The Validation of the FibriCheck Application for the Detection of Atrial Fibrillation

FLASH-AF: The Validation of the FibriCheck Application for the Detection of Atrial Fibrillation

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03620656
Acronym
FLASH-AF
Enrollment
300
Registered
2018-08-08
Start date
2018-09-01
Completion date
2019-09-15
Last updated
2019-12-26

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Atrial Fibrillation

Keywords

Atrial Fibrillation, FibriCheck, Validation, Smartphone, Smartwatch

Brief summary

Optical sensing technologies have the potential to enable long-term heart rhythm monitoring. The medically certified and clinically validated FibriCheck technology has proven its value for spot-check measurements to detect AF. However, further validation and verification of this technology is necessary to evaluate the performance of the FibriCheck technology on different tools (smartphones and smartwatches). During this study the performance of various optical sensors, ranging from the camera in smartphones to the photodetector in smartwatches, will be explored and device and form-factor variability will be investigated. The objective is to define the accuracy of optical sensing systems in the detection of atrial fibrillation versus a reference traditional 12-lead ECG signal.

Detailed description

During this study the performance of various optical sensors, ranging from the camera in smartphones to the photodetector in smartwatches, will be explored and device and form-factor variability will be investigated. The objective is to define the accuracy of optical sensing systems in the detection of atrial fibrillation versus a reference traditional 12-lead ECG signal. Therefore, 2 groups will be created where different technologies will be investigated i.e. Group 1 will use various mobile devices and Group 2 will use various wearable devices. The recruitment of patients will be carried out in the framework of the usual care practice, where patients can be recruited at different moments throughout their current care-cycle. Group 1: Smartphone based sensor: Here, the user needs to place the finger on the smartphone camera for 60 seconds to obtain high quality PPG waveforms. These waveforms are analysed using automated algorithms and stored under a unique anonymized study ID. Group 2: Smartwatch based sensor: Here, a wearable device is used that is placed on the wrist and will record a PPG signal, similar as the smartphone camera, but with a specific PPG sensor. The data is extracted and processed by the FibriCheck software and the algorithms generate a diagnostic output which is stored under a unique anonymized study ID. The hardware involved originates from different providers. Since FibriCheck is certified as stand-alone software, it is expected that it functions independently from different hardware sources. This hypothesis will be addressed in this study. Smartphone devices that will be used in this research: Samsung, Huawei, Xiaomi, Apple, LGE, Lenovo and ZTE devices. Wearable devices that will be used in this research: Apple and Fitbit smartwatch devices.

Interventions

DIAGNOSTIC_TESTFibriCheck

Photoplethysmography-based smartphone or smartwatch sensor to assess cardiac rhythm

Sponsors

Qompium NV
Lead SponsorINDUSTRY

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* 18 years or older

Exclusion criteria

* Pacemaker dependent heart rhythm * Tremor or Parkinson's disease * Barriers for communication and lack of capability to execute the handlings required for this study

Design outcomes

Primary

MeasureTime frameDescription
Diagnostic accuracy to identify atrial fibrillationJuly 2019Assessment of the diagnostic accuracy of the FibriCheck smartphone or smartwatch application to detect atrial fibrillation on devices with various technical aspects. The diagnostic accuracy will be determined by comparing the FibriCheck diagnosis with the diagnosis of a gold-standard 12-lead ECG. Differences in diagnostic accuracy of FibriCheck on different hardware devices will be evaluated.

Countries

Belgium

Outcome results

None listed