Skip to content

Patient Specific Mitral Valve Modeling for Surgical Planning and Training

Patient Specific Mitral Valve Modeling for Surgical Planning and Training

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03609931
Enrollment
65
Registered
2018-08-01
Start date
2018-07-31
Completion date
2020-01-31
Last updated
2018-08-01

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Mitral Regurgitation, Mitral Valve Disease, Mitral Valve Prolapse

Keywords

Mitral Valve

Brief summary

Mitral valve disease is a common pathologic problem occurring in approximately 2% of the general population but climbing to 10% in those over the age of 75 in Canada\[1\]. This project has three primary goals all of which will positively affect cardiac patient care. 1\) Create patient specific MV models for complex repairs that will allow surgeons the opportunity to practice the repair. 2) Potentially predict the outcomes following minimally invasive repair techniques such as transcatheter treatments (e.g., MitraClip). 3) Provide a model to train individuals on mitral valve repair techniques.

Detailed description

BACKGROUND Mitral valve disease is a common pathologic problem occurring in approximately 2% of the general population, but climbing to 10% in those over the age of 75 in Canada. Of this group, approximately 20% have a sufficiently severe form of the disease that may require surgical intervention to restore normal valve function and prevent early mortality \[4\]. Evidence indicates that the surgeon's individual volume of mitral valve repair cases performed is a determinant of not only successful mitral repair rates, but also freedom from reoperation, and patient survival. For patients previously deemed inoperable due to co-morbidities, new techniques to treat mitral valve disease are being developed. However, assessing the optimal approach and the point at which clinical benefit is exceeded by the poor value or futility of the procedure is one of the biggest clinical challenges for physicians. In the past decade, 3D echocardiography has emerged as a standard of care in diagnostic and interventional imaging for cardiac surgery and cardiology. This, coupled with the emergence of inexpensive 3D printing technology has led researchers and clinicians to explore how improved imaging and additive manufacturing can be used to improve patient outcomes. In this context, the investigators have completed a proof-of-concept workflow for creating dynamic, patient specific mitral valve models. In concert with a left ventricle simulator 8\], these valve models can mimic patient valve pathologies both anatomically and dynamically, as shown in Doppler ultrasound. In a 10 patient retrospective study, the investigators have demonstrated the ability to accurately re-create patient pathology, perform realistic surgical repairs, and assess realistic valve function post repair. The study team's vision is to create a simulator that can be used to assess patient candidacy for percutaneous interventions, assess different repair options for both percutaneous and surgical interventions, and finally use the model as a simulator for competency-based MV interventions. RATIONALE Based on our successful proof of concept, the goal is to translate this technology to clinical use by validating our valve models. There are two primary long term goals. First, to validate a system for using patient specific MV models to: 1- assess intervention options, and 2: plan repair strategies for improved patient outcomes. Second, by building a database of MV pathologies, create a competency based simulator/trainer to provide surgeons with increased experience in MV repair techniques. OBJECTIVES 1. Validate the accuracy of patient specific MV pathologies and repairs in a prospective 65 patient study; 2. Optimize our work-flow for creating valve models, in terms of accuracy, manufacture time required, and expense; 3. Validate the accuracy of our patient models for both surgical cases and transcatheter MitraClip interventions;

Interventions

PROCEDUREMitral Valve Model

Creation of a mitral valve patient specific model to see if it mimics the patients valve

Sponsors

London Health Sciences Centre Research Institute OR Lawson Research Institute of St. Joseph's
Lead SponsorOTHER

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years

Inclusion criteria

* Patients undergo mitral valve repair with either surgery of MitraClip techniques * Over 18 years old

Exclusion criteria

* Unable to place TEE probe * Refuse consent

Design outcomes

Primary

MeasureTime frameDescription
MR following patient/model repairCreation and assessment of the model within 1 week before or after surgery/intervention on the patient.The degree and location of residual MR following mitral repair surgery

Secondary

MeasureTime frameDescription
2D measurements of the mitral valve:Annular HeightAssessment of model within 1 week of surgical or interventional repair on the patientA 2D measurements taken from the echocardiography images of the mitral valve and model
2D measurements of the mitral valve: Annular 3D CircumferenceAssessment of model within 1 week of surgical or interventional repair on the patientA 2D measurements taken from the echocardiography images of the mitral valve and model
2D measurements of the mitral valve:Annular 2D AreaAssessment of model within 1 week of surgical or interventional repair on the patientA 2D measurements taken from the echocardiography images of the mitral valve and model
2D measurements of the mitral valve: Annular EllipticityAssessment of model within 1 week of surgical or interventional repair on the patientA 2D measurements taken from the echocardiography images of the mitral valve and model
2D measurements of the mitral valve: Anterior Leaflet 3D AreaAssessment of model within 1 week of surgical or interventional repair on the patientA 2D measurements taken from the echocardiography images of the mitral valve and model
2D measurements of the mitral valve: Posterior Leaflet 3D AreaAssessment of model within 1 week of surgical or interventional repair on the patientA 2D measurements taken from the echocardiography images of the mitral valve and model
2D measurements of the mitral valve: Leaflet 3D AreaAssessment of model within 1 week of surgical or interventional repair on the patientA 2D measurements taken from the echocardiography images of the mitral valve and model
2D measurements of the mitral valve: Mitral Regurgitation Orifice AreaAssessment of model within 1 week of surgical or interventional repair on the patientA 2D measurements taken from the echocardiography images of the mitral valve and model
2D measurements of the mitral valve: Tenting VolumeAssessment of model within 1 week of surgical or interventional repair on the patientA 2D measurements taken from the echocardiography images of the mitral valve and model
2D measurements of the mitral valve: Anterolateral-Posteromedial DiameterAssessment of model within 1 week of surgical or interventional repair on the patientA 2D measurements taken from the echocardiography images of the mitral valve and model
2D measurements of the mitral valve: tenting Height.Assessment of model within 1 week of surgical or interventional repair on the patientA 2D measurements taken from the echocardiography images of the mitral valve and model
ICU LOSPostoperative period until ICU discharge (expected mean of 1 days)]length of stay in the ICU
Hospital LOSPostoperative period until hospital discharge (expected mean of 5 days)Length of stay in hospital
DeliriumPostoperative period until hospital discharge (expected mean of 5 days)Delirium in hospital
Renal failure requiring dialysisPostoperative period until hospital discharge (expected mean of 5 days)Dialysis
Stroke,TIAPostoperative period until hospital discharge (expected mean of 5 days)Diagnosis of stroke
Death in HospitalPostoperative period until hospital discharge (expected mean of 5 days)Death
Reoperation for BleedingPostoperative period until hospital discharge (expected mean of 5 days)Return to the operating room for re-exploration of the surgical procedure due to excess blood loss in the ICU
2D measurements of the mitral valve: Nonplanar AngleAssessment of model within 1 week of surgical or interventional repair on the patientA 2D measurements taken from the echocardiography images of the mitral valve and model

Contacts

Primary ContactDaniel Bainbridge, MD FRCPC
daniel.bainbridge@lhsc.on.ca5192004235

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026