Skip to content

Post Market Clinical Follow-up (PMCF) Study of the A.L.P.S. Proximal Humerus Plating System

A.L.P.S. Proximal Humerus Plating System Post-Market Clinical Follow-up Study

Status
Active, not recruiting
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03626038
Enrollment
135
Registered
2018-08-10
Start date
2018-06-19
Completion date
2026-12-01
Last updated
2026-02-13

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Osteoarthritis, Post-Traumatic Arthritis, Proximal Humeral Fracture, Psoriatic Arthritis, Rheumatoid Arthritis

Keywords

Trauma, Medical Device, Performance, Safety, Proximal Humeral Fracture

Brief summary

This study is a multicenter, prospective, non-randomized, non-controlled post-market clinical follow-up study. The primary objective of this study is to confirm the safety and performance of the A.L.P.S. Proximal Humerus Plating System applied in proximal humerus fracture treatment.

Detailed description

The A.L.P.S. Proximal Humerus Plating System was developed to provide another surgical option for proximal humerus fracture fixation. The aim of the A.L.P.S. Proximal Humerus Plating System is to provide increased fracture stability while simultaneously increasing range of motion and decreasing the likelihood of screw perforation. A minimum of 7 and maximum of 10 sites globally will be involved in this study. This number of clinical sites will allow for a better generalization of study data as well as allow for consistency to be developed across multiple regions. 135 implants will be included into the study. Each site will be allowed to enroll 27 humeri. Enrollment is competitive. All potential study subjects will be required to participate in the Informed Consent process.

Interventions

DEVICEA.L.P.S. Proximal Humerus Plating System

Anatomically contoured, locking plates that can be customized intra-operatively, multidirectional screws allow for stable fixation for a wide variety of patients.

Sponsors

Zimmer Biomet
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patient must be 18 years of age or older. * Patient must have a primary proximal humerus fracture (Orthopaedic Trauma Association/ American Orthopedic 11-A, B, C) requiring surgical intervention and be eligible for fixation by plate and screws. * Patients with failed conservative treatment within 3 weeks since injury. * Patient must be able and willing to complete the protocol required follow-up. * Patient must have a signed Institutional Review Board/Ethics Committee approved informed consent. * Patient must be in a good nutritional state

Exclusion criteria

* Delay of surgery for more than 3 weeks. * Tumor induced fractures * Patient is a prisoner. * Pregnancy/ breast feeding * Patient is a current alcohol or drug abuser. * Patient has a mental or neurologic condition that will not allow for proper informed consent and/or participation in follow-up program. * Patient has an active infection. * Patient conditions including limitations in blood supply, obesity, or insufficient quantity or quality of bone stock. * Patient is sensitive to foreign body material.

Design outcomes

Primary

MeasureTime frameDescription
Re-operation1 yearRe--operation within the first year post-initial surgery due to screw perforation of the humeral head, secondary displacement or impingement to relieve pain and/or improve function.

Secondary

MeasureTime frameDescription
Clinical efficacy of the device is assessed using the American Shoulder and Elbow Surgeon Patient Questionnaire2 yearsPain, function and activities of daily living are measured. The American Shoulder and Elbow Surgeon (ASES) scale is 0 to 100. 100 is the highest score and indicates the greatest function while 0 is the lowest score.
Shoulder range of motion measurement2 yearsShoulder range of motion is assessed in degrees of directional movement. This will be measured during a physical exam by the investigator. Values measured include active and passive range of motion.
Clinical performance of the device is assessed using x-ray capture2 yearsX-ray capture will be used to analyze fracture healing

Countries

Australia, Canada, South Korea, Switzerland, United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 14, 2026