).
Sensitivity of INVSENSOR00027's Fall Event Detection1-5 hours

Secondary

MeasureTime frameDescription
Respiratory Rate Detection1-5 hoursAccuracy will be determined by comparing the respiratory rate measurement of the INVSENSOR00027 to the respiratory rate reference (RRef) and calculating the arithmetic root mean square (Arms) value. In order to obtain the Arms value, the RR measurement from the reference is subtracted from the INVSENSOR00027 RR measurement for a number of samples. The average of this difference is computed as the bias. The standard deviation of the differences is computed as the precision. The square root of the sum of the squares of bias and precision is computed as the Arms value.

Countries

United States

Participant flow

Participants by arm

ArmCount
INVSENSOR00027 Test Group
The subjects will be enrolled into the test group and will receive the INVSENSOR00027 investigational sensor. INVSENSOR00027: Investigational, noninvasive sensor that will be placed on the subject's chest and/or back. INVSENSOR00027 measures signals regarding subject's movement and posture, heart rate, and respiratory rate.
40
Total40

Baseline characteristics

CharacteristicINVSENSOR00027 Test Group
Age, Categorical
<=18 years
0 Participants
Age, Categorical
>=65 years
2 Participants
Age, Categorical
Between 18 and 65 years
38 Participants
Race/Ethnicity, Customized
African American
11 Participants
Race/Ethnicity, Customized
Asian or Pacific Islander
4 Participants
Race/Ethnicity, Customized
Caucasian
18 Participants
Race/Ethnicity, Customized
Hispanic
4 Participants
Race/Ethnicity, Customized
Native American
1 Participants
Race/Ethnicity, Customized
Other
2 Participants
Region of Enrollment
United States
40 participants
Sex: Female, Male
Female
22 Participants
Sex: Female, Male
Male
18 Participants

Adverse events

Event typeEG000
affected / at risk
deaths
Total, all-cause mortality
0 / 40
other
Total, other adverse events
0 / 40
serious
Total, serious adverse events
0 / 40

Outcome results

Primary

Sensitivity of INVSENSOR00027's Activity Change Detection

For each subject's activity (e.g., walking and upright) detection, INVSENSOR00027 output will be compared against observer's notes. Correctly detected activity changes will be marked as True Positive. Missed detections (if any) will be counted. The sensitivity of INVSENSOR00027's activity change detection will be computed as Sensitivity = True Positive/(True Positive+Missed Detection).

Time frame: 1-5 hours

ArmMeasureValue (NUMBER)
INVSENSOR00027 Test GroupSensitivity of INVSENSOR00027's Activity Change Detection96.7 percent sensitivity for posture change
Primary

Sensitivity of INVSENSOR00027's Fall Event Detection

Time frame: 1-5 hours

Population: Fall detection was an optional event per protocol.

ArmMeasureValue (NUMBER)
INVSENSOR00027 Test GroupSensitivity of INVSENSOR00027's Fall Event Detection100 percent sensitivity for fall detection
Primary

Sensitivity of INVSENSOR00027's Posture Change Detection

For each subject's position detection, INVSENSOR00027 output will be compared against observer's notes at each turn of the subject. Correctly detected position changes will be marked as True Positive. Missed detections (if any) will be counted. The sensitivity of INVSENSOR00027's posture change detection will be computed as Sensitivity = True Positive/(True Positive+Missed Detection)

Time frame: 1-5 hours

ArmMeasureValue (NUMBER)
INVSENSOR00027 Test GroupSensitivity of INVSENSOR00027's Posture Change Detection100 percent sensitivity for posture change
Secondary

Respiratory Rate Detection

Accuracy will be determined by comparing the respiratory rate measurement of the INVSENSOR00027 to the respiratory rate reference (RRef) and calculating the arithmetic root mean square (Arms) value. In order to obtain the Arms value, the RR measurement from the reference is subtracted from the INVSENSOR00027 RR measurement for a number of samples. The average of this difference is computed as the bias. The standard deviation of the differences is computed as the precision. The square root of the sum of the squares of bias and precision is computed as the Arms value.

Time frame: 1-5 hours

Population: 2 subjects were excluded due to data collection issues.

ArmMeasureValue (NUMBER)
INVSENSOR00027 Test GroupRespiratory Rate Detection1.7 A(RMS) of breaths per minute