Skip to content

Transbronchial Lung Biopsy Guided by ENB

Transbronchial Lung Biopsy Guided by Electromagnetic Navigation Bronchoscopy: A Prospective, Randomized, Multicenter, Superiority Study

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03628222
Enrollment
226
Registered
2018-08-14
Start date
2019-01-04
Completion date
2020-08-10
Last updated
2024-08-23

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Lung Lesion(s) Requiring Evaluation

Keywords

Lung lesion, Electromagnetic navigation bronchoscopy (ENB), Transbronchial lung biopsy(TBLB), bronchoscopy

Brief summary

The purpose of this study is to evaluate the performance and safety of electromagnetic navigation bronchoscopy (ENB) system and system kit (iLungTM SuperNavigator) .

Detailed description

This is prospective, randomized, multicenter, superiority study. 8 top centers in China was chosen. Subject which has peripheral lung lesions (PLLs) detected by chest CT scan, requires biopsy diagnosis, and meets all inclusion and exclusion criteria, will be included in this trial. Firstly physician determines the lesion biopsied, then the subject will be randomized to experimental or control group. The experimental group is treated with ENB guided transbronchial lung biopsy (TBLB)(ENB-TBLB): Under ENB guidance, the location sensor reaches the edge of the lesion, and X-ray is used for actual distance confirmation, if physician determines the distance is enough for biopsy, TBLB will be conducted. The control group will be treated with TBLB using X-ray guidance.

Interventions

DEVICEENB-TBLB

ENB Guidance: The iLungTM SuperNavigator system will be used, it comprises of iLungTM ENB system, location catheter and guide catheter. The guide catheter can supply a 1.9 mm working channel for biopsy tools. The location catheter is inserted into the guide catheter beforehand, then both are introduced via the working channel of the bronchoscope. Under guidance of ENB system, the location catheter reaches the lesion, and actual distance is confirmed by the X-ray. TBLB: Location catheter is retracted, then the biopsy forceps and brush was introduced, and pathologic specimens are obtained.

DEVICEX-ray-TBLB

Based on chest CT, the physician determines the lesion location. Under X-ray guidance, via the bronchoscope's working channel, the biopsy forceps and brush are introduced and pathologic specimens are obtained.

Sponsors

Changzhou LungHealth Medtech Company Limited
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* 18 years and older; * Subject presents with PLL(s) detected by chest CT scan and biopsy diagnosis is needed; * Subject is willing to receive bronchoscopy voluntarily, and meets relevant requirements; * Subject or their guardian understands the purpose of this trial, and willing to participate in the trial voluntarily and sign Informed Consent Form (ICF).

Exclusion criteria

* Subject has participated in a drug or device study (drug study within 3 months or device study within 1 month); * Female subject who is pregnant or nursing; * Allergic to anesthetic; * Bronchoscopy contraindications, include: Active hemoptysis; Newly developed myocardial infarction or unstable angina attack; Severe cardiac and pulmonary dysfunction; Severe hypertension and arrhythmia; Uncorrectable bleeding tendency (Such as severe clotting dysfunction, uremia, and severe pulmonary hypertension, etc.); Severe superior vena cava obstructive syndrome; Suspected aortic aneurysm; Multiple lung bullae; Extremely exhausted systemic conditions; * Subject with serious lung disease (Such as: severe bronchiectasis, severe emphysema, etc) ,which investigator considers not appropriate for this examination; * Subject with implanted pacemaker or defibrillator; * Lack of patient cooperation for bronchoscopy, such as patient with mental disorders, dysgnosia, psychological disorder etc; * Conditions investigator considers not appropriate for this trial.

Design outcomes

Primary

MeasureTime frameDescription
Compare the diagnostic yield of ENB-TBLB with that of X-ray-TBLBUp to 6 monthsDiagnostic yield = Lesions with definitive diagnosis /total lesions with biopsies. Comment: Lesions with definitive diagnosis: 1. Biopsy pathologic results show as benign or malignant lesion (fungi, tuberculosis, or nodule disease,etc.); 2. Biopsy pathologic results are abnormal lung tissue, but through later diagnosis, treatment and other observation measures, the lesion is proved to be benign; 3. When the patient cannot be diagnosed after a 6-month following-up, a CT or enhanced CT scan is needed and the physician make a final diagnosis based on the scan results.

Secondary

MeasureTime frameDescription
Incidence of navigation successAt 1 day of ENB procedureThis outcome just apply to experimental group. Incidence of navigation success = the number of lesions navigated successfully/total lesions with ENB procedure × 100%. Criteria for navigation success: When the navigation software shows the distance of location sensor to the target ≤10mm, using X-ray to confirm the actual distance, if the physician determine that biopsy can be conducted, the navigation is successful, if not, the navigation fails.
Lesion detection rateAbout 3-7days after ENB or X-ray procedureBased on the biopsy pathologic results, evaluate the lesion detection rate of experimental and control group. Lesion detection rate = Total lesions detected / Total lesions with biopsies. Comment: 'Lesions detected' indicates pathologic result shows as abnormal lung tissue.
Navigation timeAt 1 day of ENB or X-ray procedureEvaluate navigation time of experimental and control group. Experimental group: After registration, the location sensor returns the carina. Navigation begins from the carina and ends when the sensor reaches the edge of the lesion, which is verified by the X-ray. This period is defined as navigation time of experimental group. Control group: Under X-ray guidance, the bronchoscope moves from the carina to the edge of the lesion. This period is defined as navigation time of control group.
Evaluate the user satisfaction of ENB system and system kitAt 1 day of ENB procedureAfter each ENB procedure, the investigator evaluate the operational performance of ENB system and system kit through a pre-designed questionnaire which includes terms related to the device function, convenience, reliability and safety.
The adverse events and device defects related to the ENB system and system kitUp to 3 daysAdverse events: Include incidence of pneumothorax, bleeding, respiratory failure, etc.

Countries

China

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026