Skip to content

Clinical Investigation of the VytronUS Ablation System for Treatment of Paroxysmal Atrial Fibrillation

Clinical Investigation of the VytronUS Ablation System for Treatment of Paroxysmal Atrial Fibrillation - The VALUE Study

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03639597
Acronym
VALUE
Enrollment
53
Registered
2018-08-21
Start date
2016-01-18
Completion date
2018-12-31
Last updated
2019-04-24

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Paroxysmal Atrial Fibrillation

Keywords

ablation, ultrasound, automation, catheter

Brief summary

The study is a single center, open-label, single arm, prospective pre-market study designed to assess the safety and efficacy of the VytronUS Ablation System (VAS) for the treatment of atrial fibrillation in patients with drug refractory, recurrent, symptomatic, paroxysmal atrial fibrillation.

Detailed description

Subjects with documented symptomatic, recurrent, PAF refractory to at least one beta blocker, calcium channel blocker or Class I or Class III anti-arrhythmic drug, who meet all inclusion/exclusion criteria and are deemed appropriate candidates for catheter ablation will undergo PV ablation with the VAS. Pre-procedural CT scan or MRI will be obtained to assess LA and PV anatomy and size. PV ablation will be performed utilizing the VAS (see procedure description below). Acute post-ablation confirmation of PV electrical isolation will be evaluated via standard mapping techniques.

Interventions

Sponsors

VytronUS, Inc.
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 75 Years
Healthy volunteers
No

Inclusion criteria

1. Age between 18 and 75 years 2. History of symptomatic recurrent paroxysmal atrial fibrillation (PAF) in the prior year, defined by: a.Episodes of AF i.≥2 recurrent AF episodes of more than 30 seconds' duration that self-terminate and lasting no more than 7 continuous days or ii.Episodes of AF ≤ 48 hours duration terminated with electrical or pharmacologic cardioversion count as a paroxysmal atrial fibrillation episode b.At least one episode of paroxysmal atrial fibrillation (PAF) documented on 12-lead ECG, event monitor, or telemetry monitor in the prior year 3. Paroxysmal atrial fibrillation refractory to at least one Beta Blocker, Calcium Channel Blocker, or Class I or Class III anti-arrhythmic drug (AAD). 4. Subject is indicated for a pulmonary vein ablation according to society guidelines or investigational site practice. 5. Subject is able and willing to give informed consent. 6. Willingness, ability, and commitment to participate in baseline and follow-up evaluations for the full duration of the study.

Exclusion criteria

1. Non-paroxysmal AF (e.g. persistent, long-standing persistent, or permanent AF) 2. AF secondary to electrolyte imbalance, thyroid disease or reversible or non-cardiac cause. 3. Prior LA ablation or surgery 4. Women known to be pregnant or breastfeeding or of childbearing potential unless on satisfactory contraceptive routine 5. NYHA Class III or IV congestive heart disease 6. LVEF \<40% measured by acceptable cardiac testing (eg. TTE, TEE) 7. Anteroposterior LA diameter \>5.5cm or \<3.0cm by TTE 8. Presence of intracardiac thrombus (including a known history of thrombus) within 30 days prior to the index ablation procedure 9. Presence of pulmonary vein stent(s) 10. Presence of pre-existing pulmonary narrowing or pulmonary vein stenosis 11. Presence of a cardiac valve prosthesis 12. Bleeding diathesis or contraindication to anticoagulation therapy 13. Blood clotting abnormalities (genetic) 14. MI, PCI, invasive cardiac procedure or surgery within 90 days prior to the index ablation procedure 15. Previous CVA, TIA, or PE within 3 months prior to the index procedure 16. Structural heart defect that, in the investigator's opinion, prevents catheter access or increases risk of ablation procedure 17. Pacemaker, ICD, or CRT implantation within 6 months prior to the index ablation procedure 18. Active systemic infection 19. Subject contraindicated for both MRI and CT 20. Life expectancy less than 360 days in physician's opinion 21. Participation in a drug or device study 22. Exclusion as per local laws -

Design outcomes

Primary

MeasureTime frameDescription
Primary Efficacy - Acute success and chronic freedom from AF, AFL and AT lasting longer than 30 seconds, freedom from new class I or II AAD12 monthsAcute (or technical) procedural success defined as PVI documented by confirmed entrance block. Chronic success defined by freedom from symptomatic AF, AT and AFL lasting longer than 30 seconds, freedom from new class I or II AAD and no repeat ablation through 12 months of follow-up.
Primary Safety - incidence of acute AEs occurring within 7 days of procedure and chronic adverse events12 monthsAcute major AEs occurring within 7 days of procedure and chronic AEs defined as symptomatic PV stenosis \>70% or symptomatic atrio-esophageal fistula diagnosed within 12 months.

Countries

Czechia

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 19, 2026