Skip to content

Efficacy and Safety of Argon Plasma Coagulation in the Treatment of Patients With Hemoptysis Caused by Endobronchial Malignancies

Prospective, Observational Study on the Efficacy, the Safety and the Predictors of Success of Argon Plasma Coagulation in the Treatment of Patients With Hemoptysis Caused by Endobronchial Malignancies

Status
Terminated
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03625947
Enrollment
75
Registered
2018-08-10
Start date
2018-08-08
Completion date
2023-07-15
Last updated
2023-08-01

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cancer, Hemoptysis

Keywords

Hemoptysis, Lung cancer

Brief summary

The aim of this study is to evaluate the efficacy, the safety and the main predictors of success of bronchoscopic Argon Plasma Coagulation in patients with hemoptysis caused by endobronchial malignancies.

Detailed description

Hemoptysis is a challenging symptom which may be frequently related to endobronchial malignancies. Patients with central neoplasms and hemoptysis show a lower median survival than patients with no bleeding and endobronchial neoplasms and/or patients with hemoptysis and peripheral malignant lesions. Hemoptysis control without recurrence at 48 hours after bronchoscopic interventions may improve survival in patients with mild bleeding and endobronchial malignancies. Argon Plasma Coagulation is considered one of the most effective techniques for endobronchial management of hemoptysis in this subset of patients. Nevertheless, few data are available in literature on its efficacy and safety, and the main predictors of success are still unclear. In this prospective, observational study, investigators aim to evaluate the efficacy (i.e. immediate bleeding cessation without recurrence during the following 48 hours) of endoscopic Argon Plasma Coagulation in patients with hemoptysis caused by endobronchial neoplasms. Investigators will also evaluate the safety of the procedure, the main variables associated to a successful intervention, the presence of hemoptysis relapses and patients overall survival to 3,5 months after the bronchoscopic intervention.

Interventions

Patients will be treated with Argon Plasma Coagulation. Argon plasma coagulation (APC) is a form of non contact electrocoagulation. APC utilizes electrically conductive argon plasma as a medium to deliver high-frequency current via a flexible probe. The argon plasma flow transfers electricity between the probe and the target tissue. Tracheobronchial access is obtained by passing the probe through the working channel of the bronchoscope. On arrival to the tissue, the application of energy causes uniform zones of desiccation, coagulation and devitalization in the areas receiving treatment, thus inducing hemostasis.

Sponsors

University of Milan
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Adult patients with hemoptysis caused by endobronchial (i.e. identifiable with flexible bronchoscopy) malignancies, without coagulopathy or other medically correctable causes of bleeding, who need endoscopic intervention with Argon Plasma Coagulation to stop bleeding * Adult patients who are able to tolerate bronchoscopy * Adult patients who are able to sign the written informed consent for the study participation

Exclusion criteria

* Patients with hemoptysis caused by endobronchial malignancies with coagulopathy or other medically correctable causes of bleeding. * Patients who are not able to tolerate bronchoscopy * Patients with hemoptysis without identifiable endobronchial malignancies during flexible bronchoscopy * Patients with Pace-Maker and/or Automated Implantable Cardioverter- Defibrillator(AICD) * Patients who refuse/are not able to sign the informed consent for the study participation

Design outcomes

Primary

MeasureTime frameDescription
Percentage of patients with bleeding cessation without recurrence at 48 after bronchoscopic Argon Plasma Coagulation48 hoursPercentage of patients with bleeding cessation without recurrence at 48 hours after bronchoscopic Argon Plasma Coagulation employed to stop hemoptysis caused by endobronchial malignancies

Secondary

MeasureTime frameDescription
Incidence of adverse events48 hoursIncidence of adverse events following bronchoscopic Argon Plasma Coagulation in the treatment of patients with hemoptysis and endobronchial malignancies
Incidence of hemoptysis recurrences3,5 monthsIncidence of hemoptysis recurrences (number of relapses)
Number of patients with hemoptysis and endobronchial malignancies who are still alive at the end of the follow-up3,5 monthsNumber of patients with hemoptysis and endobronchial malignancies who are still alive after 3,5 months after the endoscopic intervention
Clinical and endoscopic factors (composite measure) associated to bleeding cessation after the intervention48 hoursClinical and endoscopic factors (composite measure) associated to bleeding cessation after the intervention (i.e. age, gender, ethnicity, smoking history, cancer type and stage, ECOG performance Status, concomitant heart, lung, kidney and liver disease, antiplatelet/anticoagulant therapy, creatinine and hemoglobin level and platelet count, PT and PTT values; endoscopic location of malignancy (i.e. lobe and side), endoscopic growth pattern of malignancy (i.e. exophytic, submucosal/peribronchial growth), current/former chemotherapy and radiation therapy on the chest, time from malignancy diagnosis to hemoptysis onset, time from hemoptysis onset to endoscopic treatment, necessity of blood transfusion).

Countries

Italy

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026