End Stage Renal Failure on Dialysis
Conditions
Brief summary
The purpose of this study is to evaluate the complication of the puncture related complication in AVG (arteriovenous graft) such as pseudoaneurysm and hematoma, and the dialysis adequacy using plastic cannula versus metal needle in hemodialysis patients
Detailed description
1. Ultrasonography is performed to determine the maturity of vascular access 4 weeks after AVG creation. 2. The first puncture is performed with plastic cannula or metal needle when it is judged that the blood vessel has matured. 3. Four skilled nurses perform vascular access puncture with plastic or metal needle 4. Ultrasound are used to evaluate and record the complications related to the puncture in plastic or metal needle group every month. 5. Complications and dialysis adequacy between the two groups will be evaluated after 6 months
Interventions
puncture using plastic cannula
Sponsors
Study design
Intervention model description
Parallel Assignment
Eligibility
Inclusion criteria
* Patients receiving hemodialysis treatment using AVG
Exclusion criteria
* Age under 20 years old or over 75 years old * Abnormal skin condition using immunosuppressants such as steroids. * Skin disorder * Metal allergy
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| Incidence of pseudoaneurysm | Incidence of pseudoaneurysm at 6 months | critical puncture related complication in AVG |
Secondary
| Measure | Time frame | Description |
|---|---|---|
| punctutre related complication | Monthly for 6 months. | hematoma, inflitration, thrombus |
| Dialysis adeqaucy | Monthly for 6 months. | Kt/V by serum test in two groups |
Countries
South Korea