Implantable MyoElectric Sensors (IMES) for Prosthetic Control in Transhumeral Amputees

Implantable MyoElectric Sensors (IMES) for Prosthetic Control in Transhumeral Amputees

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03644394
Acronym
TH-IMES
Enrollment
3
Registered
2018-08-23
Start date
2014-08-31
Completion date
2017-10-31
Last updated
2018-08-23

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Amputation

Brief summary

The Implantable Myoelectric Sensors (IMES) system is an investigational device intended to improve signal quality and consistency of myoelectric signals for prosthetic control in individuals suffering from an above elbow (transhumeral) amputation. The sensors pick up myoelectric signals intramuscularly and therefore signal quality is not affected from electrode replacement, perspiration, or artefacts.

Detailed description

Implantable Myoelectric Sensors (IMES), the surgical tools implantation, and the external equipment used to control an electromechanical prosthetic device, together comprise the IMES System (investigational product, medical device). Each IMES acts as an independent differential amplifier consisting of custom electronics housed within a biocompatible, hermetically sealed ceramic cylinder with metal end caps. The end caps serve as electrodes for picking up EMG activity during muscle contraction. Reverse telemetry (via a coil around the arm) is used to transfer data from the implanted sensor, and forward telemetry is used to transmit power and configuration settings to the sensors. The coil and associated electronics are housed within the frame of a prosthesis. A control system that sends data associated with muscle contraction to the motors of the prosthetic joints is housed in a belt-worn, battery-powered device. A cable attaches the control unit to the prosthetic frame. An IMES is implanted into each targeted muscle that will be used to control a function of the prosthetic arm. Two IMES devices are needed for each DOF. For example, one device would control fingers opening and another device would control fingers closing.

Interventions

DEVICEImplantation of IMES sensors

Surgical implantation of IMES sensors during routine surgery to improve prosthetic control

Sponsors

Medical University of Vienna
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DEVICE_FEASIBILITY
Masking
NONE

Eligibility

Sex/Gender
MALE
Age
16 Years to 70 Years
Healthy volunteers
No

Inclusion criteria

* unilateral transhumeral amputation * can speak and comprehend German * undergone amputee rehabilitation, including being trained to wear and use a conventional myoelectric prosthesis * residual upper limb meets the criterions for TMR surgery

Exclusion criteria

* Known genetic neuromuscular disorder * bleeding or clotting disorder * active implant * any metal fragments or metal implants located within the residual upper limb stump * Female patients if pregnant or breast-feeding

Design outcomes

Primary

MeasureTime frameDescription
Change in hand function over timeat 3, 6, 9 and 12 months after final prosthetic fittingSouthampton Hand Assessment Procedure

Outcome results

None listed