Evaluation of Device Settings for Airway Clearance Using The Monarch Airway Clearance System

Evaluation of Device Settings for Airway Clearance Using The Monarch Airway Clearance System

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03645473
Acronym
HFCWO
Enrollment
10
Registered
2018-08-24
Start date
2019-01-24
Completion date
2019-04-12
Last updated
2018-12-31

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cystic Fibrosis

Brief summary

The study will be an open label laboratory study with all subjects receiving HFCWO with The Monarch® System Objective: Assess device settings and to identify frequency/pressure (intensity) combinations that produce high airflow and oscillating volume Methodology: Subjects will receive HFCWO using The Monarch® System at multiple frequency / intensity combinations on a single visit day. Frequency / intensity combinations will be evaluated to determine which settings produce highest airflow and highest oscillating volume.

Detailed description

The study will be an open-label, laboratory study. All enrolled subjects will receive HFCWO therapy with the Monarch® system. The study will be conducted at one (1) site in the US. The study will evaluate oscillating airflow and oscillating volume induced during therapy with the Monarch® system. Subjects will also rate the comfort of the therapy. Patients with cystic fibrosis (CF) who meet all of the inclusion criteria and none of the exclusion criteria will be enrolled in the study. Therapy with the Monarch® system will be delivered using multiple frequency/intensity combination settings. The order of settings will be randomized for each study subject. During therapy oscillating flow and volume measurements will be obtained for each frequency/intensity combination. Following each frequency/intensity combination, subjects will respond to a subjective assessment of the comfort of the therapy by rating the comfort on a visual analogue scale (VAS).

Interventions

DEVICEMonarch Airway Clearance System

HFCWO Airway Clearance Device

Sponsors

Hill-Rom
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DEVICE_FEASIBILITY
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
15 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Documented diagnosis of CF (by sweat test and/or genetics * Age \> 15 years * Require regular home airway clearance therapy * Current user of The Monarch® System with a minimum of 4 weeks experience with the device * Signed informed consent. If patient is a minor, parents/guardians must give written informed consent and patient must give written assent * Patient must be on a stable regimen of CF medication

Exclusion criteria

* History of pneumothorax within the past 6 months prior to study visit * History of hemoptysis requiring embolization within the past 12 months prior to study visit or hemoptysis of \> 100 ml within a 24-hour period within the past 30 days * History of lobectomy * Recent chest surgery or chest trauma * Inability to perform The Monarch® System therapy as directed * Pregnant or lactating female * Have a pacemaker or implantable cardioverter defibrillator (ICD) * Requirement for oral or IV antibiotics that are not part of the subject's usual course of treatment within the past 14 days prior to screening

Design outcomes

Primary

MeasureTime frameDescription
Peak oscillating expiratory airflow measurements4-6 hoursSubjects will be treated with the Monarch® system using multiple frequency/intensity combination settings. After adjusting the therapy to the desired setting, subjects will be instructed breath through the mouthpiece for the flow measurement system, to breathe normally and continue relaxed breathing. Oscillating flow and volume measurement will be captured by the system over a period of 30 to 60 seconds of relaxed breathing. Data from the measurement of oscillating flow for each frequency/intensity combination setting will be processed following the completion of the testing

Secondary

MeasureTime frameDescription
Oscillating volume4-6 hoursOscillating volume measurement will be conducted concurrently with the measurement of flow. Subjects will be treated with the Monarch® system using multiple frequency/intensity combination settings as described above. Data from the measurement of oscillating volume for each frequency/intensity combination setting will be processed following the completion of the testing
Patient comfort/discomfort evaluated by 100 mm visual analogue scale (VAS)4-6 hoursFollowing the completion of testing for each frequency/intensity combination setting, subjects will rate the level of comfort/discomfort of the setting on a VAS. A Visual Analogue Scale is a psychometric response scale which will be used as a measuring instrument for subjective comfort or discomfort. It is a measurement instrument that ranges across a continuum of values and used to measure the intensity or frequency of various symptoms. * The Visual Analogue Scale ranges from (0 to 100 mm). * Zero means very uncomfortable/intolerable and 100 means very comfortable. The subject will mark the line for each setting combination to indicate the level of comfort or discomfort. After the Study visit, the research staff will measure the mark on the line and document the value.