Skip to content

NVT ALLEGRA TAVI System TF in Failing Calcified Aortic Heart Valves in a Real-world Patient Population

Clinical Outcomes of the NVT ALLEGRA TAVI System TF in Failing Calcified Aortic Heart Valves in a Real-world Patient Population With Elevated Surgical Risk

Status
Active, not recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03613246
Acronym
FOLLOW
Enrollment
346
Registered
2018-08-03
Start date
2019-02-20
Completion date
2029-01-26
Last updated
2025-11-17

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Transcatheter Aortic Valve Implantation

Keywords

TAVI, Aortic valve stenosis, ALLEGRA

Brief summary

The study collects real-world data of patients who were treated with the ALLEGRA TAVI System TF and evaluates early and midterm clinical and quality of life outcome.

Interventions

None listed

Sponsors

NVT GmbH
Lead SponsorINDUSTRY

Study design

Observational model
OTHER
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Symptomatic degeneration of severe calcified aortic heart valve OR failing surgical aortic bioprosthetic valve 2. Acceptable candidate for elective treatment with the ALLEGRA TAVI System TF (according to the most recent version of the ALLEGRA Instructions For Use) 3. High risk for surgery as assessed by the heart team 4. Has signed the Patient Informed Consent Form \>= 18 years

Exclusion criteria

General: 1. Echocardiographic evidence of intracardiac thrombus or vegetation 2. Significant aortic disease such as severe obstructive calcification or marked tortuosity or kinking which will preclude a safe advancement of the ALLEGRA TAVI System TF 3. Iliofemoral vessel conditions such as severe obstructive calcification, severe tortuosity or kinking that would preclude safe placement of an 18 Fr introducer sheath or make endovascular access to the aortic valve impossible 4. Severe ventricular dysfunction with LVEF \<20% 5. Evidence of active endocarditis or other acute infections 6. Renal failure requiring continuous renal replacement therapy 7. Known hypersensitivity to contrast media, which cannot be adequately pre-medicated or contraindication to anticoagulant or anti-platelet medication or to nitinol alloy or to bovine tissue 8. Life expectancy ≤ 12 months due to other medical illness 9. Currently participating in another investigational drug or device study Patients with native aortic valve disease: 1. Unicuspid or bicuspid aortic valve 2. Non-calcified aortic stenosis 3. Combined aortic valve disease with predominant aortic regurgitation \> 3 4. Distance between aortic valve basal plane and the orifice of the lowest coronary artery \< 8 mm Patients with degenerated surgical bioprosthetic aortic valves: 1. Low position of the coronary ostia, especially in combination with shallow sinuses 2. Internal diameter of the bioprosthesis is ≤16 mm or \>28 mm 3. Partially detached leaflets that in the aortic position may obstruct a coronary ostium

Design outcomes

Primary

MeasureTime frame
Cardiovascular death30 days post-index procedure

Secondary

MeasureTime frameDescription
Technical success of implantationday of procedureTechnical success of implantation, as defined by: * absence of procedural mortality AND * correct positioning of a single prosthetic heart valve into the proper anatomical location AND * no prosthesis - patient mismatch AND * mean aortic valve gradient \<20 mmHg, AND * no moderate or severe prosthetic valve regurgitation
Assesment of NYHA classification30 days, 12 month, 24 month, 36 month, 48 month, 60 month
Safety profile according to VARC II30 daysEarly Safety * All-cause mortality * All stroke (disabling and non-disabling) * Life-threatening bleeding * Acute kidney injury-Stage 2 or 3 (including renal replacement therapy) * Coronary artery obstruction requiring intervention * Major vascular complication * Valve-related dysfunction requiring repeat procedure Time-related valve safety * Structural valve deterioration as defined by * Requiring repeat procedure (transcatheter or surgical heart valve replacement) * Valve-related dysfunction defined by * mean aortic valve gradient ≥20 mmHg and * no moderate or severe prosthetic valve regurgitation * Prosthetic valve endocarditis * Prosthetic valve thrombosis * Thrombo-embolic events (e.g. stroke) * VARC bleeding, unless clearly unrelated to valve therapy
All-cause mortalityup to five years
Quality of life (EQ5D 5L)30 days, 12 month, 24 month, 36 month, 48 month, 60 month
New pacemaker implantationup to five years
assessment of mean aortic gradient post-implantationup to five years
In-hospital mortalitydate of procedure till date of estimated discharge, assessed up to two weeks

Countries

Finland, Germany, Italy, Netherlands, Spain, United Kingdom

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026